Philio Technology Corporation PSA03 User Manual

The Doorlock PSA03 is Base on Z-Wave
TM
technology. It is the Z-WaveTM plus product, it supports the security, OTA... Those newest features of the Z-WaveTM technology. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.
Notice: if user use some command, it have to check device is
security bootstrap otherwise some command cannot increment.
1
PSA03 Smart DoorLock
2345678
I. Z-Wave function
“Enter PC” is enter “0000”(default)
function description
Add
1. check Z-Wave
TM
Controller entered
inclusion mode.
2.Press the Add/Remove function
3.After adding successful, it will have twice beep sounds. if inclusion fail it will have five beep.
Notice 1: if you reset doorlock, you have to do OPERATING INSTRUCTION no.1(door handling identification process)
Notice 2: if Door lock in learn mode,device can stop on operation setting mode,until success include or 60s time out.
Remove
1. check Z-Wave
TM
Controller entered
exclusion mode.
2.Press the Add/Remove function
3After removing successful, it will have twice beep sounds. if remove fail it will have five
beep.
Notice 1 : if you reset doorlock ,you have to do OPERATING INSTRUCTION no.1(door handling identification process )
Reset
1.Press the Restore function in section OPERATING INSTRUCTION no.10
2.Device can send reset locally notification
note : Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Lock 1.Z-WaveTM Controller use Command Class
Door Lock
2. Use Command Door Lock Operation Set
3.Set value to 0xFF, it means door secured.
unlock 1.Z-WaveTM Controller use Command Class
Door Lock
2. Use Command Door Lock Operation Set
3.Set value to 0x00, it means door unsecured.
Add usercode
1. Z-WaveTM Controller use Command Class User Code
2. Use Command User Code Set
3. Set User code ID, User code Status, Usercode note: User code ID range is 1~30, User code Status 0x01, Usercode length is 4~10,
Remove usercode
1. Z-WaveTM Controller use Command Class User Code
2. Use Command User Code Set
3. Set User code ID, User code Status,
9
Usercode note: User code ID range is 1~30, User code Status 0x00, Usercode length is 4~10,
S2 inclusion 1.User can get our Full DSK string on my
battery cover notice: underline five digit is PINcode
Ex: mydsk 10190-35370-09760-44693-14490-09979­57572-04945
2.Let Gateway in inclusion mode, User can key first five digit on our App UI, then if first five digit is correct, S2 inclusion can success.
Smart start
1.User can scan our Qrcode on our app, and then if device power on , device can auto include
2.SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of minutes On in the network vicinity
*notice1:user must check device have be exclude. *notice2:the QR Code is printed on a material that resists being removed. *notice3:Qrcode is button of doorlock,
association The device support two group
Group 1 name: Lifename Group 1 command list: COMMAND_CLASS_BATTERY, COMMAND_CLASS_DOOR_LOCK_V2, COMMAND_CLASS_DEVICE_RESET_LOCA LLY, COMMAND_CLASS_NOTIFICATION_V3,
10
max node of group:5 Group 2 name: Doorlock Op Group 2 command list: COMMAND_CLASS_DOOR_LOCK_V2, max node of group:5
Z-Wave Configuration Settings
NO Name Def Valid description
1 RFvoice
setting
0x01 0x00 &
0x01
If set value to 0x00, RF setting can let voice turn off
Notice 1: Always REMOVE a Z-WaveTM device before trying to add it to a Z-WaveTM network.
Notice 2: if battery level less than 4.3V, doorlock can run shut down mode. Touch panel operation can be stop until change battery.
Notice 3: keypad locking function will be invalid when usercode all deleted, the lock can be operated by key during that time.
Notice 4: This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
II. Z-WaveTM Message Report
When you lock or unlock the door, the device will report the door lock status as event to controller.
* Door Lock Status Report:
When you lock or unlock the door, the device will unsolicited to send the report to the nodes in the group 1.
Door Lock Operation Report (V2)
Unlock Current Door Lock Mode: Door Unsecured=00 Lock Current Door Lock Mode: Door Secured=FF unknow Current Door Lock Mode: Door Secured=FE
VIII. Over the Air Firmware Update
The device supports the Z-Wave firmware update via OTA. Let the Z-WaveTM Controller into the firmware update mode, chose the hex file to update. Wait for 10~15 minutes. At that time, please don't remove the battery, otherwise it will cause the firmware broken, and the device will no function. Result will show in Z-WaveTM Controller log.
X. Z-Wave Supported Command Class
COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_SUPERVISION, COMMAND_CLASS_TRANSPORT_SERVICE_V2 COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_VERSION*
COMMAND_CLASS_NOTIFICATION*
COMMAND_CLASS_MANUFACTURER_SPECIFIC*
11
COMMAND_CLASS_DEVICE_RESET_LOCALLY* COMMAND_CLASS_POWERLEVEL* COMMAND_CLASS_BATTERY* COMMAND_CLASS_DOOR_LOCK* COMMAND_CLASS_USER_CODE* COMMAND_CLASS_ASSOCIATION_V2* COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2* COMMAND_CLASS_ASSOCIATION_GRP_INFO* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2*
* Command Class Requires Security
XI. Simple Troubleshooting
1. After the installation of lockset and batteries, the door cannot be locked, and three short beeps are emitted when you press the Programming button.
Causes: The door-handling identifying process is not yet complete. Solution: Please execute the door-handling identifying process as soon as the installation of the lockset is completed.
2. After the installation of the lockset and batteries, no responses when you press any button (no sounds are emitted, and the back light does not work).
Cause: It could be a problem caused by the batteries or the improper connection of the cable. Solution: Check to see if the battery polarities have been reversed or if the battery is dead. If so, please reinstall or change the battery. If not, please check if the cable is appropriately connected.
3. Fail in the first execution of the door-handling identifying process (the red-light flashes three times, and three short beeps are emitted).
Cause: Wrong door-handling or change of the door-handling in the memory. Solution: Press the R button to restore the system to factory default setting and re-execute door-handling identifying process.
4. Although succeeded in the first execution of the door-handling identifying process, the latch does not work. (Feeling that the motor runs powerlessly, the latch bolt is stuck, and the turn-piece inside cannot be rotated).
Cause: Low battery. Solution: Please replace with new batteries.
5. The functioning has been normal, but suddenly, the latch bolt locks up, and the turn piece inside cannot be rotated, not even with key.
Cause: The detection of latch bolt position is abnormal. Solution: Please take out one battery first, then press any button on the front panel for electric discharge, and put the battery back next. The latch bolt will automatically re-detect its position subsequently. Attention: When the latch gets stuck frequency, please check if the opening of the strike aims at the central position of the latch bolt, if the latch bolt can stretch out freely, or if the hinges are deformed or tilted.
6. The door can be locked normally, but three shorts beeps are heard and the door would not unlock when the user code is entered and the programming button is pressed.
Cause: The functioning of the micro-switch is abnormal. Solution: Please unlock the door with the keys first and then contract
12
the distributor for inspection and maintenance.
7. While the door is closed, you hear the latch bolt coming out when you press the programming button to lock the door; however, three shorts beeps are emitted. Conversely, while the door is open, no beeps are emitted when locking the latch bolt.
Cause: (1) The depth of latch bolt hole is insufficient. (2) The latch bolt is not aimed at the opening of the strike. Solution: (1) Please dig the latch bolt hole for the strike deeper (min. Depth of 2.5 cm). (2) Please adjust the strike to the appropriate position.
Specification
Rated Voltage DC6V; (Battery AA x 4)
Battery type Alkaline Battery AA (LR6)
Operating Temperature 0°C - 40°C
Location In door use
Frequency Range 868.40MHz & 869.85MHz / EU
908.4MHz & 916.0MHz / USA
922-927MHz / JAPAN
RF Maximum Power (Peak) +5dBm (Peak)
RF Maximum Power (Average) -10dBm (Average)
Transmission Range Minimum 40 m in door 100m
outdoor line of sight
Modulation Type FSK (Frequency-Shift Keying)
** Specifications are subject to change and improvement without notice.
FCC ID: RHHPSA03
CAUTION Risk of explosion if battery is replaced by an incorrect type. Dispose of used battery according to the instructions.
Choosing a Suitable Location
1. Do not locate the Module facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Module is 0°C~40°C.
3. Do not locate the Module where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.
Disposal
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was
13
purchased. They can take this product for environmental safe recycling.
Philio Technology Corporation 8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257, Taiwan(R.O.C)
w ww.philio-tech.com
FCC Interference Statement This equipment has been tested and found to comply with the lim­its for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the in­structions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or tele­vision reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the fol­lowing measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly ap­proved by the party responsible for compliance could void the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
14