Visual signaling devices
SPECTRA series LED multifunction lights
P 400 LDA (Ø 140 mm) / P 300 LDA (Ø 100 mm)
|
|
|
|
|
|
|
|
|
|
• LED multifunction lights for extreme requirements |
|
||||||||
|
|
|
|
|
|
|
|
|
|
• energy-saving and durable thanks to the use of maintenance-free |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
LED technology |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• as standard with on-site selectable signalling mode (9 different modes) |
|||||||||
|
|
|
|
|
|
|
|
|
|
• externally switchable signaling mode (for DC versions only) |
|||||||||
|
|
|
|
|
|
|
|
|
|
• large variety of mounting methods due to modular design principle: |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
– surface-mounted devices for mounting directly or on a wall bracket |
||||||||
|
|
|
|
|
|
|
|
|
|
|
or a tubular stand |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
– also for exposed installation locations through combination of |
||||||||
|
|
|
|
|
|
|
|
|
|
|
wall bracket and tubular stand |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
– cable entry at the side or through the base of the housing |
||||||||
|
|
|
|
|
|
|
|
|
|
• durable, sturdy and functionally reliable due to the use of |
|||||||||
P 400 LDA |
P 300 LDA |
|
|
|
|
|
|
high-quality plastic |
|
|
|
||||||||
r = |
|
r = |
|
IP 65 |
|
|
+ 50 °C |
|
• optimum illumination due to prismatic coloured lens |
|
|||||||||
9 m |
|
7 m |
|
|
|
|
- 25 °C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Range as |
Range as |
Protection |
|
Operating |
|
|
|
|
|
|
|
|
|
|
|||||
per EN 54 |
per EN 54 |
system |
|
temperature |
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Electrical data |
|
|
|
|
|
|
|
P 400 LDA |
P 300 LDA |
||||||||||
Rated voltage |
|
|
|
|
|
|
115 V AC |
|
|
230 V AC |
|
12 / 24 V DC |
|
115 / 230 V AC |
|
12 / 24 V DC |
|||
Operating range |
|
|
|
100 V – 130 V |
|
207 V – 253 V |
|
10 V – 50 V |
|
90 V – 253 V |
|
10 V – 50 V |
|||||||
Nominal current consumption |
|
140 mA |
|
|
70 mA |
|
400 mA @ 24 V DC |
|
90 mA @ 115 V AC |
|
130 mA @ 24 V DC |
||||||||
|
|
|
|
|
50 mA @ 230 V AC |
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Mechanical data |
|
|
|
|
|
|
P 400 LDA |
|
|
|
|
P 300 LDA |
|||||||
Operating mode |
|
|
|
|
|
|
|
LED multifunction light with 9 internally selectable operating modes |
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Light source |
|
|
|
|
|
|
|
|
|
|
|
|
high output LED array |
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Light intensity (DIN 5037) |
clear lens |
|
|
|
|
|
30 cd |
|
|
|
|
20 cd |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Lens colours |
|
|
|
|
|
|
|
|
|
|
|
yellow, amber, red, green, blue |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Lens type |
|
|
|
|
|
|
|
|
|
|
|
|
prismatic |
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Operating temperature |
|
|
|
|
|
|
|
|
|
- 25 °C ... + 50 °C |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Relative humidity |
|
|
|
|
|
|
|
|
|
90% @ + 20 °C |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Protection system according to EN 60529 |
|
|
|
|
|
|
|
IP 65 |
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Service life of light source |
|
|
|
|
|
|
|
|
|
> 50.000 hrs |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Material |
|
|
|
|
|
|
|
|
|
|
|
polycarbonate (PC), UL 94 VO f1 |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Design |
|
|
|
|
|
|
|
|
|
|
bayonet with anti-tamper locking screw |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
Mounting |
|
|
|
|
|
|
|
|
|
surface mounting (wall bracket and tubular stand available as accessories) |
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
Cable entry |
|
|
|
|
|
|
|
|
1 x 5-7 mm push through grommet (bottom side); 2 x M20 cable entries sideways |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Connecting terminals |
|
|
|
|
|
|
|
|
screw terminals 1.5 mm2 |
|
|
|
|||||||
Weight |
|
|
|
AC version |
|
|
|
|
|
595 g |
|
|
|
|
285 g |
|
|||
|
|
|
DC version |
|
|
|
|
|
845 g |
|
|
|
|
285 g |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operating modes Stage 1: internally selectable, stages 2 & 3 externally controllable (DC lights only)
|
P 400 LDA |
|
P 300 LDA |
|
|
Mode |
Stage 1 |
Stage 2 (DC only) |
Stage 3 (DC only) |
Stage 1 |
Stage 2 (DC only) |
1 |
all LEDs on |
alternating flash 2 Hz |
double flash 2 Hz |
all LEDs on |
alternating flash 2 Hz |
2 |
rotation: slow “on” |
alternating flash 2 Hz |
all LEDs on |
rotation: slow “on” |
alternating flash 2 Hz |
3 |
single flash 2Hz |
rotation: fast “off” |
all LEDs on |
single flash 2 Hz |
rotation: fast “off” |
4 |
rotation: fast “on” |
single flash 2 Hz |
all LEDs on |
rotation: fast “on” |
single flash 2 Hz |
5 |
rotation: slow “off” |
double flash 1 Hz |
all LEDs on |
rotation: slow “off” |
double flash 1 Hz |
6 |
double flash 1 Hz |
rotation: fast “off” |
all LEDs on |
double flash 1 Hz |
rotation: fast “off” |
7 |
rotation: fast “off” |
double flash 2 Hz |
all LEDs on |
rotation: fast “off” |
double flash 2 Hz |
8 |
double flash 2 Hz |
alternating flash 2 Hz |
double flash 2 Hz |
alternating flash 2 Hz |
all LEDs on |
9 |
alternating flash 2 Hz |
rotation: fast “off” |
alternating flash 2 Hz |
rotation: fast “off” |
all LEDs on |
|
|
|
|
|
|
|
|
|
|
ELECTRO-TECHNOLOGY FOR INDUSTRY |
|
|
|
|
|
|
|
Dimensions |
|
|
|||
|
|
|
P 400 LDA |
P 300 LDA |
|
|
|
|
|
|
|
|
cable entry |
<![if ! IE]> <![endif]>150 |
|
<![if ! IE]> <![endif]>220 |
2 x M20 |
cable entry |
|
|
M20 |
<![endif]>37
<![if ! IE]> <![endif]>58 |
<![if ! IE]> <![endif]>20 |
<![endif]>20
Ø 100
Ø 140
cable entry Ø 5-7 mm
25°
120°
mounting holes 3 x Ø 5.4 mm
<![if ! IE]><![endif]>Ø 110
47
85°
120°
27
cable entry Ø 5-7 mm
45°
mounting holes 2 x Ø 5.4 mm
<![if ! IE]><![endif]>27.5 55
60°
Ordering details
Article numbers |
|
|
|
|
P 400 LDA |
|
|
|
|
P 300 LDA |
|
||||||
Lens colour |
Rated voltage |
|
230 V AC |
|
115 V AC |
|
12 / 24 V DC |
|
115 / 230 V AC |
|
12 / 24 V DC |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
yellow |
|
|
213 48 10 3 000 |
213 48 15 3 000 |
|
213 48 90 3 000 |
|
213 38 17 3 000 |
|
213 38 90 3 000 |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
amber |
|
|
213 48 10 4 000 |
213 48 15 4 000 |
|
213 48 90 4 000 |
|
213 38 17 4 000 |
|
213 38 90 4 000 |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
red |
|
|
213 48 10 5 000 |
213 48 16 5 000 |
|
213 48 90 5 000 |
|
213 38 17 5 000 |
|
213 38 90 5 000 |
|
||||||
Article numbers for other colours on request |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Options / accessories |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
for |
|
for |
|
|
for |
|
|
for |
|
|
only in |
See pages 122/123 for |
|
|||
|
|
Tubular |
Tubular |
|
|
|
|||||||||||
Wall |
P 400 |
Wall |
P 300 |
|
P 400 |
|
P 300 |
|
Wall |
combination |
further information |
|
|
||||
bracket |
|
bracket |
|
|
stand |
|
|
stand |
|
|
holder |
with tubular |
|
|
|
|
|
|
|
|
145 mm |
|
|
140 mm |
|
|
stand |
|
|
|
|
||||
Article number: |
Article number: |
Article number: |
|
Article number: |
Article number: |
|
|
|
|
||||||||
213 94 00 0 000 |
213 92 00 0 000 |
213 95 00 0 000 |
213 93 00 0 000 |
282 50 20 0 000 |
|
|
|
|
|
Conformity to standards
The visual characteristics of LED lights conform to the European standard DIN EN 842: ‘Machine safety – visual alarm signals’.
Requirements contained in the DIN EN 981 standard: ‘Machine safety – system of acoustic and visual alarm and information signals’, can be fulfilled. The colours ‘red’ for the emergency signal and ‘yellow’ for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199:
‘Coding of display devices and control elements using colours and supplementary means’.
References to visual alarm devices can be found in the following standards:
EN 60825-1 |
Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 |
DIN EN 54 |
Fire alarm systems |
DIN 54113-2 |
Radiation protection regulations for the technical operation of X-ray equipment up to 500 kV |