Calculite
®
CFL Lensed Wall Washer 8044
Page 1 of 2 7” Aperture (2) Quad Tube Wall Washer
2
14-5/8"
(372 mm)
Top View
11-3/8"
(289 mm)
12-1/2"
(318 mm)
5-1/4"
(134 mm)
Ceiling Cutout: 8” (203 mm) Dia.
6-3/4"
(171 mm)
(76 mm)
1" (25 mm) min.
2-1/8" (54 mm) max.
3"
4
5
7-1/8" (181 mm) Dia.
8-5/8" Self-Flanged
(209 mm)
7
1-1/8" (29 mm) max.
Ceiling Thickness
3
1
Reflector Trim Frame-In Kit
8044 CLW Clear Iridescence Free, White Flange S7218HU 7" aperture, 2 lamp 18W Quad Tube CFL (120/277V) 2-pin and 4-pin
8044 CLP Clear Iridescence Free, Polished Flange S7226HU 7" aperture, 2 lamp 26W Quad Tube CFL (120/277V) 2-pin and 4-pin
8044
S7218H or S7226H
CU3 Lightolier PowerSpec 3% Dimming (120/277V)
J1LD3 Lutron 5% Dimming (120V)
J2LD3 Lutron 5% Dimming (277V)
JUM7 Mark 7 Dimming (120/277V)
J1MX Mark 10 Dimming (120V)
J2MX Mark 10 Dimming (277V)
Other dimming product available, please consult factory
Features
1. Optics: Directional prismatic glass spread lens and Alzak® "kick" reflector
direct light smoothly across and down wall. Rotates for correct orientation.
Aperture cone with Iridescence Free finish.
2. Socket Cup: Die-cast aluminum cup effectively dissipates heat and positions
lamp holder. Snaps onto reflector neck to assure consistently correct optical
alignment without tools.
3. Mounting Frame: Die-cast aluminum for dry or plaster ceilings.
4. Retaining Springs: Precision-tooled steel friction springs secure reflector to
mounting frame for quick, tool-less installation.
5. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4" or
1 1/2" lathing channel, 1/2" EMT, or optional mounting bars.
6. Ballast/J-Box: Outboard mounted to reduce heat transfer and maintain
lamp efficacy and life. Service from below without tools.
7. Torsiontite Springs: Wire formed steel holds reflector/spread lens
assembly snug to housing.
Electrical
Note: For ballast electrical data and latest lamp/ballast compatibility refer to
“Ballast” specification sheet for complete electrical data.
UL listed for through branch circuit wiring with max of (8) No. 12 AWG, 90° C
supply conductors.
Add suffix. See options for other finishes. Standard Dimming Options:
Options and Accessories (continued)
Emergency Add Suf fix EM*
Chicago Plenum Add Suffix LC
Existing/Thk. Ceiling FA EC7*
Emergency Ltg. Kit FA EM3E* (4 pin)
FA EM4E* (4 pin)
FA EM2T* (2 pin)
Fuse (Slow Blow) Add Suffix F
*See Spec. Sheets: FAEC, FAEM
Mounting Bars & Accessories; see Specification Sheet MBA.
Sloped Ceiling Adapters; see Specification Sheet SCA.
Labels
UL listed for damp locations, I.B.E.W.
®
is a registered trademark of ALCOA.
Alzak
Job Information Type:
Job Name:
Cat. No.:
Options and Accessories
Comfort Clear Finishes1 Other Finishes
Clear CCL White WH
Diffuse CCD
Champagne Bronze CCZ
Pewter CPW
1
Specif y desired flange
W White, P Polished
Blank - Molded Ring
Lamp(s):
Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • F0711
6
Lightolier is a Philips group brand

Calculite
®
CFL Lensed Wall Washer 8044
Page 2 of 2 7” Aperture (2) Quad Tube Wall Washer
Lighting Data
EXAMPLE: With multiple clear reflector units located
2’ from wall and 3’ on center, the illumination on the
3’
2’
3’
35 f.c.
35 f.c.
Footcandles On Wall From Multiple Units - 2 Lt. - 26w Quad TubeFootcandles On Wall From Multiple Units - 2 Lt. - 26w Quad Tube
Units 2 Feet From Wall
2’ 3’
wall 3’ down from the ceiling is 35 f.c. beneath and 35
f.c. between fixtures.
Distance From Ceiling, Ft.
Distance From Ceiling, Ft.
1
40 36 40
2
63 64 63
3
52 53 52
4
38 39 38
5
29 29 29
6
23 23 23
7
18 18 18
8
16 16 16
9
14 14 14
1
12 11 12
2
26 26 26
3
30 30 30
4
26 27 26
5
21 22 21
6
17 17 17
7
14 14 14
8
12 12 12
9
11 11 11
32 19 32
46 38 46
35 35 35
26 26 26
19 19 19
15 15 15
12 12 12
10 10 10
999
Units 3 Feet From Wall
3’ 4’
10 810
22 17 22
23 21 23
20 20 20
17 17 17
14 14 14
12 12 12
10 10 10
999
Footcandles values are averaged and rounded off and are based on a minimum of five units. For fixture-to-wall distances, other than
those shown, use maximum of 1 to 1 spacing (distance between fixtures not more than distance to wall) for best results.
Lightolier is a Philips group brand
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • F0711