Perlick HC24TO Installation Manual

Installation Manual
for Beer Dispensing Equipment
HP15TS/TO HP24TS/TO
HC24TB/TO
15” SIGNATURE SERIES 24” SIGNATURE SERIES 24” C-SERIES
Form No. Z2349 Rev. 03/05/2014
DANGER
WARNING
DANGER
WARNING
TABLE OF CONTENTS
Dispensing Equipment Installation .....................................3
Connecting the CO2 Cylinder ................................................8
CO2 Leak Test ....................................................................................8
Mounting Hole Template ..........................................................9
CONGRATULATIONS
Congratulations on your purchase of a Perlick high quality residential Beer Dispenser. Perlick has proudly manufactured beer dispensing systems for over 50 years for bars, restaurants, stadiums, arenas and large venues around the world. That same technology is used in each and every residential beer dispenser we produce, assuring you’ll pour fresh, cold beer as the brewery intended it to be enjoyed.
IMPORTANT!
The installation of the actual beer
dispenser cabinet should happen prior
to installing the dispensing equipment.
Refer to the Installation Manual that
accompanied the Beer Dispenser for step-
by-step installation of the cabinet.
All Perlick products are built with commercial grade stainless steel, providing you with the beauty and durability for a lifetime of use. This installation guide will show you how to properly install the dispensing equipment on your Perlick Beer Dispenser.
We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction. If, however, service is required, call Perlick at 800.558.5592. For your own protection, never return merchandise for credit without our approval.
We thank you again for selecting a high quality Perlick Beer Dispenser. Cheers!
Keep CO2 cylinder away from heat. Rupture disc vents at 122°F
maximum.
Do not drop or throw regulator or CO2 cylinder.
Allow only properly trained and experienced personnel to handle
high pressure gas.
Do not apply oil to the regulator!
C
2
US
perlick.com
INSTALLATION OF DISPENSING EQUIPMENT
Open the tapping kit box and become familiar with its components. If the dispensing head is going to be mounted on a counter top directly above the refrigerated cabinet, have the counter top pre-drilled using the supplied template on page 9. Make sure that the access hole in the refrigerated cabinet is in line with the counter top holes. Remove any obstructions from the access hole of the refrigerator. Follow instructions on pages 4 through 7 to properly install the tapping equipment on your perlick unit.
Dispensing Head
Apply silicone to bottom interior
Faucet Lead
Flange Sleeve All hose connections use worm-drive hose clamps (view
enlarged to verify)
Keg
Keg Coupler
Beer Connection
NOTE: Image does not accurately reect positions of the dierent elements within the unit. Positions and hose lengths shown are to clearly illustrate proper connection methods only.
Air Distributor
Distributor is only on multiple keg units, each keg is connected to a valve on the air distributor. Single keg is connected directly to the regulator.
perlick.com
3
Loading...
+ 7 hidden pages