Association
This device supports 2 association groups which every group has
eight node support.
To build/disable association between devices,
1. Have the Z-Wave controller entered association mode.
2. Rotate PSR07 to area A then touch the button.
Group 1 is for receiving the report message, like the battery level.
Group 2 is for controlling, the device will send Basic Set command
to this group.
Timing Report
The device supports the timing unsolicited report of the status.
• Battery level report: Every 6 hours report once in default.
It could be changed by setting the configuration NO. 10.
• Low battery report: When the battery level is too low, every 30
minutes will report once.
Z-WaveTM Notification
After the device adding to the network, it will wake-up once per
day in default. When it wake-up it will broadcast the “Wake Up
Notification” message to the network, and wake-up 10 seconds for
receive the setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes. If the user want to wake-up the device
immediately, please rotate to area A and pressing the touch button
once. The device will wake-up for 10 seconds every single time.
Configuration
NO. Name Size
(Byte)
Def. Valid
Values
Description
1 Basic Set
OFF level
1 0x00 0x00~0x6
3
Control the value
represented by the left-side
in area D. E.g. Setting this
configuration to 0x0F means
range of Command Basic Set
value start from 0x0F
2 Basic Set
ON level
1 0x63 0x01~0x6
3
Control the value
represented by the right-side
in area D. E.g. Setting this
configuration to 0x1E means
range of Command Basic Set
value start from 0x1E
10
Auto
Report
Battery
Time
1 12 1~127
The interval time for auto re-
porting the Battery level. 0
means turn off auto report
battery.
The default value is 12.
25
Percentage
Set Method 1 0x00 0x00,0x01
Dimmer setting method.
0 : Auto send Command Ba-
sic Set after rotating.
1 : Send Command Basic Set
by touching key after rotat-
ing
3