Philips Semiconductors Objective specification
Damper diode BY559-1500U
fast, high-voltage
FEATURES SYMBOL QUICK REFERENCE DATA
• Low forward volt drop VR = 1500 V
• Low forward recovery voltage
• Fast switching VF ≤ 1.4 V
• Soft recovery characteristic
• High thermal cycling performance Vfr ≤ 10 V
• Low thermal resistance
GENERAL DESCRIPTION PINNING SOD59 (TO220AC)
k a
12
I
I
trr ≤ 120 ns
= 10 A
F(peak)
≤ 150 A
FSM
A double diffused rectifier diode in PIN DESCRIPTION
a plastic envelope, featuring fast
tab
forward and reverse recovery and 1 cathode
low forward voltage. The device is
intendedfor use as a damper diode 2 anode
in horizontal deflection circuits of
large screen monitors and tab cathode
workstations .
1
The BY559 series is suppliedin the
2
conventional leaded SOD59
(TO220AC) package.
LIMITING VALUES
Limiting values in accordance with the Absolute Maximum System (IEC 134).
SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT
V
RRM
V
RWM
I
F(PEAK)
I
FRM
I
FSM
Peak repetitive reverse voltage - 1500 V
Crest working reverse voltage - 1300 V
Peak working forward current f = 130 kHz; - 10 A
Peak repetitive forward current t = 100 µs - 150 A
Peak non-repetitive forward t = 10 ms - 160 A
current sinusoidal; Tj = 150 ˚C prior to
surge; with reapplied V
T
stg
T
j
Storage temperature -40 150 ˚C
Operating junction temperature - 150 ˚C
RWM(max)
THERMAL RESISTANCES
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
R
R
th j-mb
th j-a
Thermal resistance junction to - - 1.0 K/W
mounting base
Thermal resistance junction to in free air - 60 - K/W
ambient
September 1998 1 Rev 1.100
Philips Semiconductors Objective specification
Damper diode BY559-1500U
fast, high-voltage
STATIC CHARACTERISTICS
Tj = 25 ˚C unless otherwise stated
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
V
F
I
R
DYNAMIC CHARACTERISTICS
Tj = 25 ˚C unless otherwise stated
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
V
fr
t
fr
t
rr
Q
s
Forward voltage IF = 6.5 A - 1.5 1.8 V
IF = 6.5 A; Tj = 125 ˚C - 1.2 1.4 V
Reverse current VR = V
VR = V
RWMmax
; Tj = 125 ˚C - - 2.0 mA
RWMmax
- - 0.5 mA
Forward recovery voltage IF = 6.5 ; dIF/dt = 50 A/µs-610V
Forward recovery time IF = 6.5 A; dIF/dt = 50 A/µs; VF = 5 V - 130 180 ns
Reverse recovery time IF = 1 A; -dIF/dt = 50 A/µs; VR ≥ 30 V - 90 120 ns
Reverse recovery charge IF = 2 A; -dIF/dt = 20 A/µs; VR ≥ 30 V - 0.2 0.25 µC
September 1998 2 Rev 1.100