Congratulations on your purchase of a Perlick
commercial back bar product. This manual has
been prepared to assist you in the installation of
your cabinet and to acquaint you with its operation
and maintenance.
We dedicate considerable time to ensure that our
products provide the highest level of customer
satisfaction. If service is required, your dealer
can provide you with a list of qualied service
agents. For your own protection, never return
merchandise for credit without our approval.
We thank you for selecting a Perlick product
and assure you of our continuing interest in your
satisfaction.
safeTy
PLEASE READ all instructions completely
before attempting to install or operate the unit.
Take particular note of the DANGER, WARNING
an CAUTION information in the manual. The
information is important for the safe and efcient
installation, operation and care of your Perlick unit.
DANGER
death if precautions are not followed.
Indicates a hazard that WILL
result in serious injury or
Warranty
To register your product, visit our web site at
www.perlick.com. Click on “Commercial”, then
“Service”. Click on the link “Warranty Registration
Form”. You must complete and submit this form
or the installation date will revert back to the ship
date.
Please record the purchase date and the dealer’s
name, address and telephone number below.
Model Number: ________________________
Serial Number: _________________________
Purchase Date: _______________________
Dealer Name & Address
______________________________________
______________________________________
______________________________________
Phone Number__________________________
WARNING
death if precautions are not followed.
CAUTION
damage may occur if precautions are not
followed.
Indicates a hazard MAY
cause serious injury or
Indicates a hazard where
minor injury or product
IMPORTANT!
Read and understand all information in this manual before attempting the installation.
All plumbing and electrical work must be performed by a qualied technician and
conform to all applicable state and local codes.
Printed in USA 2 0213
Models SDB/SDP Installation & Operation Manual
PrIor To InsTallaTIon
Uncrating and Inspection
Remove all crating material. Carefully inspect
cabinet for hidden damage. If damag e is
discovered, le your claim immediately with the
transport company. Perlick is not responsible for
damage in transit.
CAUTION
Cutting may result in damage to the exterior
of the cabinet. Failure to follow this procedure
may damage th e compressor an d void
warranty.
1. Uncrate the unit on at, level surface. Remove
the cardboard sleeve by removing the banding
securing the sleeve to the shipping base.
Carefully lift the cardboard sleeve up over the
top of the unit.
2. Carefully lift unit off the base and onto a hand
truck or dolly. Make sure unit is balanced
on transporting device using soft, exible
strapping. Protect unit surfaces with cloth
material where strapping contacts unit.
CAUTION
or damage to the unit could occur.
WARNING
minimum required to lift the unit. Larger units
may require additional personnel.
3. Before moving unit, secure door(s) to unit with
tape to prevent from opening.
4. Carefully move unit to installation site and
place in front of opening.
CAUTION
appropriate material to avoid damage from
moving the unit.
Do not cu t ca rdbo ard
sleeve covering the unit.
Do not lift unit by drawer,
shelving or door handles
To pr ev en t p er so n a l
i n j u r y, t w o pe o p l e
Finished ooring should
b e p r o t e c t e d w i t h
Plumbing
CAUTION
threads could occur.
The condensate drain tube (furnished) must be
connected to the unit. One end is attached to the
barbed elbow on the evaporator condensate pan;
the other end is inserted through the evaporator
drain hole and exits the bottom of the cabinet.
The drain hole is located in the cabinet oor pan,
behind the vertical door mullion.
Do not over-tighten drain
fitting or damage to the
The drain tube must be placed over a oor drain
or into a condensate management system such
as a “Condensate Evapaway’ pan and heater.
Electrical
The cabinet must be connected to a separately
fused power source (see Electrical Specication
Plate afxed to unit) in accordance with National
and Local electrical codes.
Self-contained Perlick units come equipped with
a NEMA 5-15P 90° plug with an 8’ cord extending
beyond the rear of the cabinet. The electrical
outlet must be ush with, or recessed into, the
wall surface.
NOTE: Never use an extension cord to extend the
power cord to the electrical receptacle.
CAUTION
upright and allow minimum of 24 hours before
connecting power. Failure to follow this
procedure may damage the compressor and
void the warranty.
CAUTION
other power source than that listed on the
Electrical Specication Plate attached to the
unit.
DANGER
required. Appliances furnished with a 3-prong
(grounding) polarized plug are equipped for
your protection against possible shock
hazards.
• Never remove the round grounding prong
from the plug.
• Never use a 2-prong adapter.
• Never use extension cord to connect
power to the unit.
• If a 2-prong receptacle is encountered, or
a longer power cord is required, contact
a qualied electrician to have it replaced
in accordance with applicable electrical
codes.
DANGER
result in possible death or serious injury, re,
or loss of property.
If unit has been laid on its
back or sides, place unit
Do not attempt to operate
the equipm ent on any
ELECTROCUTION HAZARD!
Electric a l groundin g is
Failure to comply with these
electrical guidelines may
Printed in USA 3 0213
Models SDB/SDP Installation & Operation Manual
InsTallaTIon
General Information
• For units equipped with a power cord, the
cord and plug may be aligned with a recess in
the back panel to allow the unit to be pushed
closer to the wall. For correct alignment, the
wall outlet must be located 4” - 10” above the
oor.
• Floor must be level in area of installation.
Preparing the Space
CAUTION
surrounding nished oor. Protect a nished
oor with plywood, cardboard or some other
suitable material before moving the unit into
place. Failure to do this may result in damage
to the oor.
NOTE: If unit has been laid on its back or sides,
place unit upright and allow minimum of 24 hours
before connecting to a power source. Failure to
follow this procedure may damage the compressor
and void warranty.
Make sure the oor under
the unit is level with the
Installing the Unit
CAUTION
upright and allow minimum of 24 hours before
connecting power.
1. With power applied to the unit, check that
the lighting and cooling functions operate
properly, then turn off power to the wall outlet
and/or circuit breaker.
2. Position the cabinet into place using rollers
when necessary.
NOTE: Proper air ow around the condensing unit
is necessary for efcient operation. Never obstruct
the air ow in and out of the condensing unit.
3. When cabinet is in place, check installation
with carpenter’s level. When the unit is level
front-to-back and side-to-side, accumulated
water will drain out of cabinet to evaporator
drain.
4. Turn on power to the outlet and/or circuit
breaker.
If unit has been laid on its
back or sides, place unit
1. Make sure the space opening is correctly
sized for the unit. See Dimension drawings at
the back of this manual for correct dimensions.
NOTE: For a cabinet door to open properly, the
door must open a minimum of 90°. Use a minimum
3” ller in corner installations to assure a 90°
opening. Allow 24” clearance in front of the unit
for full door swing and shelf/drawer pull-out.
2. Check that the following are level and square:
• Front and interior opening
• Installation opening and oor surface
NOTE: The oor under the unit must be at the
same level as the surrounding nished oor.
Casters or Legs
Refer to the instructions included with the Casters
or Legs Kit.
Electric Condensate Evapaway
(Optional)
For installation in areas of high humidity, a 115volt electric condensate pan can be installed
underneath the cabinet to collect and evaporate
the condensate from the cabinet evaporator. A 6’
3-prong plug is included. A separate circuit should
be provided for the heater. The kit can be used
only on cabinets equipped with 4” minimum legs;
it cannot be used on units equipped with platform
or base plate kits. Follow instructions supplied
with the kit.
Base Plate Installation (Optional)
Once the unit is secured in place, install the base
plate brackets to the cabinet bottom in the holes
provided. Attach base plate to brackets. Refer
to the installation instructions included with the
Base Plate Kit.
Printed in USA 4 0213
Models SDB/SDP Installation & Operation Manual
or
Sealing Cabinet to Floor
For units without casters or legs, it may be
necessary to seal the base of the cabinet to
the oor. This can be accomplished by laying a
bead of silicone sealant between the base of the
cabinet and the oor (Figure 1).
oPeraTIon
Refrigeration and Temperature Control
The cabinet is equipped with a heavy-duty
refrigeration system designed to automatically
maintain a storage temperature of approximately
38° F.
Allow a minimum of 24 hours for ambient
temperature product to reach storage temperature.
Draft beer should be stored at a temperature
between 32° – 38° F. The most common cause
of dispensing problems is improper temperature;
beer will foam at warmer temperatures.
Beer will freeze at temperatures lower than
30° F. When beer freezes, the alcohol in the beer
may separate and cause the beer to be cloudy
with an “off” taste.
The following chart shows how temperature
affects beer:
Cabinet
Bead Silicon
Sealer (RTV)
Floor
Figure 1. Sealing Cabinet to Floor
• Room temperature where installed
• Number of times the door is opened and
closed
• Length of time door is left open
• Style of door installed
• Door gasket seal and condition
• Amount of time the internal light is illuminated
• Installation in direct sunlight or near a heat
source
Interior Light
The unit is equipped with an interior LED light in
the upper front of the unit just inside the door or
drawer. The light illuminates when the manual
rocker light switch is turned on. The rocker light
switch is located behind the LED light on the inside
of the frame on either the right or left side (same
side as the compressor).
Digital Temperature Control
C
F
Checking Product Temperature
1. To accurately check the temperature of product
stored in the refrigerated compartment, insert
an accurate thermometer into a plastic
unbreakable bottle, partially lled with water.
Tighten bottle cap securely.
2. Place the bottle in the desired area for 24
hours. Refrain from opening the unit during
the testing period. After 24 hours, check
the temperature of the water. Adjust the
temperature accordingly using the procedures
on this page.
The following factors affect the internal temperature
of the unit:
• Temperature setting
Printed in USA 5 0213
SE T
Figure 2. Digital Temperature Controller
To change the Setpoint:
1. Press the SET button for more than 2 seconds.
2. The value of the setpoint will be displayed and
the “C” or “F” LED starts blinking.
3. To ch ang e t he S et val ue , pr es s th e
button within 10 seconds.
4. To memorize the new setpoint value, press
the SET key again, or wait 10 seconds.
Models SDB/SDP Installation & Operation Manual
adjusTmenTs
DANGER
perform maintenance on
the unit until the main electrical power to the
unit has been disconnected!
Shelving Adjustment
Never attempt to repair or
CAUTION
1. Open the door. Tilt the shelf and remove it
from the unit
2. Reposition each bracket separately. Grasp the
middle of the bracket, pull the front end up and
out, then forward to remove it. See Figure 3.
3. Place brackets at desired location and reinstall
shelf(s).
Completely empty shelf or
drawer before removing.
5. Plug new LED into harness and secure to
housing using screws removed in step 2.
6. Snap LED cover into place.
Sliding Doors
Removing / Installing
1. To remove the sliding door, simply grasp the
door on each side and lift up off the bottom
track, then tilt outwards and pull down to
remove from upper track.
2. To reinstall sliding door, place door in upper
track, making sure to engage the bracket
(Figure 5), lift door up into the track and place
into the bottom track.
Adjusting Door Spring Tension
A tension spring is located in the upper track of
each door. To increase or decrease spring tension,
remove the Phillips screw and position the bracket
in one of three detentes and reinstall screw. The
detente farthest to the left provides the least
amount of tension.
Figure 3. Shelf Bracket
LED Light Replacement
Unplug LED Light Strip
LED Light Strip
Lens Cover
#6-32 x 3/8”
machine screw (Qty. 2)
Figure 4. Interior LED Light
1. Open the door.
2. Using a at blade screwdriver, carefully pry
off the lens cover.
3. Remove the two screws securing LED light to
housing.
4. Unplug the LED from the wiring harness.
NOTE: Units are shipped from the factory with
springs set at the weakest setting.
Make sure door engages bracket
Figure 5. Removing/Installing Sliding Door
Sliding Door Lock
Each set of sliding doors is equipped with a keyed
lock located on the bottom of the right side door. To
lock the doors, place the lock lever in the DOWN
position and lock with the key. Unlock with the key
and place lever in the UP position to open.
Printed in USA 6 0213