Philips bta208s DATASHEETS

Philips Semiconductors Product specification
Three quadrant triacs BTA208S series B high commutation

GENERAL DESCRIPTION QUICK REFERENCE DATA

Glass passivated high commutation SYMBOL PARAMETER MAX. MAX. MAX. UNIT triacs in a plastic envelope, suitable forsurfacemounting,intendedforuse BTA208S (or BTA208M)- 500B 600B 800B in circuits where high static and V
DRM
dynamic dV/dt and high dI/dt can voltages occur. These devices will commutate I the full rated rms current at the I
T(RMS) TSM
maximumratedjunction temperature, current without the aid of a snubber.

PINNING - SOT428 PIN CONFIGURATION SYMBOL

Repetitive peak off-state 500 600 800 V RMS on-state current 8 8 8 A
Non-repetitive peak on-state 65 65 65 A
BTA208M series B
PIN Standard Alternative
tab
NUMBER S M
1 MT1 gate
T1T2
2 MT2 MT2 3 gate MT1
tab MT2 MT2
2
1
3
G

LIMITING VALUES

Limiting values in accordance with the Absolute Maximum System (IEC 134).

SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT

-500 -600 -800
V
DRM
I
T(RMS)
Repetitive peak off-state - 500 voltages
RMS on-state current full sine wave; - 8 A
1
Tmb 102 ˚C
I
TSM
Non-repetitive peak full sine wave; on-state current Tj = 25 ˚C prior to
surge t = 20 ms - 65 A
I2tI
2
t for fusing t = 10 ms - 21 A2s
t = 16.7 ms - 71 A
dIT/dt Repetitive rate of rise of ITM = 12 A; IG = 0.2 A; 100 A/µs
on-state current after dIG/dt = 0.2 A/µs
triggering I V P P
T T
GM
GM GM G(AV)
stg j
Peak gate current - 2 A
Peak gate voltage - 5 V
Peak gate power - 5 W
Average gate power over any 20 ms - 0.5 W
period Storage temperature -40 150 ˚C Operating junction - 125 ˚C temperature
600
1
800 V
1 Although not recommended, off-state voltages up to 800V may be applied without damage, but the triac may switch to the on-state. The rate of rise of current should not exceed 6 A/µs.
September 1997 1 Rev 1.200
Philips Semiconductors Product specification
Three quadrant triacs BTA208S series B high commutation

THERMAL RESISTANCES

SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
R
th j-mb
R
th j-a

STATIC CHARACTERISTICS

Tj = 25 ˚C unless otherwise stated
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
I
GT
I
L
I
H
V
T
V
GT
I
D
Thermal resistance full cycle - - 2.0 K/W junction to mounting base half cycle - - 2.4 K/W Thermal resistance pcb (FR4) mounted; footprint as in Fig.14 - 75 - K/W junction to ambient
Gate trigger current
2
VD = 12 V; IT = 0.1 A
T2+ G+ 2 18 50 mA T2+ G- 2 21 50 mA T2- G- 2 34 50 mA
Latching current VD = 12 V; IGT = 0.1 A
T2+ G+ - 31 60 mA T2+ G- - 34 90 mA
T2- G- - 30 60 mA Holding current VD = 12 V; IGT = 0.1 A - 31 60 mA On-state voltage IT = 10 A - 1.3 1.65 V Gate trigger voltage VD = 12 V; IT = 0.1 A - 0.7 1.5 V
VD = 400 V; IT = 0.1 A; Tj = 125 ˚C 0.25 0.4 - V
Off-state leakage current VD = V
; Tj = 125 ˚C - 0.1 0.5 mA
DRM(max)
BTA208M series B

DYNAMIC CHARACTERISTICS

Tj = 25 ˚C unless otherwise stated
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
dVD/dt Critical rate of rise of VDM = 67% V
off-state voltage exponential waveform; gate open circuit
dI
/dt Critical rate of change of VDM = 400 V; Tj = 125 ˚C; I
com
t
gt
commutating current without snubber; gate open circuit Gate controlled turn-on ITM = 12 A; VD = V time dIG/dt = 5 A/µs
; Tj = 125 ˚C; 1000 4000 - V/µs
DRM(max)
= 8 A; - 14 - A/ms
T(RMS)
; IG = 0.1 A; - 2 - µs
DRM(max)
2 Device does not trigger in the T2-, G+ quadrant.
September 1997 2 Rev 1.200
Loading...