14. White Balance, Luminance Adjustment………...…….......63
15. Spare Parts List..………………….….………….................64
16. Different Parts List………………………………………75
17. General Product Specification…………………………….76
AND BE AWARE OF THE NECESSARY SAFETY PRECAUTIONS TO BE USED WHEN SERVICING
ELECTRONIC EQUIPMENT CONTAINING HIGH VOLTAGES.
CAUTION: USE A SEPARATE ISOLATION TRANSFOMER FOR THIS UNIT WHEN SERVICING
GB
3138 106 10522
1
19” LCD Color Monitor 190V7
Revision List
Version Release Date Revision History
A00 May.17, 2006 Initial release
A01 Jun.15, 2006
Add CTV Model 190V7FB/00,
190V7FB/69, 190V7FB/93 in Item 16
2
19” LCD Color Monitor 190V7
Important Safety Notice
Proper service and repair is important to the safe, reliable operation of all Philips Company** Equipment. The
service procedures recommended by Philips and described in this service manual are effective methods of
performing service operations. Some of these service operations require the use of tools specially design ed for the
purpose. The special tools should be used when and as recommended.
It is important to note that this manual contains various CAUTIONS and NOTICES which should be carefully read
in order to minimize the risk of personal injury to service personnel. The possibility exists that improper service
methods may damage the equipment. It is also important to unde rst and that the se CAUTIONS and NOTICE S ARE
NOT EXHAUSTIVE. Philips could not possibly know, evaluate and advise the service trade of all conceivable ways
in which service might be done or of the possible ha zardous conseq uences of each way. Consequently , Philips ha s
not undertaken any such broad evaluation. Accordingly, a servicer who uses a service procedure or tool which is
not recommended by Philips must first satisfy himself thoroughly that neither his safety nor the safe operation of
the equipment will be jeopardized by the service method selected.
* * Hereafter throughout this manual, Philips Company will be referred to as Philips.
WARNING
Use of substitute replacement parts, which do not have the same, specified safety characteristics may create
shock, fire,
or other hazards.
Under no circumstances should the original design be modified or altered without written permission from Philips.
Philips
assumes no liability, express or implied, arising out of any unauthorized modification of design.
Servicer assumes all liability.
FOR PRODUCTS CONTAINING LASER:
DANGER-Invisible laser radiation when open. AVOID DIRECT EXPOSURE TO BEAM.
CAUTION-Use of controls or adjustments or performance of procedures other than those specified herein may
result in hazardous radiation exposure.
CAUTION -The use of optical instruments with this product will increase eye hazard.
TO ENSURE THE CONTINUED RELIABILITY OF THIS PRODUCT, USE ONLY ORIGINAL MANUFACTURER'S
REPLACEMENT PARTS, WHICH ARE LISTED WITH THEIR PART NUMBERS IN THE PARTS LIST SECTION
OF THIS SERVICE MANUAL.
Take care during handling the LCD module with backlight unit
-Must mount the module using mounting holes arranged in four corners.
-Do not press on the panel, edge of the frame strongly or electric shock as this will result in damage to the screen.
-Do not scratch or press on the panel wi th any sharp object s, su ch as pen cil or pen a s this may result in damage to
the
panel.
-Protect the module from the ESD as it may damage the electronic circuit (C-MOS).
-Make certain that treatment person’s body is grounded through wristband.
-Do not leave the module in high temperature and in areas of high humidity for a long time.
-Avoid contact with water as it may a short circuit within the module.
-If the surface of panel becomes dirty, please wipe it off with a soft material. (Cleaning with a dirty or rough cloth
may damage the panel.)
3
19” LCD Color Monitor 190V7
1. Monitor Specifications
Screen type Active matrix - TFT LCD
Panel Type LM190E03 (LPL)
LCD Panel
Input
Display Colors 16.2 M
Contrast Ratio 700:1
White Luminance 300cd/m2
Video dot rate 140 MHz
Maximum Resolution
Recommended Resolution 1280 x 1024 at 60Hz (digital input)
Size 481.9 mm (19.0")
Pixel pitch 0.294mm(H) x 0.294mm(V)
Viewable angle (CR>10)
Response time 8ms (type)
Video
Separate Sync
Horizontal Frequency 30kHz – 83kHz
Vertical refresh rate 56 - 76Hz
1280 x 1024 at 75Hz (analog input)
1280 x 1024 at 75Hz (digital input)
Plug & Play VESA DDC2B
Power Consumption
Input Connector
Input Video Signal 0.7 Vp-p, input impedance, 75 ohm @DC
Tilt -5° ~ 25°
Maximum Screen Size
Power Source
Environmental
Considerations
Weight (Net) 5.5kg
Cabinet color 190V7FB: Black
Power on: < 34 W
Power off: < 1 W
D-Sub 15pin
D-DVI 24 pin
Horizontal: 376.32mm;Vertical: 301.056 mm
100-240 VAC, 50/60 Hz
Operating Temp: 5°C to 40°C
Operating Humidity: 20% to 80%
Storage Temp.: -20°C to 60°C
4
19” LCD Color Monitor 190V7
)
2. LCD Monitor Description
The LCD monitor will contain a main board, PWPC board, keypad board, which house the flat panel control logic,
brightness control logic and DDC.
The power board will provide AC to DC Inverter voltage to drive the backlight of panel and the main board chips
each voltage.
Monitor Block Diagram
PWPC board
(Included: adapter and
inverter
AC-IN
100-240V
CCFL Drive.
Main Board
Keyboard
Flat Panel and
CCFL backlight
RS232 Connector
For white balance
adjustment in factory
mode
Video signal, DDC
Host Computer
5
19” LCD Color Monitor 190V7
3. Operation instructions
3.1 General Instructions
Press the power button to turn the monitor on or off. The other control buttons are located at front panel of the
monitor. By changing these settings, the picture can be adjusted to your personal preferences.
The power cord should be connected.
-
Connect the video cable from the monitor to the video card.
-
Press the power button to turn on the monitor, the power indicator will light up.
-
3.2 Control Buttons
Front View
6
19” LCD Color Monitor 190V7
7
19” LCD Color Monitor 190V7
3.3 Adjusting the Picture
This is a feather in all Philips LCD monitors. It allows an end user to adjust screen performance of the monitors
directly through an on-screen instruction window. The user interface provides user-friendliness and ease-of-use
when operating the monitor.
When you press the
window will pop up and you can then start making adjustments to your monitor’s various features. Use the
button on the front control of your monitor, the On-Screen Display (OSD) main controls
or
the
keys to make your adjustments.
The OSD tree
Below is an overall view of the structure of the On-Screen Display. Y ou can use this as a reference whe n you want to
work your way around the different adjustments later on.
8
19” LCD Color Monitor 190V7
9
19” LCD Color Monitor 190V7
10
19” LCD Color Monitor 190V7
3.4 Connecting to the PC
1) Connect the power cord to the back of the monitor firmly. (Philips has pre-connected) VGA cable for the first
installation.)
2) Connect to PC
(a) Turn off your computer and unplug its power cable.
(b) Connect the monitor signal cable to the video connector on the back of your computer.
(c) Plug the power cord of your computer and your monitor into a nearby outlet.
(d) Turn on your computer and monitor. If the monitor displays an image, installation is complete.
11
19” LCD Color Monitor 190V7
4. Input/Output Specification
4.1 Input Signal Connector
4.1.1 VGA Connector
Pin NO. Description Pin NO.Description
1. Red Video input 9. DDC +5V
2. Green Video input (SOG) 10. Logic GND
3. Blue Video input 11. Ground
4. Sense (GND) 12. Serial data line (SDA)
5. Cable Detect 13. H.sync /H + V.sync
6. Red Video Ground 14. V.Sync
7. Green Video Ground 15. Data Clock Line (SCL)
8. Blue Video Ground
VGA Connector layout
4.1.2 DVI Connector
Pin NO. Description Pin NO.Description
1. T.M.D.S.Data2- 13. No connect
2. T.M.D.S.Data2+ 14. + 5V Power
3. T.M.D.S.Data2/4 Shield 15. Ground (for +5V)
4. No connect 16. Hot Plug Detect
5. No connect 17. T.M.D.S.Data0-
6. DDC Clock 18. T.M.D.S.Data0+
7. DDC Data 19. T.M.D.S.Data0/5 Shield
8. No connect 20. No connect
9. T.M.D.S.Data1- 21. No connect
10. T.M.D.S.Data1+ 22. T.M.D.S. Clock Shield
11. T.M.D.S.Data1/3 Shield 23. T.M.D.S. Clock +
12. No connect 24. T.M.D.S. Clock DVI Connector layout
12
19” LCD Color Monitor 190V7
4.2 Factory Preset Display Modes
13
19” LCD Color Monitor 190V7
4.3 Pixel Defect Policy
14
19” LCD Color Monitor 190V7
15
19” LCD Color Monitor 190V7
16
19” LCD Color Monitor 190V7
5. Block Diagram
5.1 Monitor Exploded View
17
19” LCD Color Monitor 190V7
5.2 Software Flow Chart
1
Y
2
N
4
3
5
Y
6
7
9
10
Y
N
12
N
N
8
Y
N
11
N
13
Y
14
18
N
19
Y
18
15
17
Y
N
16
Y
19” LCD Color Monitor 190V7
1) MCU Initializes.
2) Is the EEprom blank?
3) Program the EEprom by default values.
4) Get the PWM value of brightness from EEprom.
5) Is the power key pressed?
6) Clear all global flags.
7) Are the AUTO and SELECT keys pressed?
8) Enter factory mode.
9) Save the power key status into EEprom.
Turn on the LED and set it to green color. Scalar
initializes.
10) In standby mode?
11) Update the lifetime of back light.
12) Check the analog port, are there any signals coming?
13) Does the scalar send out an interrupt request?
14) Wake up the scalar .
15) Are there any signals coming from analog port?
16) Display "No connection Check Signal Cable" message. And go into standby mode after the message
disappears.
17) Program the scalar to be able to show the coming mode.