INTEGRATED CIRCUITS
74LV4053
Triple 2-channel analog
multiplexer/demultiplexer
Product specification
Supersedes data of 1997 Jul 15
IC24 Data Handbook
1998 Jun 23
Philips Semiconductors Product specification
74L V4053Triple 2-channel analog multiplexer/demultiplexer
FEA TURES
•Optimized for low voltage applications: 1.0 to 6.0 V
•Accepts TTL input levels between V
= 2.7 V and V
CC
CC
= 3.6 V
•Low typ “ON” resistance:
100 at V
150 at V
240 at V
– VEE = 4.5 V
cc
– VEE = 3.0 V
cc
– VEE = 2.0 V
cc
•Logic level translation: to enable 3 V logic to communicate with ± 3
V analog signals
•Typical “break before make” built in
•Output capability: non-standard
•I
category: MSI
CC
QUICK REFERENCE DATA
GND = 0 V; T
= 25°C; tr =t
amb
SYMBOL
Turn “ON” time
t
PZH/tPZL
E to V
Sn to V
OS
Turn “OFF” time
t
PHZ/tPLZ
C
I
C
PD
C
S
E to V
OS
Sn to V
Input capacitance 3.5
Power dissipation capacitance per switch See Notes 1 and 2 36
Maximum switch capacitance
independent (Y) common (Z)
NOTES:
1. C
is used to determine the dynamic power dissipation (PD in µW)
PD
P
= CPD × V
D
= input frequency in MHz; CL = output load capacity in pF;
f
i
f
= output frequency in MHz; CS = maximum switch capacitance in pF;
o
= supply voltage in V;
V
CC
((C
+CS) × V
L
CC
2
CC
2. The condition is V
≤ 2.5 ns
f
PARAMETER CONDITIONS TYPICAL UNIT
CL = 15 pF
R
= 1K
L
OS
OS
× fi ((C
2
× fo) = sum of the outputs.
= GND to VCC.
I
L +
CS) × V
2
× fo) where:
CC
VCC = 3.3 V
DESCRIPTION
The 74LV4053 is a low-voltage CMOS device and is pin and
function compatible with the 74HC/HCT4053.
The 74LV4053 is a triple 2-channel analog multiplexer/demultiplexer with
a common enable input (E
independent inputs/outputs (nY
and three digital select inputs (S
LOW, one of the two switches is selected (low impedance
With E
ON-state) by S
impedance OFF-states, independent of S
and GND are the supply voltage pins for the digital control inputs
V
CC
(S
, to S3, and E). The VCC to GND ranges are 1.0 to 6.0 V. The
1
analog inputs/outputs (nY
to S3 With E HIGH, all switches are in the high
1
as a pos i t iv e l i m i t a n d VEE as a negative limit. VCC - VEE may not
exceed 6.0 V. For operation as a digital multiplexer/demultiplexer, V
is connected to GND (typically ground).
). Each multiplexer/demultiplexer has two
to nY1), a common input/output (nZ)
0
to S3).
1
and S3.
1
, to nY1, and nZ ) c a n s w i n g b e t w e e n V
0
16
20
17
16
5
8
CC
EE
p
ORDERING INFORMATION
PACKAGES TEMPERATURE RANGE OUTSIDE NORTH AMERICA NORTH AMERICA PKG. DWG. #
16-Pin Plastic DIL –40°C to +125°C 74LV4053 N 74LV4053 N SOT38-1
16-Pin Plastic SO –40°C to +125°C 74LV4053 D 74LV4053 D SOT109-1
16-Pin Plastic SSOP Type II –40°C to +125°C 74LV4053 DB 74LV4053 DB SOT338-1
16-Pin Plastic TSSOP Type I –40°C to +125°C 74LV4053 PW 74LV4053PW DH SOT403-1
PIN CONFIGURATION
1998 Jun 23
2Y
2Y
3Y
3Y
V
GND
PIN DESCRIPTION
1
1
2
0
3
1
4
3Z
5
0
6
E
7
EE
8
16
15
14
13
12
11
10
9
SV01687
V
CC
2Z
1Z
1Y
1
1Y
0
S
1
S
2
S
3
PIN NUMBER SYMBOL FUNCTION
2, 1 2Y0, 2Y
5, 3 3Y0, 3Y
Independent inputs/outputs
1
Independent inputs/outputs
1
6 E Enable input (active LOW)
7 V
EE
Negative supply voltage
8 GND Ground (0 V)
11, 10, 9 S1 to S
12, 13 1Y0, 1Y
Select inputs
3
Independent inputs/outputs
1
14, 15, 4 1Z to 3Z Common inputs/outputs
16 V
CC
Positive supply voltage
2
853-2000 19618
Philips Semiconductors Product specification
74LV4053Triple 2-channel analog multiplexer/demultiplexer
LOGIC SYMBOL
11
S
1Y
1
10
S
1Y
2
9
S
3
2Y
2Y
3Y
3Y
6E
2Z1Z3Z
15144
LOGIC SYMBOL (IEEE/IEC)
6
G3
14
11
15
10
4
9
MDX
#
3X1
3X2
#
#
FUNCTION TABLE
0
1
0
1
0
1
1
2
12
13
2
1
5
3
SV01659
13
12
1
2
3
5
SV01693
FUNCTIONAL DIAGRAM
6
16
V
E
CC
11
S
1
10
S
2
9
S
LOGIC
3
LEVEL
CONVERSION
DECODER
14
1Z
1Y
1
13
1Y
12
0
15
2Z
2Y
1
1
2Y
2
0
4
3Z
3Y
1
3
3Y
5
0
INPUTS
E Sn
L L nY0 – nZ
L H nY1 – nZ
H X None
NOTES:
H = HIGH voltage level
L = LOW voltage level
X = don’t care
SCHEMATIC DIAGRAM (ONE SWITCH)
from logic
CHANNEL
ON
Y
V
CC
Z
SV01695
V
EE
7
SV01694
V
EE
V
EE
GND
8
V
CC
V
CC
V
CC
V
EE
1998 Jun 23
3
Philips Semiconductors Product specification
74LV4053Triple 2-channel analog multiplexer/demultiplexer
ABSOLUTE MAXIMUM RATINGS
1, 2
In accordance with the Absolute Maximum Rating System (IEC 134).
Voltages are referenced to GND (ground = 0 V).
SYMBOL
V
CC
I
IK
I
SK
I
S
T
stg
P
TOT
DC supply voltage –0.5 to +7.0 V
DC input diode current VI < –0.5 or VI > VCC + 0.5 V 20 mA
DC switch diode current VO < –0.5 or VO > VCC + 0.5 V 20 mA
DC switch current –0.5 V < VS < VCC + 0.5 V 25 mA
Storage temperature range –65 to +150 °C
Power dissipation per package
– plastic DIL
– plastic mini-pack (SO)
– plastic shrink mini-pack (SSOP and TSSOP)
PARAMETER CONDITIONS RATING UNIT
for temperature range: –40 to +125°C
above +70°C derate linearly with 12 mW/K
above +70°C derate linearly with 8 mW/K
above +60°C derate linearly with 5.5 mW/K
750
500
400
mW
NOTES:
1. Stresses beyond those listed may cause permanent damage to the device. These are stress ratings only and functional operation of the
device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to
absolute-maximum-rated conditions for extended periods may affect device reliability .
2. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
RECOMMENDED OPERATING CONDITIONS
SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNIT
V
V
V
T
amb
tr, t
NOTE:
1. The LV is guaranteed to function down to V
DC supply voltage See Note 1 and Figure 5 1.0 3.3 6.0 V
CC
Input voltage 0 – V
I
Output voltage 0 – V
O
Operating ambient temperature range in free air
Input rise and fall times
f
= 1.0V (input levels GND or VCC); DC characteristics are guaranteed from VCC = 1.2V to VCC = 6.0V .
CC
See DC and AC
characteristics
VCC = 1.0 V to 2.0 V
VCC = 2.0 V to 2.7 V
VCC = 2.7 V to 6.0 V
–40
–40
–
–
–
–
–
–
CC
CC
+85
+125
500
200
100
V
V
°C
ns/V
1998 Jun 23
4
Philips Semiconductors Product specification
74LV4053Triple 2-channel analog multiplexer/demultiplexer
DC ELECTRICAL CHARACTERISTICS
Over recommended operating conditions, voltages are referenced to GND (ground = 0 V)
LIMITS
SYMBOL P ARAMETER TEST CONDITIONS
VCC = 1.2 V 0.9 0.9
VCC = 2.0 V 1.4 1.4
V
IH
evel Inpu
VCC = 2.7 to 3.6 V 2.0 2.0
VCC = 4.5 V 3.15 3.15
VCC = 6.0 V 4.20 4.20
VCC = 1.2 V 0.3 0.3
VCC = 2.0 V 0.6 0.6
V
IL
evel Inpu
VCC = 2.7 to 3.6 V 0.8 0.8
VCC = 4.5 V 1.35 1.35
VCC = 6.0 V 1.80 1.80
I
S
S
CC
Input leakage
current
Analog switch
per channel
Analog switch
ON-state current
Quiescent supply
current
VCC = 3.6
VCC = 6.0
VCC = 3.6
VCC = 6.0
VCC = 3.6
VCC = 6.0
VCC = 3.6 V
VCC = 6.0 V
=
I
CC
VI = VIH or V
=
(See Figure 2)
VI = VIH or V
=
(See Figure 3)
VI = VCC or GND
VIS = GND or VCC;
V
= VCC or GND
OS
Additional
CC
quiescent supply
current per input
VCC = 2.7 to 3.6 V VI = VCC – 0.6 V 500 850 µA
∆I
IS = 100 mA;
V
VCC = 1.2 V
R
ON
-
(peak)
VCC = 2.0 V 180 365 435
VCC = 2.7 V
VCC = 3.0 to 3.6 V
VCC = 4.5 V
VCC to GND;
IS =
VI = VIH or V
I
= 1000
V
VCC to GND;
IS =
=
I
IH
VCC = 6.0 V 70 140 165
IS = 100 mA;
V
VCC = 1.2 V
R
ON
-
(rail)
VCC = 2.0 V 120 280 325
VCC = 2.7 V
VCC = 3.0 to 3.6 V
VCC = 4.5 V
GND;
IS =
VI = VIH or V
I
= 1000
V
GND;
IS =
=
I
IH
VCC = 6.0 V 45 105 120
VI = VIH or VIL;
= 100 mA;
VCC = 1.2 V
R
ON
(rail)
VCC = 2.0 V 170 340 400
VCC = 2.7 V
VCC = 3.0 to 3.6 V
VCC = 4.5 V
I
S
V
V
IS =
V
= V
IS = 1000 mA;
IS =
VCC = 6.0 V 65 125 150
CC
CC
or
or
CC
or V
or
CC
or
IL
-
IL
-
IL
A;
IL
IL
A;
IL
;
-40°C to +85°C -40°C to +125°C
MIN TYP
1
MAX MIN MAX
1.0 1.0
2.0 2.0
1.0 1.0
2.0 2.0
1.0 1.0
2.0 2.0
20.0 40
40.0 80
115 225 270
100 200 245
75 150 180
250
75 170 195
70 155 180
50 120 135
350
105 210 250
95 190 225
70 140 165
UNIT
V
V
W
W
W
1998 Jun 23
5