Philips BUK204-50Y Datasheet

Philips Semiconductors Product specification
TOPFET high side switch BUK204-50Y SMD version of BUK200-50Y
DESCRIPTION QUICK REFERENCE DATA
Monolithic temperature and SYMBOL PARAMETER MIN. UNIT overload protected power switch based on MOSFET technology in a I 5 pin plastic surface mount
L
envelope, configured as a single high side switch. SYMBOL PARAMETER MAX. UNIT
APPLICATIONS V
General controller for driving T lamps, motors, solenoids, heaters. R
BG
I
L
j
ON
FEATURES FUNCTIONAL BLOCK DIAGRAM
Vertical power DMOS switch Low on-state resistance 5 V logic compatible input Overtemperature protection ­self resets with hysteresis Overload protection against short circuit load with output current limiting; latched - reset by input High supply voltage load protection Supply undervoltage lock out Status indication for overload protection activated Diagnostic status indication of open circuit load Very low quiescent current Voltage clamping for turn off of inductive loads ESD protection on all pins Reverse battery and overvoltage protection Fig.1. Elements of the TOPFET HSS with internal ground resistor.
STATUS
INPUT
GROUND
CONTROL &
PROTECTION
CIRCUITS
RG
BATT
POWER MOSFET
LOAD
PINNING - SOT426 PIN CONFIGURATION SYMBOL
PIN DESCRIPTION
1 Ground 2 Input 3 (connected to mb) 4 Status 5 Load
3
12 45
mb Battery
July 1996 1 Rev 1.000
mb
B
I
TOPFET
HSS
S
G
Fig. 2. Fig. 3.
L
Philips Semiconductors Product specification
TOPFET high side switch BUK204-50Y SMD version of BUK200-50Y
LIMITING VALUES
Limiting values in accordance with the Absolute Maximum System (IEC 134)
SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT
Battery voltages
V
-V
-V
BG
BG
BG
Continuous off-state supply voltage - 0 50 V
Reverse battery voltages
1
External resistors: Repetitive peak supply voltage RI = RS 4.7 k, δ 0.1 - 32 V Continuous reverse supply voltage RI = RS 4.7 k -16V
I
L
P
D
T
stg
T
j
T
sold
Continuous load current T Total power dissipation T
115 ˚C - 10 A
mb ≤
25 ˚C - 62.5 W
mb ≤
Storage temperature - -55 175 ˚C Continuous junction temperature
2
- - 150 ˚C
Lead temperature during soldering - 250 ˚C
Input and status
I
I
I
S
I
I
I
S
Continuous input current - -5 5 mA Continuous status current - -5 5 mA
Repetitive peak input current δ 0.1 -20 20 mA Repetitive peak status current δ 0.1 -20 20 mA
Inductive load clamping
E
BL
Non-repetitive clamping energy Tmb = 150 ˚C prior to turn-off - 1.2 J
ESD LIMITING VALUE
SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT
V
C
Electrostatic discharge capacitor Human body model; - 2 kV voltage C = 250 pF; R = 1.5 k
THERMAL CHARACTERISTIC
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
Thermal resistance
R
th j-mb
1 Reverse battery voltage is allowed only with external input and status resistors to limit the currents to a safe value. 2 For normal continuous operation. A higher Tj is allowed as an overload condition but at the threshold T
3 Of the output Power MOS transistor.
Junction to mounting base - - 1.5 2 K/W
to protect the switch.
July 1996 2 Rev 1.000
3
the over temperature trip operates
j(TO)
Philips Semiconductors Product specification
TOPFET high side switch BUK204-50Y SMD version of BUK200-50Y
STATIC CHARACTERISTICS
Tmb = 25 ˚C unless otherwise stated
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
Clamping voltages
V V
-V
V
I I I I
BG
BL
LG
BG
L
B
G
L
Battery to ground IG = 1 mA 50 55 65 V Battery to load IL = IG = 1 mA 50 55 65 V Negative load to ground IL = 1 mA 12 17 21 V
Supply voltage battery to ground Operating range
1
-5-40V
Currents VBG = 13 V Nominal load current Quiescent current Operating current Off-state load current
2
3
4
5
VBL = 0.5 V; Tmb = 85 ˚C 3.5 - - A VIG = 0 V; VLG = 0 V - 0.1 2 µA VIG = 5 V; IL = 0 A 1.5 2.2 4 mA VBL = 13 V; VIG = 0 V - 0.1 1 µA
Resistances
R
ON
R
ON
R
G
On-state resistance On-state resistance VBG = 5 V; IL = 1 A; tp = 300 µs - 116 150 m Internal ground resistance IG = 10 mA - 150 -
6
VBG = 13 V; IL = 5 A; tp = 300 µs - 77 100 m
INPUT CHARACTERISTICS
Tmb = 25 ˚C; VBG = 13 V
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
I
I
V
IG
V
IG(ON)
V
IG(OFF)
Input current VIG = 5 V 35 60 100 µA Input clamping voltage II = 200 µA 6 7.5 8.5 V Input turn-on threshold voltage - 2.1 2.7 V Input turn-off threshold voltage 1.5 2 - V
1 On-state resistance is increased if the supply voltage is less than 9 V. Refer to figure 8. 2 Defined as in ISO 10483-1. 3 This is the continuous current drawn from the battery when the input is low and includes leakage current to the load. 4 This is the continuous current drawn from the battery with no load connected, but with the input high. 5 The measured current is in the load pin only. 6 The supply and input voltage for the RON tests are continuous. The specified pulse duration tp refers only to the applied load current.
July 1996 3 Rev 1.000
Philips Semiconductors Product specification
TOPFET high side switch BUK204-50Y SMD version of BUK200-50Y
PROTECTION FUNCTIONS AND STATUS INDICATIONS
Truth table for normal, open-circuit load and overload conditions and abnormal supply voltages.
FUNCTIONS TRUTH TABLE THRESHOLD
SYMBOL CONDITION INPUT STATUS OUTPUT MIN. TYP. MAX. UNIT
Normal on-state 1 1 1 Normal off-state 0 1 0
I
L(OC)
T
j(TO)
V
BL(TO)
V
BG(TO)
V
BG(LP)
Open circuit load Open circuit load 0 1 0 Over temperature Over temperature Short circuit load Short circuit load 0 1 0 Low supply voltage High supply voltage
For input ‘0’ equals low, ‘1’ equals high, ‘X’ equals don’t care. For status ‘0’ equals low, ‘1’ equals open or high. For output switch ‘0’ equals off, ‘1’ equals on.
1
2
3
4
5
6
1 0 1 50 200 350 mA
1 0 0 150 175 - ˚C 00 0 1 0 0 8.5 10.3 12 V
X1 0345V X1 0404550V
STATUS CHARACTERISTICS
Tmb = 25 ˚C. The status output is an open drain transistor, and requires an external pull-up circuit to indicate a logic high.
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
V
SG
V
SG
I
S
I
S
R
S
1 In the on-state, the switch detects whether the load current is less than the quoted open load threshold current. This is for status indication
2 After cooling below the reset temperature the switch will resume normal operation. The reset temperature is lower than the trip temperature by
3 If the overtemperature protection has operated, status remains low to indicate the overtemperature condition even if the input is taken low,
4 After short circuit protection has operated, the input voltage must be toggled low for the switch to resume normal operation. 5 Undervoltage sensor causes the device to switch off. Typical hysteresis equals 0.7 V. 6 Overvoltage sensor causes the device to switch off to protect the load. Typical hysteresis equals 1.3 V. 7 In a fault condition with the pull-up resistor short circuited while the status transistor is conducting. 8 The pull-up resistor also protects the status pin during reverse battery conditions.
Status clamping voltage IS = 100 µA; VIG = 0 V 6 7 8 V Status low voltage IS = 50 µA; VBG = 13 V; VIG = 5 V - 0.7 0.8 V Status leakage current VSG = 5 V - 0.1 1 µA Status saturation current
7
VSS = 5 V; RS = 0 ; VBG = 13 V - 5 - mA
Application information
External pull-up resistor
only. Typical hysteresis equals 80 mA. The thresholds are specified for supply voltage within the normal working range.
typically 10 ˚C.
providing the device has not cooled below the reset temperature.
8
VSS = 5 V - 100 - k
July 1996 4 Rev 1.000
Loading...
+ 9 hidden pages