Perlick R24NB Installation Manual

INSTALLATION AND OPERATION INSTRUCTIONS
SINGLE DOOR REFRIGERATOR
MODEL NOS.
R24N
R24S
R24S
IMPORTANT INFORMATION
This manual has been prepared to assist you in the installation of your Single Door Refrigerator and to acquaint you with its operation and maintenance.
We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction. If, however service is required, call Perlick at 1-800-777-7267 or your dealer who can provide you with a list of qualified service agents. For your own protection, never return merchandise for credit without our approval.
We thank you for selecting a Perlick product and assure you of our continuing interest in your satisfaction.
IMPORTANT WARRANTY INFORMATION
A Warranty card is enclosed that must be completed and mailed to the Perlick Corporation in order to register the warranty. If the card is not returned to Perlick, the warranty period will begin from the date the equipment is shipped from the factory.
R24N
Table of Contents
Cabinet Specifications ..........................................2
Installing
Uncrating and Inspection................................3
Plumbing.........................................................3
Electrical..........................................................3
Installing Casters or Legs ...............................3
Placing The Cabinet........................................3
Sealing the Floor.............................................4
Temperature Control .............................................4
Cleaning................................................................4
Cleaning Stainless Steel/Avoiding Corrosion .......4
Replacement Parts ............................................5/6
Wiring Diagram.....................................................7
Reversing the Doors.............................................8
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 • Fax 414-353-7069
Toll Free 800-558-5592 • E-Mail: Perlick@Perlick.com • www.Perlick.com
Form No. Z2288
Rev. 8.22.06
Installation and Operating Instructions
Single Door Refrigerator
NON-FINISHED TOP FINISHED TOP
MODEL NOS. DOOR FINISH DOOR FINISH
R24NB Black R24SB Black R24NS Stainless Steel R24SS Stainless Steel R24NG Glass w/ Black Trim R24SG Glass w/ Black Trim R24NT Glass w/ Stainless Trim R24ST Glass w/ Stainless Trim
EXTERIOR: Back, top and sides are Galvanized steel. Top and sides are stainless steel.
Back is galvanized steel.
Both models: Front is stainless steel. Doors: Either black vinyl CRS or stainless steel. Bottom: galvanized steel with stainless grille.
INTERIOR Both models: Interior liner is stainless steel. Includes two adjustable vinyl coated shelves plus
a bottom shelf. CABINET Length 24 (610) DIMENSIONS Depth 24 (mm) Height 34 INTERIOR CU. FT. (m3) 4.9 (0.14) SHELVING Bottom floor shelf and two additional shelves included CASE CAPACITY* 4.6 CONDENSING UNIT H.P. 1/6 HP RUNNING LOAD –AMPS 2.3 Ship Wt. Lbs. (kg.) 145 (54) ELECTRICAL 1 1 5V, 60Hz., 1 phase . Furnished with 3-prong, 6 foot rubber plug in cord. PLUMBING None required. Moisture drains to self evaporating condensate pan in machinery compartment. INSULATION 2 foamed-in-place polyurethane insulation. TEMPERATURE RANGE Adjustable from 32°F to +42° F (0° to 6° C). REFRIGERATION R-134A capillary tube-type. with hermetic condensing unit. Front access for condenser and cleaning. VENTILATION Front vented. OPTIONAL Set of 4 casters (3
ACCESSORIES & Set of 4 adjustable legs (6” - 7
* Capacity calculations based on use of 12oz. export bottles on standard shelving.
3
4 high) P/N 65426.
1
4 high) P/N 65423.
1
4 (615)
1
2 (887)
11 3/4
[470]
5 9/16
[141]
47 1/8
[1197]
24”
[610]
180°
DOOR SWING
34 1/2
[887]
3 11/16
[92]
20
[508]
8 [203]
8 [203]
8 7/16 [214]
30 9/16
[776]
29 1/4
[743]
Top View Front View End View
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
2
24 1/4
[615]
18 1/2
[470]
25 3/4
[654]
FINISHED
STAINLESS
TOP
NON-FINISHED
TOP
Form No. Z2288
Rev. 8.22.06
Preparing the Cabinet – Single Door Refrigerator
Uncrating and Inspection
Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transport company. Perlick is not responsible for damage in transit.
Plumbing
No plumbing connections are required. Condensate from the cooling coil is automatically evaporated through a condensate pan located in the condensing unit section.
Electrical
The cabinet must be connected to a separately fused power source (see Electrical Specification Plate) and grounded in accordance with National and Local Electrical Codes. CAUTION: Do not attempt to operate the equipment on any other power source than that listed on the Electrical Specification Plate.
Anti-tip (without Legs or casters)
To prevent the cabinet from tipping forward and to provide a stable installation, the cabinet must be secured in place with an anti-tip device.
A set of metal anti-tip brackets and installation screws (#10­brackets should be attached to the floor, at the back of the cabinet; each bracket located to catch each rear leveling leg when the cabinet is pushed backward into position.
THE ANTI-TIP BRACKETS MUST CATCH EACH OF THE LEVELING LEGS TO HAVE ASTABLE AND SAFE INSTALLATION.
Some installation sites might need to be modified to provide a secure surface for attaching the bracket. Refer to the illustration below for anti-tip mounting bracket locations.
NOTE: Do not extend leveler leg more than 3/4 out of base. Do not shim or pad to obtain levelness.
3
” wood screws) are supplied. These
4
Ø 3/8
Surface mounts to floor.
Placing the Cabinet
To assure maximum performance, fresh air must be allowed to circulate through the machinery compartment. Do not place anything in front of the cabinet that would obstruct air flow at these grilles. Do not place the unit in an unventilated small room.
Cabinet should be leveled front to back and side to side.
Installing Casters or Legs (optional)
Attach casters or legs to the mounting bracket with lockwashers and Attach bracket and leg/caster assembly to the side of the cabinet base using the tapping machine screws provided.
1
4”–20 hex head nuts provided.
1
4”–20 hex head self-
7/16
1 1/2
20 7/8
Cabinet must have at least 5/16 clearance from floor to accomodate brackets.
Shown with leg leveler engaged in anti-tip bracket.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
3
Form No. Z2288
Rev. 8.22.06
Loading...
+ 5 hidden pages