Product data
Cap-Base G13 [ Medium Bi-Pin Fluorescent]
Nominal Lifetime (Nom) 50000 h
Switching Cycle 200000X
B50L70 50000 h
Light Technical
Color Code 840 [ CCT of 4000K]
Luminous Flux (Nom) 3700 lm
Luminous Flux (Rated) (Nom) 3700 lm
Correlated Color Temperature (Nom) 4000 K
Color Consistency <6
Color Rendering Index (Nom) 83
LLMF At End Of Nominal Lifetime (Nom) 70 %
Operating and Electrical
Input Frequency 50 to 60 Hz
Power (Rated) (Nom) 24 W
Lamp Current (Max) 112 mA
Lamp Current (Min) 103 mA
Starting Time (Nom) 0.5 s
Warm Up Time To 60% Light (Nom) 0.5 s
Power Factor (Nom) 0.9
Voltage (Nom) 220-240 V
Temperature
T-Ambient (Max) 45 °C
T-Ambient (Min) -20 °C
T-Storage (Max) 65 °C
T-Storage (Min) -40 °C
T-Case Maximum (Nom) 60 °C
Controls and Dimming
Dimmable No
Mechanical and Housing
Product Length 1500 mm
Datasheet, 2017, March 3 data subject to change
A1
A2
A3
D2
D1
2016-12-27
1 x TLED 24W 4000K 160D 9290012982
1 x 3700 lm
Light output ratio 1.00
Service upward 0.15 Service downward 0.85
CIE flux code 40 69 88 85 100
UGRcen (4Hx8H, 0.25H) 26
Polar intensity diagram
(cd/1000lm)
0-180o90-270
o
0
o
180
o
30oo30
60oo60
90oo90
120oo120
50
100
150
200
250
300
γ
Utilisation factor table
Ceiling mounted
Room Index k
Reflectances (%) for ceiling, walls and working plane (CIE)
0.60
0.80
1.00
1.25
1.50
2.00
2.50
3.00
4.00
5.00
0.80
0.50
0.30
0.43
0.53
0.61
0.69
0.75
0.85
0.91
0.96
1.02
1.06
0.80
0.50
0.10
0.41
0.50
0.57
0.63
0.68
0.76
0.81
0.84
0.89
0.91
0.70
0.50
0.30
0.41
0.51
0.59
0.66
0.72
0.81
0.87
0.92
0.97
1.01
0.70
0.50
0.20
0.40
0.49
0.57
0.64
0.69
0.77
0.82
0.86
0.91
0.95
0.70
0.50
0.10
0.40
0.48
0.55
0.61
0.66
0.73
0.78
0.82
0.86
0.89
0.70
0.30
0.10
0.32
0.40
0.47
0.54
0.59
0.67
0.73
0.77
0.82
0.85
0.50
0.30
0.10
0.31
0.38
0.45
0.51
0.56
0.64
0.69
0.73
0.77
0.81
0.50
0.10
0.10
0.26
0.33
0.40
0.46
0.51
0.59
0.65
0.69
0.74
0.78
0.30
0.30
0.10
0.29
0.36
0.43
0.49
0.53
0.60
0.65
0.69
0.73
0.76
0.30
0.10
0.10
0.25
0.32
0.38
0.44
0.49
0.57
0.62
0.66
0.71
0.74
0.00
0.00
0.00
0.22
0.28
0.34
0.40
0.44
0.51
0.56
0.60
0.65
0.68
Quantity estimation diagram
nr. of luminaires
0
6
12
18
24
)2(m10 30 50 70 90
300 lx
500 lx
750 lx
h
room
: 2.8 m Reflectances: 0.70, 0.50, 0.20 Maintenance factor: 1.0 Ceiling mounted
UGR diagram
4.0
4.0
8.0
8.0
12.0
12.0
16.0
16.0
m
m
X
Y
h
room
: 2.8 m
Refl: 0.70 0.50 0.20
Ceiling mounted
: viewed endwise
: viewed crosswise
Y: Parallel to viewing dir.
25
25
28
25
Luminance Table
)2(cd/m
0.0 15.0 30.0 45.0 60.0 75.0 90.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
Plane Cone
12445
11714
11013
10329
9686
9099
8593
8155
7767
7443
12099
11315
10568
9850
9175
8565
8043
7586
7179
6841
12157
11325
10533
9778
9070
8434
7898
7427
7008
6671
12644
11769
10933
10142
9398
8737
8194
7717
7302
6994
13675
12727
11782
10848
9924
9046
8243
7477
6819
6538
15439
14467
13441
12367
11233
10065
8863
7583
6407
6181
18352
17534
16602
15545
14322
12906
11146
8692
5201
2551
General Uniform Lighting
CalcuLuX Photometrics 4.5 Philips Lighting B.V. Page: 1/1
200
400300
500
600
0
40
80
20
60
700 800
100
[nm]
Intensity (%)
MASTER LEDtube EM/Mains T8
Approval and Application
Energy Saving Product Yes
Energy Efficiency Label (EEL) A++
Approval Marks TUV CE marking RoHS compliance KEMA Keur
certificate
Energy Consumption kWh/1000 h 24 kWh
Order product name MAS LEDtube 1500mm UO 24W 840 T8
EAN/UPC - Product 8718696687444
Order code 929001298202
Numerator - Quantity Per Pack 1
Numerator - Packs per outer box 10
Material Nr. (12NC) 929001298202
Net Weight (Piece) 0.450 kg
Product Data
Full product code 871869668744400
Warnings and Safety
• NOTES: The overall energy efficiency and light distribution of any installation that uses these lamps are determined by the design of the
installation.
Dimensional drawing
Product D1 D2 A1 A2 A3
MAS LEDtube 1500mm UO 24W
840 T8
25.78 mm 28 mm 1498.7 mm 1505.8 mm 1512.9 mm
TLED 4ft 24W-58W 3700lm 160D 4000K G13ND
Photometric data
2Datasheet, 2017, March 3 data subject to change
Loading...
+ 1 hidden pages