IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the
desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the
same logic applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 2: Basic Set Level
Setting the BASIC command value to turn on the light.
Size: 1 Byte, Default Value: -1
Setting Description
-128 - 127 Basic command value to turn on the light.
Parameter 3: PIR Sensitivity
PIR sensitivity setting.0 means disable the PIR motion. High sensitivity means can detected long distance,but if there is more noise signal in the environment, it will
re-trigger too frequency.
Size: 1 Byte, Default Value: 80
Setting Description
0 - 99 PIR sensitivity setting.
Parameter 6: Multi-Sensor Function Switch
Multisensor function switch.
Size: 1 Byte, Default Value: 5
Setting Description
8 When Bit2 is 0(Enable), Are the device and the lighting in the same room? 0:In the same room(Default), 1:In the
different room.
16 Disable delay 5 seconds to turn off the light,when door/window closed.(1:Disable, 0:Enable)
32 Disable auto turn off the light,after door/window opened to turn on the light.(1:Disable, 0:Enable)
Parameter 7: Customer Function
Size: 1 Byte, Default Value: 4
Setting Description
2 Enable sending motion OFF report.(0:Disable, 1:Enable)
4 Enable PIR suoer sensitivity mode.
16 Notification Type,0:Using Notification Report. 1: Using Sensor Binary Report.
32 Disable Multi CC in auto report.(1:Disable, 0:Enable)
64 Disable to report battery state when the device triggered.(1:Disable, 0:Enable)
Parameter 8: PIR Re-Detect Interval Time
In the normal mode, after the PIR motion detected, setting the re-detect time.8 seconds per tick,default tick is 3(24 seconds).Setting the suitable value to prevent
received the trigger signal too frequently. Also can save the battery energy.
Size: 1 Byte, Default Value: 3
Setting Description
1 - 127 Re-detect time
Parameter 9: Turn Off Light Time
After turn on the light,setting the delay time to turn off the lighting when the PIR motion to turn off the lighting when the PIR motion is not detected.8 seconds per
tick,default tick is 4(32 seconds).
Size: 1 Byte, Default Value: 4
Setting Description
0 - 127 Delay time to turn off the lighting when the PIR motion is not detected.
Parameter 10: Auto Report Battery Time
The Interval time for auto report the battery level.0 means turn off auto report battery.The default value is 12.The tick time can setting by the configuration NO.20.
Size: 1 Byte, Default Value: 12