Perlick ST72 Operators Manual

Installation
& Operation Manual
Slant Top Bottle Cooler
ST Series
C
US
Form No. Z2322 Rev. 04.25.2017
Slant Top Bottle Coolers Installation & Operation Manual
JOB
AREA
ITEM NO.
MODEL NO.
ST48 SERIES
ST48LT SERIES
ST72 SERIES
ST72LT SERIES
ST72 Series shown
C
US
TABLE OF CONTENTS
Installing
- Uncrating and Inspection...................................................................................................................... 2
- Plumbing .............................................................................................................................................. 3
- Electrical ............................................................................................................................................... 3
- Adjusting Partitions ............................................................................................................................... 3
- Installing Casters and Legs .................................................................................................................. 3
- Placing the Cabinet .............................................................................................................................. 3
- Sealing to the Floor .............................................................................................................................. 4
Temperature Control ................................................................................................................................ 4
Cleaning the Cabinet/Doors .................................................................................................................... 4
Cleaning the Condenser .......................................................................................................................... 4
Stainless Steel Care ................................................................................................................................ 4
Wiring Diagrams ................................................................................................................................... 5/6
Replacement Parts ............................................................................................................................... 7/8
GENERAL INFORMATION
Introduction
This manual has been prepared to assist you in the installation of your Bottle Cooler and to acquaint you with its operation and maintenance.
We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction. If service is required, call Perlick at 1-800-777-7267 or your dealer who can provide
you with a list of qualied service agents. For
your own protection, never return merchandise for credit without our approval.
We thank you for selecting a Perlick product and assure you of our continuing interest in your satisfaction.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Printed in USA 2
Warranty
To register your product, visit our web site at www.perlick.com. Click on “Commercial”, then “Service”. Click on the link “Warranty Registration Form”. You must complete and submit this form or the installation date will revert back to the ship date.
Please record the purchase date and the dealer’s name, address and telephone number below.
Model Number: ________________________ Serial Number: _________________________ Purchase Date: _______________________ Dealer Name & Address __________________ ______________________________________ ______________________________________ Phone Number__________________________
Slant Top Bottle Coolers Installation & Operation Manual
CAUTION
CAUTION
PREPARING THE CABINET - FLAT TOP BOTTLE COOLERS
Uncrating and Inspection
Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If
damage is discovered, le your claim immediately
with the transport company. Perlick is not responsible for damage in transit.
Plumbing
No plumbing connections are required. Condensate from the cooling coil automatically evaporated through a condensate pan located in the condensing unit section.
Electrical
The cabinet must be connected to a separately
fused power source (see Electrical Specication
Plate) and grounded in accordance with National and Local electrical codes.
Do not attempt to operate the equipment on any
other power source than that listed on the
Electrical Specication Plate.
Placing the Cabinet
To assure maximum performance, fresh air must be allowed to circulate through the machinery compartment. It is important to allow at least two inched of clearance at the back or left end of the cabinet. Do not place anything in front of
the cabinet that would obstruct air ow at these
grilles. Do not place the unit in an unventilated small room.
Removing the factory
installed back clearance
spacers without providing proper left side grill
clearance for compressor air ow will void the warranty.
Cabinet should be leveled.
For sanitation purposed, it may be necessary
to seal the base of the cabinet to the oor. This
can be accomplished by laying a bead of silicone sealant along the base of the cabinet as shown
by the gure below (gure 1).
Adjustable Partitions & Shelving
Perlick Bottle Coolers may be provided with adjustable partitions and shelving which will accommodate various bottle sizes.
■ Remove bottles and cans from their cases before placing in cooler to ensure proper
air ow.
Installing Casters or Legs (optional)
Attach casters or legs to the cabinet bottom in holes provided. Use the supplied 1/4” - 20 hex head self-tapping machine screws. If unit is tipped on its back for an extended period of time, wait 24 hours after unit is uprighted to plug the unit in. Please refer to the instruction sheet included with the leg and caster kit for additional installation details.
Cabinet
Bead Silicon Sealer (RTV)
Floor
Figure 1. Sealing Cabinet to Floor
Printed in USA 3
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Slant Top Bottle Coolers Installation & Operation Manual
HOW TO OPERATE - SLANT TOP BOTTLE COOLERS
Temperature Control
An adjustable temperature control is located inside the Slant Top Bottle Cooler on the evaporator fan panel assembly. It is factory set at
approximately 38˚F for standard refrigeration and approximately 30˚F for low temperature models.
Make adjustments as detailed below to attain the desired temperature.
NOTE: On models ST48 and ST72, temperature settings 34˚F will not allow adequate time to
defrost the evaporator coil during the off cycle.
NOTE: On models ST48LT and ST72LT, temperature settings below 30˚F may freeze and
damage some products.
Colder Temperatures: Turn the adjusting screw clockwise (to the right).
Warmer Temperatures: Turn the adjusting screw counterclockwise (to the left).
Temperature Control “OFF”: Turn the adjusting screw completely counterclockwise
to the “O” position until a “click” is noted.
The condenser fan motor turns off and on with compressor. The evaporator fan motor runs continuously.
Cleaning the Condenser
■ The condenser (located behind the from grille) should be inspected every 30 days, and cleaned, if necessary. Failure to keep the condenser clean will cause a loss in condensing unit efciency, or compressor failure.
Avoiding Stainless Steel Corrosion
Corrosion can be prevented by following product cautions, cleaning instructions and avoiding use of certain chemicals or objects which will cause stainless steel corrosion.
STAINLESS STEEL ENEMY
■ Steel wool or steel scouring pads
■ Cherry/Orange/Olive juice
■ Chlorine Bleach
■ Sharp Objects
Cleaning the Doors
■ Doors should be periodically removed from the cabinet and inspected for a buildup of foreign materials, such as syrups, beer, etc. Buildups on the underside of the doors, along with the door tracks on which they ride, will cause them to bind, and therefore, not function as designed. If dirty, these surfaces should be cleaned with a mild detergent and water and then coated with NSF approved silicone lubricating material. Aerosol silicone sprays can be obtained locally at most hardware or automotive stores.
To remove doors:
■ Grasp the sides of each door and gently lift up to frees them from the door track. Use the reverse procedure to reinstall the doors.
Cleaning the Cabinets
■ Use a damp cloth with a mild detergent and water to clean the inside and outside of the cabinet. Dry thoroughly. Do not allow cleaning agents or large amounts of water to go down the drain. Use an acceptable stainless steel polish to clean all stainless steel surfaces. Never use steel wool or scouring pads to clean stainless steel.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Printed in USA 4
Slant Top Bottle Coolers Installation & Operation Manual
WIRING DIAGRAM - SLANT TOP BOTTLE COOLERS ST48 AND ST72
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Printed in USA 5
Slant Top Bottle Coolers Installation & Operation Manual
WIRING DIAGRAM - LOW-TEMP BOTTLE COOLERS
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Printed in USA 6
Slant Top Bottle Coolers Installation & Operation Manual
REPLACEMENT PARTS - FLAT TOP BOTTLE COOLERS
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Printed in USA 7
Slant Top Bottle Coolers Installation & Operation Manual
REPLACEMENT PARTS - SLANT TOP BOTTLE COOLERS
MODEL NOS. ST48 ST72 ST48LT ST72LT
Item Description Part Numbers
1 Complete condensing unit C22647 C22646 C22647 C22646
2 Compressor Call Factory Call Factory Call Factory Call Factory
Overload/Relay/Capacitor Kit US-PB10HBX1 US-PB12HBX1 US-PB10HBX1 US-PB12HBX1
3 Condensate pan 64626-1 64626-1 64626-1 64626-1
4 Evaporator fan motor(s) C15239A C15239A C15239A C15239A
5 Evaporator fan motor bracket 60988-1 60988-1 60988-1 60988-1
6 Evaporator fan motor blade 57699 57699 57699 57699
7 Evaporator fan guard 65667 65667 65557 65557
8 Evaporator n coil C17511-1EP C17511-2EP C17511-1EP C17511-2EP
9 Temperature control 61283 61283 65634 65634
10 Bottle opener (optional) C6713-1 C6713-1 C6713-1 C6713-1
11 Bottle cap receiver (optional) C17332SS C17332SS C17332SS C17332SS
12 Front grille 65662-1A 65662-1A 65662-1A 65662-1A
13 Rear grille 65662-3 65662-3 65662-3 65662-3
14 Top assembly RT-SL2 RT-SL2 RT-SL2 RT-SL2
15 Top wiper gasket 63671-48 63671-72 63671-48 63671-72
16 Door assembly RD-SL2 RD-SL2 RD-SL2 RD-SL2
17 Lock 67226 67226 67226 67226
18 Vertical partition 66927-2 66927-2 66927-2 66927-2
19 Roller basket 66442-1 66442-1 66442-1 66442-1
20 Bottom oor rack (narrow) 64815-1 64815-1 64815-1 64815-1
Wide shelf 64811-1 64811-1 64811-1 64811-1
21
22 Bottom oor rack (wide) 64814-1 64814-1 64814-1 64814-1
23 Narrow shelf 64809-1 64809-1 64809-1 64809-1
24 Shelf bracket 65653-48 65653-72 65653-48 65653-72
25 Door handle 63931 63931 63931 63931
26 Light Bulb (optional) C15046 C15046 C15046 C15046
27 Light socket (optional) 63484 63484 63484 63484
28 Evaporator drain pan 65526-1SL 65526-2SL 65526-1SL 65526-2SL
29 Cover, horizontal 65656-48 65656-72 65656-48 65656-72
30 Cover, vertical 65659-3 65659-3 65659-3 65659-3
31 Track mounting bracket, upper 66870-48 66870-72 66870-48 66870-72
32 Door track, lower 67153-48 67153-72 67153-48 67153-72
33 Track mounting bracket, lower 66871-48 66871-72 66871-48 66871-72
34 Door track, sides 67153-1 67153-1 67153-1 67153-1
35 Evaporator n guard 69056-1 69056-2 69056-1 69056-2
36 Door track, upper 67154-48 67154-72 67154-48 67154-72
37 Door bumper 67236 67236 67236 67236
38 Evaporator bafe 66488-1 66488-2 66488-1 66488-2
39 Cover, bottom track bracket 66872-48 66872-72 66872-48 66872-72
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Printed in USA 8
Slant Top Bottle Coolers Installation & Operation Manual
8300 West Good Hope Road • Milwaukee, WI 53223 •
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
Toll Free 800.558.5592 • Fax 414.353.7069 • www.perlick.com
Printed in USA 9
Loading...