Philips BGY1085A Datasheet

DISCRETE SEMICONDUCTORS
DATA SH EET
BGY1085A
CATV amplifier module
Product specification Supersedes data of 1995 Sep 11 File under Discrete Semiconductors, SC16
1997 Apr 15
Philips Semiconductors Product specification
CATV amplifier module BGY1085A
FEATURES
Excellent linearity
Extremely low noise
Silicon nitride passivation
Rugged construction
Gold metallization ensures
excellent reliability.
DESCRIPTION
PINNING - SOT115J
PIN DESCRIPTION
1 input 2 common 3 common 5+V
B
7 common 8 common 9 output
page
2
351
Side view
Fig.1 Simplified outline.
789
Hybrid high amplifier module for CATV systems operating over a frequency range of 40 to 1000 MHz at a supply voltage of +24 V (DC).
QUICK REFERENCE DATA
SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT
G
p
power gain f = 50 MHz 18 19 dB
f = 1000 MHz 18.5 dB
I
tot
total current consumption (DC) VB=24V 240 mA
MSA319
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 134).
SYMBOL PARAMETER MIN. MAX. UNIT
V
i
T
stg
T
mb
RF input voltage 65 dBmV storage temperature 40 +100 °C operating mounting base temperature 20 +100 °C
Philips Semiconductors Product specification
CATV amplifier module BGY1085A
CHARACTERISTICS Table 1 Bandwidth 40 to 1000 MHz; T
=30°C; ZS=ZL=75
case
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
G
p
power gain f = 50 MHz 18 19 dB
f = 1000 MHz 18.5 −−dB SL slope cable equivalent f = 40 to 1000 MHz 0 2dB FL flatness of frequency response f = 40 to 1000 MHz −−±0.3 dB S
11
input return losses f = 40 to 80 MHz 20 −−dB
f = 80 to 160 MHz 18.5 −−dB
f = 160 to 320 MHz 17 −−dB
f = 320 to 640 MHz 15.5 −−dB
f = 640 to 1000 MHz 14 −−dB S
22
output return losses f = 40 to 80 MHz 20 −−dB
f = 80 to 160 MHz 18.5 −−dB
f = 160 to 320 MHz 17 −−dB
f = 320 to 640 MHz 15.5 −−dB
f = 640 to 1000 MHz 14 −−dB CTB composite triple beat 85 channels flat;
V
= 44 dBmV;
o
−−−58 dB
measured at 595.25 MHz
110 channels flat;
V
= 44 dBmV;
o
−−−53 dB
measured at 745.25 MHz
150 channels flat;
V
= 40 dBmV;
o
−−53 dB
measured at 985.25 MHz X
mod
cross modulation 85 channels flat;
−−−58 dB Vo= 44 dBmV; measured at 55.25 MHz
110 channels flat; V
= 44 dBmV;
o
−−−54 dB
measured at 55.25 MHz 150 channels flat;
V
= 40 dBmV;
o
−−54 dB
measured at 55.25 MHz
CSO composite second order
distortion
85 channels flat;
= 44 dBmV;
V
o
−−−60 dB
measured at 596.5 MHz 110 channels flat;
V
= 44 dBmV;
o
−−−56 dB
measured at 746.5 MHz 150 channels flat;
= 40 dBmV;
V
o
−−56 dB
measured at 986.5 MHz