Philips 74F07 Technical data

INTEGRATED CIRCUITS
74F07
Inverter/buffer drivers
Product data Supersedes data of 1992 Jul 24
 
2004 Mar 12
Philips Semiconductors Product data
74F07Hex inverter/buffer drivers (open-collector)
FEATURES
Open Collector output drive 64mA
High speed
TYPE
74F07 4.5ns 32mA
TYPICAL
PROPAGATION
DELA Y
TYPICAL SUPPL Y
CURRENT
(TOTAL)
12V output termination voltage
ORDERING INFORMATION
DESCRIPTION TYPE NUMBER PKG DWG #
14-pin plastic small outline package N74F07D SOT108–1 14-pin plastic dual in-line package N74F07N SOT27–1
PIN CONFIGURATIONS
74F07
GND
A0
1
Y0
2
A1
3
Y1
4
A2
5
Y2
6
14 13 12 11 10
9 87
SF00017
V
CC
A5 Y5 A4 Y4 A3 Y3
LOGIC SYMBOLS
V
= Pin 14
CC
GND = Pin 7
74F07
135 91113
A0 A1 A2 A3 A4 A5
Y0 Y1 Y2 Y3 Y4 Y5
46810
2
12
SF00019
2004 Mar 12
2
Philips Semiconductors Product data
Hex inverter/buffer drivers (open-collector)
IEC/IEEE SYMBOLS
74F07
1
3
5
9
11
13
LOGIC DIAGRAMS
A0
A1
A2
A3
A4
VCC = Pin 14 GND = Pin 7
A5
74F07
1
3
5
9
11
13
2
4
6
8
10
12
2
4
6
8
10
12
SF00021
Y0
Y1
Y2
Y3
Y4
Y5
SF00023
74F07
INPUT AND OUTPUT LOADING AND FAN OUT TABLE
PINS DESCRIPTION
An Data inputs 1.0/1.0 20µA/0.6mA Yn Data outputs OC/106.7 OC/64mA
NOTES:
1. One (1.0) FAST unit load is defined as: 20µA in the High state and 0.6mA in the Low state.
2. OC = Open Collector
FUNCTION TABLE
INPUTS OUTPUTS
An Yn
L L
H H
NOTES:
1. H = High voltage level
2. L = Low voltage level
74F (U.L.)
HIGH/LOW
LOAD VALUE
HIGH/LOW
2004 Mar 12
3
Philips Semiconductors Product data
Hex inverter/buffer drivers (open-collector)
ABSOLUTE MAXIMUM RATINGS
(Operation beyond the limit set forth in this table may impair the useful life of the device. Unless otherwise noted these limits are over the operating free air temperature range.)
SYMBOL
V
I T
V
V
I
OUT
OUT
amb
T
CC
IN
IN
stg
Supply voltage –0.5 to +7.0 V Input voltage –0.5 to +7.0 V Input current –30 to +5 mA Voltage applied to output in High output state –0.5 to 12 V Current applied to output in Low output state 128 mA Operating free air temperature range 0 to +70 °C Storage temperature range –65 to +150 °C
RECOMMENDED OPERATING CONDITIONS
SYMBOL
T
V
V V
V
I
CC
IH IL
I
Ik
OH
OL
amb
Supply voltage 4.5 5.0 5.5 V High-level input voltage 2.0 V Low-level input voltage 0.8 V Input clamp current –18 mA High-level output voltage 12 V Low-level output current 64 mA Operating free air temperature range 0 +70 °C
PARAMETER RATING UNIT
PARAMETER
74F07
LIMITS UNIT
MIN NOM MAX
2004 Mar 12
4