Pfannenberg Quadro F12-3G/3D ATEX Catalog Page

PRODUCTS EX SIGNALING DEVICES
The Quadro F12 3G/3D flashing light is designed for tough demands under industrial conditions and is usable as a visual alarm. The flashing
light, which is suitable for use both indoors and out, generates bright light impulses with a high attention-drawing effect.
• For use in potentially explosive areas in Zone 2 as per EN 60079-10 and Zone 22 as per EN 61241-10.
• The requirements of the EN 60079-0, EN 60079-15, EN 61241-0, EN 61241-0 (2007) and EN 61241-1 (2005) standards are fulfilled.
• Usable for gases in the temperature classes T1, T2, T3 and T4, as well as for non-conductive dusts, provided that the surface temperature of the equipment does not exceed +105 °C.
IP 66
protection system
IK08
impact-proof housing
+45 °C
–20 °C
operating temperature
10
Years
warranty
PRODUCT Quadro F12-3G/3D ATEX
Rated voltage
Operating range 195–253 V 95–127 V 18–30 V
Nominal current consumption 90 mA 140 mA 360 mA
Initial current limited to <7 A / 150 µs <7 A / 150 µs <5 A / 2 ms
Explosion protection
Category (area of use)
Conformity to standards Guideline 94/9/EG (ATEX 100a)
Testing body Pfannenberg
X: according to the requirements of prDIN EN 60 079-0, DIN EN 61241-0 (2007) and DIN EN 61241-1 (2005),
Special conditions
Flash rate 0.83 Hz = 50 flashes/min
Flash energy 7.5 J
Light intensity (DIN 5037)
Operating temperature –20 °C ... +45 °C
Storage temperature –40 °C ... +70 °C
Relative humidity 100 %
Protection system (EN 60529) IP 66; mounting arbitrary
Impact resistance (EN 50102) IK08
Protection class II
Duty cycle 100 %
Service life of the light source light emission still 70 % after 8,000,000 flashes
Material
Connecting terminals cage clamp terminal 0.08–2.5 mm
Cable entry 2x M20 sideways (1x blanking plug, 1x cable connection)
Weight 600 g
1
with a clear lens
1
lens
housing polycarbonate (PC), RAL 7035 (optionally RAL 3000)
230 V 115 V 24 V
AC 50 | 60 Hz AC 50 | 60 Hz DC
II 3G Ex nR IIC T4 –20 °C ≤ Ta ≤ +45 °C
II 3D Ex tD A22 IP66 T105 °C –20 °C ≤ Ta ≤ +45 °C
3G (Zone 2)
3D (Zone 22)
the equipment is suitable for applications with a low degree of mechanical danger.
It must therefore be ensured that the light is mounted with sufficient protection against impacts.
A protective cage is not mandatory.
84 cd
polycarbonate (PC)
2
DIMENSIONS
80
130
25
130
mounting screws e. g. 4x M4 x 20
CONNECTION DIAGRAMS
AC DC
mounting holes
113
Ø 4.5
113
blanking plug M20 x 1.5
cable connection
M20 x 1.5
for supplying additional
flashing lights
ARTICLE NO.
Lens colour 230 V AC 24 V DC
21041101008 21041801008
21041103008 21041803008
21041104008 21041804008
21041105008 21041805008
Article numbers for other colours and voltages on request.
MANUFACTURER’S DECLARATION
We hereby declare that the explosion-protected means of alarm with the type designation Quadro F12 3G/3D has been developed and manufactured in accordance with the requirements as per EN 50014.
This declaration is based on compliance with the following regulations and standards:
DIN EN 60079-0 Electrical equipment for areas at risk of gas explosions – Part 0: General requirements DIN EN 60079-15 Electrical equipment for areas at risk of explosions – Part 15: type of protection type “n” DIN EN 61241-0 Electrical equipment for use in areas with combustible dust – General requirements DIN EN 61241-1 Electrical equipment for use in areas with combustible dust – protection by enclosure “tD” DIN EN 60598-1 Lights – Part 1: General requirements and tests DIN EN 60947-1 Low-voltage switchgear – Part 1: General specifications DIN EN 60529 Types of protection by enclosure (IP code) DIN EN 50102 Types of protection by enclosure for electrical equipment against external mechanical stresses (IK code) DIN EN 61000-6-2 Electromagnetic compatibility (EMC) – Part 6-2: Generic standards, noise immunity for industrial areas DIN EN 61000-6-3 Electromagnetic compatibility (EMC) – Part 6-3: Generic standards, interference emission for residential areas, business and commercial areas as well as small companies DIN EN 981 Machine safety – System of acoustic and visual alarm signals and information signals ISO 11429 System of acoustic and visual alarm signals and information signals UVV-BGV A3(VBG4) Electrical plants and equipment GSGV German Appliance Safety Act
The Quadro F12 3G/3D flashing lights are approved for use in potentially explosive areas in Zones 2 and 22 as per 94/9/EU.
Quadro F12-3G/3D ATEX
EX SIGNALING DEVICES
Loading...