Philips 157263 User Manual

Ceramalux®High Pressure Sodium Non-Cycling 1000 Watt ED-25 (Clear) Lamp
featuring ALTO®Lamp Technology
Ordering Information
Ordering Code C1000S52/ALTO NC HPS ANSI Designation S52 Product Number 157263 Description High Pressure Sodium
TCLP*Compliant Non-Cycling
Package Quantity 6
Physical Characteristics
Bulb Size ED-25 Bulb Finish Clear Base Mogul Screw Max. Overall Length (MOL) 15.08" (383mm) Light Center Length (LCL) 8.74" (222mm) Arc Length 8.5" (215mm) Arc Tube Length 9.6" (243mm) Arc Tube Material Aluminum Oxide Operating Position Universal Maximum Permissible Bulb Temperature 400ºC (752°F) Maximum Permissible Base Temperature 210ºC (410°F) Maximum Bulb to Base Eccentricity 3° Maximum Arc Tube to Base Eccentricity
Operating Characteristics (Photometric)
Approximate Initial Lumens Approximate Mean Lumen Rated Average Life, Hours Correlated ColorTemperature (CCT) 2100 K CIE Chromaticity Approximate x-.515, y-.420 Color Rendering Index (CRI) 20 Efficacy (LPW) 130
1
2
3
130,000 117,000 30,000
Operating Position
Universal
TCLP*Characteristics
Toxicity Characteristic Leaching Procedure (Federal TCLP) Results
Hg EPA Limit (mg/l) Max 0.200 5.00 C1000S52/ALTO NC HPS 0.062 <0.31
Mercury (mg/lamps) Max 11
Pb
Philips Lighting Company 200 Franklin Square Drive P.O. Box 6800 Somerset, NJ 08875-6800 1-800-555-0050
Division of Philips Electronics North America Corporation
A
pdated 1/07 TDS-157263
U
www.philips.com
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050
A Division of Philips Electronics Ltd.
Ceramalux®High Pressure Sodium Non-Cycling 1000 Watt ED-25 (Clear) Lamp featuring ALTO
lectrical Data
E
Lamp Watts (Nominal). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
Lamp Operating Voltage (rms) (Nominal) . . . . . . . . . . . . . . . . . . 275V
Initial Lamp Voltage Range (rms). . . . . . . . . . . . . . . . . . . . . . . . . . 250–300V
Lamp Operating Current (Amps) (rms) (Nominal). . . . . . . . . . 4.7
Maximum Lamp Star ting Current (Amps)(rms) . . . . . . . . . . . . . 8.0
Lamp Current Crest Factor (Maximum) . . . . . . . . . . . . . . . . . . . 1.8
Warm-up Time to 80% of Output . . . . . . . . . . . . . . . . . . . . . . . . 7 Minutes
Re-strike Time for Hot Lamp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Minutes
Ballast Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI S52
Ballast Open Circuit Voltage (Minimum): . . . . . . . . . . . . . . . . . . 456 Vrms
Pulse Peak Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2675
Pulse Width @ 90% Peak. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 µs Minimum at 2700 Volts
Pulse Frequency (Minimum)
Lag Ballast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 per Cycle
Lead Circuit Ballast. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 per Cycle
Minimum Operating Temperature. . . . . . . . . . . . . . . . . . . . . . . . . -30°C
Reference Ballast Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77(ohms) minimum at 480V
Maximum Lamp Watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Minimum Lamp Watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 750
Maximum Voltage Increase by Fixture . . . . . . . . . . . . . . . . . . . . . 25V
Footnotes:
1) Measured at 100 hours of life in ver tical and horizontal positions.
2) Approximate mean lumen output at 40% of lamp rated average life. Measured in ver tical and hor izontal oper ating positions. ) Rated average life is the life obtained, on the average, from large representative groups of lamps in laborator y tests under controlled conditions at 10 or more operating hours per start.
3
t is based on survival of at least 65% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.
I
*The TCLP is the US EPA’sToxicity Characteristic Leaching Procedure.
WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS
for Ceramalux High Pressure Sodium Lamps
“WARNING:These lamps must be operated in fixtures designed for use with
R
High Pressure Sodium lamps.The fixture wattage rating must match the wattage indicated on the outer glass bulb. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter.A partial vacuum in the outer bulb may cause glass to fly if the glass is struck. Operating the lamp improperly may result in
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
1) If the outer glass bulb is broken, shut off power immediately and remove the lamp
after it has cooled.
2) Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within
voltage limits recommended by ballast manufacturer.
A. Operate lamp only within specified limits of operation. B. For total supply load refer to ballast manufacturers electrical data.
3) Protect lamp base, socket and wiring against moisture, corrosive atmospheres and
excessive heat.
4) Replace the lamp if the outer glass bulb has been scratched, cracked or damaged
in any way.
5) If a lamp bulb support is used, be sure to insulate the support electrically so as to
avoid possible decomposition of the bulb glass.
6) Do not use this lamp in a fixture which redirects a substantial portion of the
energy toward the arc tube and its immediate vicinity, as this may lead to very early lamp failure.
7) Take care in handling and disposing of lamps. If arc tube is broken, avoid skin
contact with any of the contents or fragments.
8) The arc tube of this lamp contains sodium and mercury. Dispose of in accordance
with federal, state and local requirements.
Subject to change without notice)
(
®