Page 1 of 2 Lowprofile Direct Lens 3-Light T8 Per 4-Foot Section

Ordering Information
Style Type Mounting Length Total Lamps Color Ballast & Voltage
CD7 2 WH
2
= Direct Lens1 = Surface
Complete ordering instructions below.
= Cable
= Sfem
= Wall
4
= 4-foot
8
= 8-foot
For all fixtures represented in this family please refer to the brochure and/or additional specification sheets.
3
= 3-Lamp T8
per fixture
(4'fixture)
6
= 6-Lamp T8
per fixture (8' fixture)
White E81
E82 HD1
HD2
M71 M72
= T8 Electronic 120V = T8 Electronic 277V
=T8 Electronic PowerSpec®
HDE Dimming 120V
= T8 Electronic PowerSpec®
HDE Dimming 277V =T8 Electronic Dimming Ballast 120V = T8 Electronic Dimming Ballast 277V
Features
1. Housing
exposed fasteners. Concealed access holes in end plate for fhrough wiring.
2. Lamping:
3. Reflector:
aluminum reflecfor wifh 36° shielding crosswise.
4. Lens:
: Extruded aluminum. Die-cast end cap mechanically attached with no
Three T8 32 waff fluorescenf lamps, as specfied. Provided by others.
Accurate parabolic-shaped, die-formed semi-specular anodized
Exfruded 100% of acrylic clear debossed prismafic lens.
Electrical
Specify 120 volt or 277 volt. 3 conductor, 18 gauge wire. Color-coded quick connectors allow ease of connecfion for joiner modules. Eor special circuifing, consulf facfory. Rapid sfart, HPE, class "P" fhermally protecfed. PowerSpec HDE dimming ballast is available. Factory installed ballast disconnect allows the ballast fo be disconnecfed from and reconnecfed fo incoming power under load wifh ouf fuming fhe enfire circuif off.
Options and Accessories
Emergency bafferies available.
Ordering Instructions
Individual Fixtures:
1. Order number of EIXTURES (fixfure comes complefe wifh end caps, mounfing
Continuous Rows:
1. Defermine run lengfh.
2. Order fhe appropriafe number of EIXTURES for fhe complefe run. Eixfures can be
Labels
UL, cULand I.B.E.W.
Mountings
Cable Suspension
flat canopy finished enamel whife, 1/16" (0.16cm) diamefer sfainless sfeel aircraff cable adjusfable up fo 36" (91.44cm), adjusfable cable gripper.
Stem Mounting
(1.27cm) diameter rigid-mounted stem. White finish. Can be cuf fo lengfh on job. Self-aligning swivel provides adjusfabilify up fo 42° of slopes.
Surface & Wall Mounting
(not shown) -1-1/2" (3.81cm) and 4-1/2" (11.43cm) diameter
(not shown) - 4-1/2" (11.43cm) diameter flat canopy, 1/2"
(not shown) - consult factory for availabilify.
Finish
Powder coafed baked whife enamel. Cusfom colors available, consulf facfory.
hardware and power feeds).
bolted together and through wired to complete long runs.
Job Information
Job Name: Cat. No.:
Lamp(s): Notes:
1 Type:
Lightolier is a Philips group brand
631 Airport Road, Eall River, MA 02720 • (508) 679-8131 • Eax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • C1008
PHILIPS

LIGHTOLIIËR*

Lighting Systems CD7-6

Page 2 of 2

Performance and Quick Calculators
CANDLEPOWER CURVE
125
115
105
95" 90°
65"
55°
REPORT NO: LAMPS: LUMENS: EFFICIENCY:
Fixture Lengths & Mounting Locations
|-«-45-1/2” (115.57cm^ 6” (15.24cm)-
I
4-Foot Cable and Stem
LRL 496-1A
3L-32WT8
2900
49.3%
____
49” (124.46cm) —
I
Lowprofile Direct Lens 3-Light T8 Per 4-Foot Section
ZONE DEG. 180 0 0 0 0 0 175 0 0 0 0 0 165 0 0 0 0 0 155 0 0 0 0 0 145 0 0 0 0 0 135 0 0 0 0 0 125 0 0 0 0 0 115 0 0 0 0 0 105 0 0 0 0 0 95 0 0 0 0 0 90 0 0 0 0 0 85 40 50 40 50 30 75 90 150 80 130 100 65 130 270 220 200 120 55 450 560 510 420 320 45 1210 1100 940 840 810 35 1780 1700 1600 1490 1480 25 2050 2000 I960 1910 1900 15 2210 2190 2170 2140 2110
5 2260 2250 2260 2240 2240 0 2260 2260 2260 2260 2260
CANDLEPOWER
0 22 45 67 90
37” (93.98cm) ■
//////////////////////////
-49” (124.46cm)-
Wall
II
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
_J L_70_J L_
%WALL REFLECTANCE
503010 50 301050 30 10 0 59 59 59 57 57 57 55 55 55 1 53 52 50 52 51 50 50 49 48 2 49 46 44 48 46 44 46 45 43 3 45 42 40 44 42 39 43 41 39 4 41 38 36 41 38 35 40 37 35 5 38 35 32 38 34 32 37 34 32 6 35 32 29 35 31 29 34 31 29 7 32 29 26 32 29 26 31 28 26 8 30 26 24 29 26 24 29 26 24 9 27 24 22 27 24 22 27 24 22 10 24 21 18 24 21 18 24 20 18
20% FLOOR CAVITY REFLECTANCE
ZONAL LUMEN SUMMARY
Zone Lumens % Bare Lamo % Luminaire 0-90 4289 49.3 100.0
90-180 0 0.0 0.0
0-180 4289 49.3 100.0
SPACING RATIOS: PARALLEL = 1.2 / PERPENDICULAR= 1.7
ROOM SURFACE REFLECTANCES: 80% CEILING, 50% WALLS, 20% FLOOR
3200 LUMENS PER U\MP
/RCR = 1 ¡Rm, Width = lOxMtg, Ht above work plane) / RCR = 5 ¡Rm, Wd!h = 2xMtg, Ht above work plane)
/RCR = 10 ¡Rm, Width = Mtg, Ht, above work plane)
50
94-1/2” (240.03cm)
T T
------------------
98” (248.926cm) —
8-Foot Cable and Stem
Sample Run
---------
94-1/2” (240.03cm) -
8-Foot Fixture
49” (124.46cm)
Mounting Details
■ T
24”
(60.96cm)
i
I 3-1/4” (8.26cm)
- 9” (22.86cm)

Stem

fE

4-Foot Fixture 8-Foot Fixture

20' 5” (622.30cm)
94-1/2” (240.03cm)
T
7 :
9” (22.86cm)

Cable

24”
(60.96cm)
i
3-1/4” (8.26cm)
E«- 9” (22.86cm) -*-1T
50
40
20
10 20 30 40 50 60 70 80 90
3 4 5 6 7 8
4-1/2”
(15 43cm)
Surface
AREA PER FIXTURE IN SQUARE FEET
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
ABOVE DATA FOR 1LT-40 W 49" UNITS, FOR 2LT 49" UNITS FC X 17
3-5/8”(9.21cm)
3” (7.62cm)h-
Wall
Lightolier is a Philips group brand

Job Information Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.llghtoller.com © 2008 Philips Group • C1008
PHILIPS
Loading...