Philips 157255 User Manual

Ceramalux®High Pressure Sodium Non-Cycling
53/4"
93/4"
Approximate Lumen Maintenance
Approximate Survival Curve
20 40 60
80
100
0
0
Percent of Rated Average Life
6,000 12,000 18,000
24,000
30,000
0
Operating Hours
Percent of Rated Average Life Operating Hours
60
80
70
90
100
%
Percent – Approx.Initial Lumens
20 40 60
80
100
0
0
6,000 12,000 18,000
24,000
30,000
0
60
80
70
90
100
%
Percent – Approx.Sur vival
200 Watt ED-18 (Clear) Lamp
featuring ALTO®Lamp Technology
Ordering Information
Ordering Code C200S66/ALTO NC HPS ANSI Designation S66 Product Number 157255 Description High Pressure Sodium
TCLP*Compliant Non-Cycling
Package Quantity 12
Physical Characteristics
Bulb Size ED-18 Bulb Finish Clear Base Mogul Screw Max. Overall Length (MOL) 9.75" (248mm) Light Center Length (LCL) 5.75" (146mm) Arc Length 2.6" (66mm) Arc Tube Length 3.5" (91mm) Arc Tube Material Aluminum Oxide Operating Position Universal Maximum Permissible Bulb Temperature 400ºC (752°F) Maximum Permissible Base Temperature 210ºC (410°F) Maximum Bulb to Base Eccentricity 3° Maximum Arc Tube to Base Eccentricity
Operating Characteristics (Photometric)
Approximate Initial Lumens Approximate Mean Lumen Rated Average Life, Hours Correlated ColorTemperature (CCT) 2100 K CIE Chromaticity Approximate x-.530, y-.405 Color Rendering Index (CRI) 22 Efficacy (LPW) 110
1
2
3
22,000 19,800 30,000
Operating Position
Universal
TCLP*Characteristics
Toxicity Characteristic Leaching Procedure (Federal TCLP) Results
Hg
Pb EPA Limit (mg/l) Max 0.200 5.00 C200S66/ALTO NC HPS 0.074 0.0
Mercury (mg/lamps) Max 6.6
Philips Lighting Company 200 Franklin Square Drive P.O. Box 6800 Somerset, NJ 08875-6800 1-800-555-0050
Division of Philips Electronics North America Corporation
A
pdated 1/07 TDS-157255
U
www.philips.com
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050
A Division of Philips Electronics Ltd.
Ceramalux®High Pressure Sodium Non-Cycling 200 Watt ED-18 (Clear) Lamp featuring ALTO
lectrical Data
E
Lamp Watts (Nominal). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Lamp Operating Voltage (rms) (Nominal) . . . . . . . . . . . . . . . . . . 100V
Initial Lamp Voltage Range (rms). . . . . . . . . . . . . . . . . . . . . . . . . . 85–115V
Lamp Operating Current (Amps) (rms) (Nominal). . . . . . . . . . 2.4
Maximum Lamp Star ting Current (Amps)(rms) . . . . . . . . . . . . . 3.6
Lamp Current Crest Factor (Maximum) . . . . . . . . . . . . . . . . . . . 1.8
Warm-up Time to 80% of Output . . . . . . . . . . . . . . . . . . . . . . . . 5 Minutes
Re-strike Time for Hot Lamp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Minutes
Ballast Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI S66
Ballast Open Circuit Voltage (Minimum): . . . . . . . . . . . . . . . . . . 198 Vrms
Pulse Peak Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2225
Pulse Width @ 90% Peak. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1µs Minimum at 2250 Volts
Pulse Frequency (Minimum)
Lag Ballast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 per Cycle
Lead Circuit Ballast. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 per Cycle
Minimum Operating Temperature. . . . . . . . . . . . . . . . . . . . . . . . . -30°C
Reference Ballast Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74.6(ohms) minimum at 220V
Maximum Lamp Watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
Minimum Lamp Watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Maximum Voltage Increase by Fixture . . . . . . . . . . . . . . . . . . . . . 10V
Footnotes:
1) Measured at 100 hours of life in ver tical and horizontal positions.
2) Approximate mean lumen output at 40% of lamp rated average life. Measured in ver tical and hor izontal oper ating positions. ) Rated average life is the life obtained, on the average, from large representative groups of lamps in laborator y tests under controlled conditions at 10 or more operating hours per start.
3
t is based on survival of at least 65% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.
I
*The TCLP is the US EPA’sToxicity Characteristic Leaching Procedure
WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS
for Ceramalux High Pressure Sodium Lamps
“WARNING:These lamps must be operated in fixtures designed for use with
R
High Pressure Sodium lamps.The fixture wattage rating must match the wattage indicated on the outer glass bulb. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter.A partial vacuum in the outer bulb may cause glass to fly if the glass is struck. Operating the lamp improperly may result in
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
1) If the outer glass bulb is broken, shut off power immediately and remove the lamp
after it has cooled.
2) Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within
voltage limits recommended by ballast manufacturer.
A. Operate lamp only within specified limits of operation. B. For total supply load refer to ballast manufacturers electrical data.
3) Protect lamp base, socket and wiring against moisture, corrosive atmospheres and
excessive heat.
4) Replace the lamp if the outer glass bulb has been scratched, cracked or damaged
in any way.
5) If a lamp bulb support is used, be sure to insulate the support electrically so as to
avoid possible decomposition of the bulb glass.
6) Do not use this lamp in a fixture which redirects a substantial portion of the
energy toward the arc tube and its immediate vicinity, as this may lead to very early lamp failure.
7) Take care in handling and disposing of lamps. If arc tube is broken, avoid skin
contact with any of the contents or fragments.
8) The arc tube of this lamp contains sodium and mercury. Dispose of in accordance
with federal, state and local requirements.
Subject to change without notice)
(
®
Lamp Technology
Loading...