Philips 74hc hct390 DATASHEETS

INTEGRATED CIRCUITS
DATA SH EET
For a complete data sheet, please also download:
The IC06 74HC/HCT/HCU/HCMOS Logic Package Outlines
74HC/HCT390
Dual decade ripple counter
Product specification File under Integrated Circuits, IC06
December 1990
Philips Semiconductors Product specification
Dual decade ripple counter 74HC/HCT390

FEATURES

Two BCD decade or bi-quinary counters
One package can be configured to divide-by-2, 4, 5, 10,
20, 25, 50 or 100
Two master reset inputs to clear each decade counter individually
Output capability: standard
ICC category: MSI

GENERAL DESCRIPTION

The 74HC/HCT390 are high-speed Si-gate CMOS devices and are pin compatible with low power Schottky TTL (LSTTL). They are specified in compliance with JEDEC standard no. 7A.
The 74HC/HCT390 are dual 4-bit decade ripple counters divided into four separately clocked sections. The counters have two divide-by-2 sections and two divide-by-5 sections. These sections are normally used in a BCD

QUICK REFERENCE DATA

GND = 0 V; T
=25°C; tr=tf= 6 ns
amb
decade or bi-quinary configuration, since they share a common master reset input (nMR). If the two master reset inputs (1MR and 2MR) are used to simultaneously clear all 8 bits of the counter, a number of counting configurations are possible within one package. The separate clocks
CP0and nCP1) of each section allow ripple counter or
(n frequency division applications of divide-by-2, 4, 5, 10, 20, 25, 50 or 100.
Each section is triggered by the HIGH-to-LOW transition of the clock inputs (nCP0and nCP1). For BCD decade operation, the nQ0output is connected to the nCP1 input of, the divide-by-5 section. For bi-quinary decade operation, the nQ3 output is connected to the nCP0input and nQ0becomes the decade output.
The master reset inputs (1MR and 2MR) are active HIGH asynchronous inputs to each decade counter which operates on the portion of the counter identified by the “1” and “2” prefixes in the pin configuration. A HIGH level on the nMR input overrides the clocks and sets the four outputs LOW.
SYMBOL PARAMETER CONDITIONS
t
PHL
f
max
C C
/ t
I PD
propagation delay CL= 15 pF; VCC=5V
PLH
n
CP0 to nQ
n
CP1 to nQ
n
CP1to nQ
n
CP1to nQ
nMR to Q
maximum clock frequency nCP0,nCP
0 1 2 3
n
1
input capacitance 3.5 3.5 pF power dissipation capacitance per counter notes 1 and 2 20 21 pF
Notes
1. C
is used to determine the dynamic power dissipation (PD in µW):
PD
PD=CPD× V
2
× fi+∑ (CV
CC
2
× fo) where:
CC
fi= input frequency in MHz fo= output frequency in MHz (CV
2
× fo) = sum of outputs
CC
CL= output load capacitance in pF VCC= supply voltage in V
2. For HC the condition is VI= GND to V
CC
For HCT the condition is VI= GND to VCC−1.5 V
TYPICAL
UNIT
HC HCT
14 18 ns 15 19 ns 23 26 ns 15 19 ns 16 18 ns 66 61 MHz
December 1990 2
Philips Semiconductors Product specification
Dual decade ripple counter 74HC/HCT390

ORDERING INFORMATION

See
“74HC/HCT/HCU/HCMOS Logic Package Information”

PIN DESCRIPTION

PIN NO. SYMBOL NAME AND FUNCTION
1, 15 1
CP0, 2CP
0
clock input divide-by-2 section (HIGH-to-LOW, edge-triggered) 2, 14 1MR, 2MR asynchronous master reset inputs (active HIGH) 3, 5, 6, 7 1Q 4, 12 1
to 1Q
0
CP1, 2CP
3
1
flip-flop outputs
clock input divide-by-5 section (HIGH-to-LOW, edge triggered) 8 GND ground (0 V) 13, 11, 10, 9 2Q 16 V
0
CC
to 2Q
3
flip-flop outputs
positive supply voltage
.
Fig.1 Pin configuration. Fig.2 Logic symbol. Fig.3 IEC logic symbol.