INSTALLATION AND OPERATION INSTRUCTIONS
ARCTICPOUR ADVANCED REFRIGERATION TECHNOLOGY
Table of Contents
Dimensional Drawings ............................................... 2
Product Description ................................................... 5
Installation ................................................................. 5
Important Safety Warnings .................................... 5
Installing the System ............................................. 5
All Models ......................................................... 6
Connecting to a Trunk Housing ............................. 6
Connecting Trunk Housing to Dispensing Head .... 6
System Pak Start-Up ................................................. 6
Digital Temperature Controller ................................... 7
Preventative Maintenance ......................................... 9
Replacement Parts .................................................... 9
Wiring Diagrams ...................................................... 11
IMPORTANT INFORMATION
To register your product, visit our web site at www.
perlick.com. Click on Commercial, then Service.
You will see the link to Warranty Registration Form.
You must complete and submit this form or the
installation date will revert back to the ship date.
Permanently mount the enclosed Warning/Safety
Instruction label in a visible location near the CO2
regulator.
MODELS
RD060, RD120,
RD060-O, RD120-O
GB1, GB2, GB3, GB4
Refrigeration Deck
This manual has been prepared to assist you in the
installation of your Century Remote Beer System and
to acquaint you with its operation and maintenance.
We dedicate considerable time to ensure that our
products provide the highest level of customer
satisfaction. If service is required, your dealer can
provide you with a list of qualified service agents. For
your own protection, never return merchandise for
credit without our approval.
We thank you for selecting a Perlick product and assure
you of our continuing interest in your satisfaction .
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414.353.7060 • Fax 414.353.7069
Toll Free 800.558.5592 • E-Mail perlick@perlick.com • www.perlick.com
Glycol Bath
Form No. Z2339
Rev. 06.10.2015
ARCTICPOUR
Operation/Installation Manual
Air-Cooled Refrigeration Deck
Permanently Connected Cord Connected
MODEL NOS. RD060 RD060-O RD120 RD120-O RD060-C
DIMENSIONS:
EXTERIOR (mm)
ELECTRICAL Voltage 120 V 120 V 208/230 V 208/230 V 120 V
COMPRESSOR 3/4 HP 3/4 HP 1.5 HP 1.5 HP 3/4 HP
EVAPORATOR RATING
@ 20°F (BTUH)
HEAT REJECTION (MAX) 8100 8100 16800 16800 8100
REFRIGERANT R-134a R-134a R-134a R-134a R-134a
SHIPPING WEIGHT LBS (kg) 120 (54) 120 (54) 140 (64) 140 (64) 120 (54)
CABINET Stainless Steel
REFRIGERATION Constant Pressure Expansion Valve, Condensing Unit with Service Valves
REFRIGERANT CHARGE (grams) 9.5 oz/269 g 9.5 oz/269 g 16 oz/453 g 16 oz/453 g 9.5 oz/269 g
Length 31-1/2” (800) 35-15/16” (913) 34-3/8” (873) 38-15/16” (989) 31-1/2” (775)
Width 17-3/8” (441) 28-1/4” (718) 21-3/4” (552) 33-3/8” (848) 17-3/8” (445)
Height 15-3/16” (386) 15-3/16” (387) 18-1/16” (459) 18-1/16” (459) 15-3/16” (386)
A minimum of 12” of clearance should be allowed around the entire unit for proper performance. Additional clearance should be considered for
above and in front of the unit for serviceability.
Frequency 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz
Phase 1 Ø 1 Ø 1 Ø 1 Ø 1 Ø
RLA 11.5 11.5 19.3 19.3 10.1
MCA 15.3 15.3 23.8 23.8 15.3
Max Fuse 20 20 40 40 20
Cord/Plug N/A N/A N/A N/A 14/3 NEMA 5-15P
6000 6000 12000 12000 6000
Glycol Bath
Permanently Connected Cord Connected
MODEL NOS. GB1 GB2 GB3 GB4 GB1-C GB2-C
DIMENSIONS:
EXTERIOR (mm)
ELECTRICAL Voltage 120 V 120 V 120 V 120 V 120 V 120 V
SHIPPING WEIGHT LBS (kg) 140 (64) 140 (64) 140 (64) 140 (64) 140 (64) 140 (64)
CIRCULATING PUMP #1 140 GPH / 130 PSIG
CIRCULATING PUMP #2, #3, #4 100 GPH / 130 PSIG
RESERVOIR CAPACITY 12 gal
GLYCOL CONCENTRATION 30% 30% 30% 30% 30% 30%
67451 Coolant Connector Parts Bag, Refrigeration Deck to Glycol Bath 61790+1 Rack, 37” X 19-3/4”, 3-Tiered
67451-1 Coolant Connector, Fabricated, Per Foot, Refrigeration Deck to Glycol Bath 61790+2 Rack, 37” X 19-3/4”, 4-Tiered
63299-1 Glycol Solution, 1 gallon 57782 Legs, Set of 4, 6” Nom
63335 Coolant Connector Kit (Glycol Bath to Trunk Housing) 68470-1 Wall Shelf, Large (RD120)
63335-1 Coolant Connector Kit (Glycol Bath to Trunk Housing) 68470-2 Wall Shelf, Small (RD060 or GB)
68455 Flashchill Connector Kit 68508 Rack, ArcticPOUR, Two Tier
C21499BSS Stand, 35” X 22” 68508+1 Rack, ArcticPOUR, +1 Extension
ACCESSORIES
61790 Rack, 37” X 19-3/4”, 2-Tiered 68508+2 Rack, ArcticPOUR, +2 Extension
Length “A” 24-3/4” (629) 24-3/4” (629) 24-3/4” (629) 24-3/4” (629) 24-3/4” (629) 24-3/4” (629)
Width “B” 19” (483) 23-11/16” (602) 23-11/16” (602) 23-11/16” (602) 19” (483) 23-11/16” (602)
Height “C” 25-5/16” (643) 25-5/16” (643) 25-5/16” (643) 25-5/16” (643) 25-5/16” (643) 25-5/16” (643)
A minimum of 6” of clearance should be allowed around the entire unit for proper performance. Additional clearance should be considered for
above the unit and in front of the unit for servicability.
Frequency 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz
Phase 1 Ø 1 Ø 1 Ø 1 Ø 1 Ø 1 Ø
RLA 6.5 12.6 18.7 24.8 N/A N/A
MCA 8.7 13.9 19.9 26.2 N/A N/A
Max Fuse 15 20 25 30 N/A N/A
Current/Plug N/A N/A N/A N/A 6.5, NEMA 5-15 12.6, NEMA 5-15P
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice
2
Coolant Deck Overalls
Model GB#
ARCTICPOUR
Operation/Installation Manual
23
11
16
1/2" GLYCOL
OUTLET(S) TO
PUMP(S).
"
1/2" GLYCOL
RETURN(S)
MODEL GB#
1
"
4
MOUNTING HOLES (4)
3/8" BARB PRODUCT
CONNECTIONS
PUMP OUTLET
1/2" BARB
PUMP INLET
1/2" BARB
20
5
16
"
12
5
16
"
3
16
"
20
3
4
15
22
"
16
11
16
24
"
3
"
4
15
MOUNTING
HOLES
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice
13
5
"
25
8
PRODUCT
"
TUBES
1
"
13
4
MOUNTING
HOLES
14"
POWER CORD
(ELECTRICAL
CONNECTIONS
(7/8" KNOCKOUT))
3
5
24
I/O TUBES
"
16
Form No. Z2339
Rev. 06.10.2015
ARCTICPOUR
REFRIGERATION DECK MODEL RD060
CENTURY II
Operation/Installation Manual
3/4 HP Refrigeration Deck Overalls
Model RD060
1
"
4
MOUNTING HOLES (4)
11
MOUNTING
HOLES
13
16
"
5
1
16
"
5
3
" 30
16
5
35
OUTLET,
1/2" BARB
ON/OFF SWITCH
INLET, 1/2" BARB
MOUNTING HOLES
"
16
15
30
16
1
312"
"
513"
16
7
"
8
7
"
16
ELECTRICAL KNOCKOUT (7/8")
28 "
3
" 15
16
15
"
2
16
COVER REMOVED
FOR CLARITY.
17
1
4
1
"
4
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice
4
REFRIGERATION DECK MODEL RD120
CENTURY II
1-1/2 HP Refrigeration Deck Overalls
Model RD120
1
"
4
MOUNTING HOLES (4)
16
MOUNTING
HOLES
ARCTICPOUR
Operation/Installation Manual
13
"
5
16
1
"
8
5
1
"
33
8
15
38
OUTLET, 1/2" BARB
ON/OFF SWITCH
INLET, 1/2" BARB
MOUNTING HOLES
16
33
34
"
7
"
8
3
"
8
13
" 5
16
7
"
8
18
7
"
16
ELECTRICAL KNOCKOUT (7/8")
33
1
"
16
15
2
"
16
COVER REMOVED
FOR CLARITY.
21
3
"
8
5
"
8
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice
5
Form No. Z2339
Rev. 06.10.2015