Perlick SDBR48 User Manual

Installation
& Operation Manual
Commercial Back Bar
Sliding Door
SDB & SDP Series
Model SDBR48 Shown
Form No. 2722013
Models SDB/SDP Installation & Operation Manual
Table of ConTenTs
General Information ................................................................................................................................. 2
Safety ......................................................................................................................................................2
Prior To Installation .................................................................................................................................. 3
Installation ...............................................................................................................................................4
Operation ................................................................................................................................................. 5
Adjustments ............................................................................................................................................. 6
Maintenance ............................................................................................................................................ 7
Troubleshooting ....................................................................................................................................... 9
Dimensions ............................................................................................................................................ 11
Wiring Diagrams .................................................................................................................................... 15
Warranty ................................................................................................................................................ 19
General InformaTIon
Introduction
Congratulations on your purchase of a Perlick commercial back bar product. This manual has been prepared to assist you in the installation of your cabinet and to acquaint you with its operation and maintenance.
We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction. If service is required, your dealer can provide you with a list of qualied service agents. For your own protection, never return merchandise for credit without our approval.
We thank you for selecting a Perlick product and assure you of our continuing interest in your satisfaction.
safeTy
PLEASE READ all instructions completely before attempting to install or operate the unit. Take particular note of the DANGER, WARNING an CAUTION information in the manual. The information is important for the safe and efcient installation, operation and care of your Perlick unit.
DANGER
death if precautions are not followed.
Indicates a hazard that WILL result in serious injury or
Warranty
To register your product, visit our web site at www.perlick.com. Click on “Commercial”, then “Service”. Click on the link “Warranty Registration Form”. You must complete and submit this form or the installation date will revert back to the ship date.
Please record the purchase date and the dealer’s name, address and telephone number below.
Model Number: ________________________ Serial Number: _________________________ Purchase Date: _______________________ Dealer Name & Address ______________________________________ ______________________________________ ______________________________________ Phone Number__________________________
WARNING
death if precautions are not followed.
CAUTION
damage may occur if precautions are not followed.
Indicates a hazard MAY cause serious injury or
Indicates a hazard where minor injury or product
IMPORTANT!
Read and understand all information in this manual before attempting the installation.
All plumbing and electrical work must be performed by a qualied technician and
conform to all applicable state and local codes.
Models SDB/SDP Installation & Operation Manual
PrIor To InsTallaTIon
Uncrating and Inspection
Remove all crating material. Carefully inspect cabinet for hidden damage. If damag e is discovered, le your claim immediately with the transport company. Perlick is not responsible for damage in transit.
CAUTION
Cutting may result in damage to the exterior of the cabinet. Failure to follow this procedure may damage th e compressor an d void warranty.
1. Uncrate the unit on at, level surface. Remove the cardboard sleeve by removing the banding securing the sleeve to the shipping base. Carefully lift the cardboard sleeve up over the top of the unit.
2. Carefully lift unit off the base and onto a hand truck or dolly. Make sure unit is balanced on transporting device using soft, exible strapping. Protect unit surfaces with cloth material where strapping contacts unit.
CAUTION
or damage to the unit could occur.
WARNING
minimum required to lift the unit. Larger units may require additional personnel.
3. Before moving unit, secure door(s) to unit with tape to prevent from opening.
4. Carefully move unit to installation site and place in front of opening.
CAUTION
appropriate material to avoid damage from moving the unit.
Do not cu t ca rdbo ard
sleeve covering the unit.
Do not lift unit by drawer, shelving or door handles
To pr ev en t p er so n a l
i n j u r y, t w o pe o p l e
Finished ooring should b e p r o t e c t e d w i t h
Plumbing
CAUTION
threads could occur.
The condensate drain tube (furnished) must be connected to the unit. One end is attached to the barbed elbow on the evaporator condensate pan; the other end is inserted through the evaporator drain hole and exits the bottom of the cabinet. The drain hole is located in the cabinet oor pan, behind the vertical door mullion.
Do not over-tighten drain fitting or damage to the
The drain tube must be placed over a oor drain or into a condensate management system such as a “Condensate Evapaway’ pan and heater.
Electrical
The cabinet must be connected to a separately fused power source (see Electrical Specication Plate afxed to unit) in accordance with National and Local electrical codes.
Self-contained Perlick units come equipped with a NEMA 5-15P 90° plug with an 8’ cord extending beyond the rear of the cabinet. The electrical outlet must be ush with, or recessed into, the wall surface.
NOTE: Never use an extension cord to extend the power cord to the electrical receptacle.
CAUTION
upright and allow minimum of 24 hours before connecting power. Failure to follow this procedure may damage the compressor and void the warranty.
CAUTION
other power source than that listed on the Electrical Specication Plate attached to the unit.
DANGER
required. Appliances furnished with a 3-prong (grounding) polarized plug are equipped for your protection against possible shock hazards.
Never remove the round grounding prong from the plug.
Never use a 2-prong adapter.
Never use extension cord to connect power to the unit.
If a 2-prong receptacle is encountered, or a longer power cord is required, contact a qualied electrician to have it replaced in accordance with applicable electrical codes.
DANGER
result in possible death or serious injury, re, or loss of property.
If unit has been laid on its back or sides, place unit
Do not attempt to operate the equipm ent on any
ELECTROCUTION HAZARD! Electric a l groundin g is
Failure to comply with these electrical guidelines may
Models SDB/SDP Installation & Operation Manual
InsTallaTIon
General Information
For units equipped with a power cord, the cord and plug may be aligned with a recess in the back panel to allow the unit to be pushed closer to the wall. For correct alignment, the wall outlet must be located 4” - 10” above the oor.
Floor must be level in area of installation.
Preparing the Space
CAUTION
surrounding nished oor. Protect a nished oor with plywood, cardboard or some other suitable material before moving the unit into place. Failure to do this may result in damage to the oor.
NOTE: If unit has been laid on its back or sides, place unit upright and allow minimum of 24 hours before connecting to a power source. Failure to follow this procedure may damage the compressor and void warranty.
Make sure the oor under the unit is level with the
Installing the Unit
CAUTION
upright and allow minimum of 24 hours before connecting power.
1. With power applied to the unit, check that the lighting and cooling functions operate properly, then turn off power to the wall outlet and/or circuit breaker.
2. Position the cabinet into place using rollers when necessary.
NOTE: Proper air ow around the condensing unit is necessary for efcient operation. Never obstruct the air ow in and out of the condensing unit.
3. When cabinet is in place, check installation with carpenter’s level. When the unit is level front-to-back and side-to-side, accumulated water will drain out of cabinet to evaporator drain.
4. Turn on power to the outlet and/or circuit breaker.
If unit has been laid on its back or sides, place unit
1. Make sure the space opening is correctly sized for the unit. See Dimension drawings at the back of this manual for correct dimensions.
NOTE: For a cabinet door to open properly, the door must open a minimum of 90°. Use a minimum 3” ller in corner installations to assure a 90° opening. Allow 24” clearance in front of the unit for full door swing and shelf/drawer pull-out.
2. Check that the following are level and square:
Front and interior opening
Installation opening and oor surface
NOTE: The oor under the unit must be at the same level as the surrounding nished oor.
Casters or Legs
Refer to the instructions included with the Casters or Legs Kit.
Electric Condensate Evapaway (Optional)
For installation in areas of high humidity, a 115­volt electric condensate pan can be installed underneath the cabinet to collect and evaporate the condensate from the cabinet evaporator. A 6’ 3-prong plug is included. A separate circuit should be provided for the heater. The kit can be used only on cabinets equipped with 4” minimum legs; it cannot be used on units equipped with platform or base plate kits. Follow instructions supplied with the kit.
Base Plate Installation (Optional)
Once the unit is secured in place, install the base plate brackets to the cabinet bottom in the holes provided. Attach base plate to brackets. Refer to the installation instructions included with the Base Plate Kit.
Models SDB/SDP Installation & Operation Manual
or
Sealing Cabinet to Floor
For units without casters or legs, it may be necessary to seal the base of the cabinet to the oor. This can be accomplished by laying a bead of silicone sealant between the base of the cabinet and the oor (Figure 1).
oPeraTIon
Refrigeration and Temperature Control
The cabinet is equipped with a heavy-duty refrigeration system designed to automatically maintain a storage temperature of approximately 38° F.
Allow a minimum of 24 hours for ambient temperature product to reach storage temperature.
Draft beer should be stored at a temperature between 32° – 38° F. The most common cause of dispensing problems is improper temperature; beer will foam at warmer temperatures.
Beer will freeze at temperatures lower than 30° F. When beer freezes, the alcohol in the beer may separate and cause the beer to be cloudy with an “off” taste.
The following chart shows how temperature affects beer:
Cabinet
Bead Silicon Sealer (RTV)
Floor
Figure 1. Sealing Cabinet to Floor
Room temperature where installed
Number of times the door is opened and closed
Length of time door is left open
Style of door installed
Door gasket seal and condition
Amount of time the internal light is illuminated
Installation in direct sunlight or near a heat source
Interior Light
The unit is equipped with an interior LED light in the upper front of the unit just inside the door or drawer. The light illuminates when the manual rocker light switch is turned on. The rocker light switch is located behind the LED light on the inside of the frame on either the right or left side (same side as the compressor).
Digital Temperature Control
C F
Checking Product Temperature
1. To accurately check the temperature of product stored in the refrigerated compartment, insert an accurate thermometer into a plastic unbreakable bottle, partially lled with water. Tighten bottle cap securely.
2. Place the bottle in the desired area for 24 hours. Refrain from opening the unit during the testing period. After 24 hours, check the temperature of the water. Adjust the temperature accordingly using the procedures on this page.
The following factors affect the internal temperature of the unit:
Temperature setting
SE T
Figure 2. Digital Temperature Controller
To change the Setpoint:
1. Press the SET button for more than 2 seconds.
2. The value of the setpoint will be displayed and the “C” or “F” LED starts blinking.
3. To ch ang e t he S et val ue , pr es s th e
button within 10 seconds.
4. To memorize the new setpoint value, press the SET key again, or wait 10 seconds.
Models SDB/SDP Installation & Operation Manual
adjusTmenTs
DANGER
perform maintenance on the unit until the main electrical power to the unit has been disconnected!
Shelving Adjustment
Never attempt to repair or
CAUTION
1. Open the door. Tilt the shelf and remove it
from the unit
2. Reposition each bracket separately. Grasp the
middle of the bracket, pull the front end up and out, then forward to remove it. See Figure 3.
3. Place brackets at desired location and reinstall
shelf(s).
Completely empty shelf or drawer before removing.
5. Plug new LED into harness and secure to housing using screws removed in step 2.
6. Snap LED cover into place.
Sliding Doors
Removing / Installing
1. To remove the sliding door, simply grasp the door on each side and lift up off the bottom track, then tilt outwards and pull down to remove from upper track.
2. To reinstall sliding door, place door in upper track, making sure to engage the bracket (Figure 5), lift door up into the track and place into the bottom track.
Adjusting Door Spring Tension
A tension spring is located in the upper track of each door. To increase or decrease spring tension, remove the Phillips screw and position the bracket in one of three detentes and reinstall screw. The detente farthest to the left provides the least amount of tension.
Figure 3. Shelf Bracket
LED Light Replacement
Unplug LED Light Strip
LED Light Strip
Lens Cover
#6-32 x 3/8” machine screw (Qty. 2)
Figure 4. Interior LED Light
1. Open the door.
2. Using a at blade screwdriver, carefully pry off the lens cover.
3. Remove the two screws securing LED light to housing.
4. Unplug the LED from the wiring harness.
NOTE: Units are shipped from the factory with springs set at the weakest setting.
Make sure door engages bracket
Figure 5. Removing/Installing Sliding Door
Sliding Door Lock
Each set of sliding doors is equipped with a keyed lock located on the bottom of the right side door. To lock the doors, place the lock lever in the DOWN position and lock with the key. Unlock with the key and place lever in the UP position to open.
Loading...
+ 14 hidden pages