24" C-Series Operation / Installation Manual
Congratulations on your purchase of a Perlick residential refrigeration product. Celebrating over 90 years of excellence, Perlick is the industry leader in commercial refrigeration systems. Today, Perlick has taken its expertise and experience into creating the highest quality and most inno­vative residential products on the market. Perlick’s product offering gives you the opportunity to enjoy the functionality and user friendliness in just about any room of your home, including kitchens, bedrooms, entertain­ment rooms, basements and even bathrooms. All Perlick products are built with commercial-grade stainless steel – providing you with the beauty and durability for a lifetime of use.
This Installation and Operation manual will answer your questions about the features, operation and maintenance of your Perlick unit. If you have questions that are not addressed here, call 800/558-5592.
IMPORTANT: Please read all instructions completely before attempting to install or operate the unit. Take note of DANGER, CAUTION and WARN­ING when they appear in the manual. This information is important for the safe and efficient installation, operation and care of your Perlick unit.
DANGER indicates a hazard that will result in serious injury or death if precautions are not followed.
WARNING indicates a hazard may cause serious injury or death if precautions are not followed.
CAUTION indicates a hazard where minor injury or product damage may occur if you do not follow instructions.
WARRANTY REGISTRATION
To request information or service, the model number and serial number must be provided. This information is located on the inside ceiling of the unit and on the warranty registration card included with information pack­et shipped with the unit.
IMPORTANT: Read through the included warranty statement then com­plete and mail the Warranty Registration Card as soon as possible to val­idate the registration date. Warranty registration can also be done online at
www.bringperlickhome.com
. If warranty registration is not completed, Perlick will use the date of sale as the first date of warranty for the unit. Please record the purchase date of the unit and the dealer’s name, address and telephone number below.
Model Number _____________________________________
Serial Number _____________________________________
Purchase Date _____________________________________
Dealer Name _____________________________________
Dealer Address _____________________________________
Dealer Phone No._____________________________________
Retain this manual along with the sales receipt for future reference.
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Warranty Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Preparing the Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Preparing Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Unpacking and Moving the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Anti-Tip Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Shelving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Door Panel Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Wood Overlay Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Wooden Wine Rack Trim Finishing . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Interior Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Loading Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Temperature Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Checking Product Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Cleaning the Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
© 2008
2
24" C-Series Operation / Installation Manual
GENERAL PRECAUTIONS
DANGER
Risk of child entrapment. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside.
DANGER
Altering or cutting of the power cord, or removal of the power plug, or direct wiring can cause serious injury, fire and/or loss of property and/or life and will void the warranty.
WARNING
• Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected.
• The anti-tip kit must be installed on this unit before it is used. Never use the shelves or doors as steps or to sup­port more than they are designed to support.
CAUTION
• Do not lift unit by shelves or door handle.
• Failure to clean the condenser every three months can cause the unit to malfunction. This could void the warranty.
• Never install the unit behind closed doors. Be sure front louvered toe plate is free of obstruction. Obstructing free air flow can cause unit to malfunction and may void the warranty.
CAUTION
Use only Perlick replacement parts. Imitation parts can dam­age the unit, and may void the warranty.
INSTALLATION SPECIFICATIONS
General
• All electrical instructions assume that outlet is located 4-10 inches from the floor.
• Floor must be level in area of installation. Leg levelers are used for fine-tune adjustment only and should not be used to compensate for floor differences exceeding 1/2".
• When moving unit into position, take care to protect floor surface with cardboard, rugs, etc.
50” area in which
electrical outlet must be located
13
1
/16” distance
same on both sides of cabinet
4
1
/2” min.
clearance to side wall on corner installation
24
25
/32” door swing clearance
98° min. door swing
for pull-out shelf
clearance
25
27
/64
23
15
/16
22
1
/8
3
39
/64
1
53
/64
23
7
/8
34
5
/16””
• Never attempt to move unit without the aid of at least one other per­son.
• Always secure doors shut prior to moving the unit.
Finished Rough Opening Requirements
• Height: 34-1/2"
• Depth: 24"
• Width: 24"
Figure 1. Dimensions
© 2008
3
24" C-Series Operation / Installation Manual
PREPARING THE SPACE
Make sure the installation opening is properly prepared. Refer to Figure 1 for space dimensions.
CAUTION
If unit is to be installed under a countertop, it is recommend­ed that the countertop be supported by a structure other than the unit itself, to prevent damage to the countertop.
IMPORTANT: For a cabinet door to operate properly, the door must open
a minimum of 100° (see Figure 1). Use a minimum 4-1/2" filler in corner installations to ensure a 100° opening. Allow enough clearance in front of the unit for full door swing or shelf pull-out.
IMPORTANT: Make sure floor under unit is level with the surrounding finished floor. Protect a finished floor with plywood, cardboard or some other suitable material before moving the unit into place. Failure to do this may result in damage to the floor.
PREPARING ELECTRICAL CONNECTIONS
A 115 volt, 60Hz, 15 amp circuit breaker and electrical supply are required. A separate circuit is recommended
Follow the National Electrical Code along with local codes and ordinances when installing the receptacle.
All Perlick units come equipped with a NEMA 5-15P, 90° plug with a 5’ cord (minimum) extending beyond the rear of the unit. The electrical out­let must be flush with, or recessed into, the back wall.
DANGER
ELECTROCUTION HAZARD!
Electrical grounding required. This appliance is equipped with a 3-prong (grounding) polarized plug for protection against possible shock hazards.
• Never remove the round grounding prong from the plug.
• Never use a 2-prong grounding adapter.
• Never use an extension cord to connect power to the unit.
If a 2-prong wall receptacle is encountered, or a longer power cord is required, contact a qualified electrician to install the proper 3-prong receptacle in accordance with applicable electrical codes.
DANGER
Failure to comply with the above electrical guidelines may result in possible injury/death/fire or loss of property.
UNPACKING AND MOVING THE UNIT
CAUTION
Do not cut cardboard sleeve covering the unit. Cutting may result in damage to the exterior of the unit.
1. Uncrate the unit outside on a flat level surface. Remove the cardboard
sleeve by removing the banding holding the sleeve to the shipping base. Carefully lift the cardboard sleeve up over the top of the cabi­net.
2. Carefully lift unit off base and onto a hand truck or dolly (this should be done with a minimum of two people, larger cabinets may require additional helpers). Make sure unit is balanced on transporting device. Secure unit to transporting device using soft flexible strap­ping. Protect cabinet surfaces with cloth material where strapping contacts the unit.
3. Before moving unit, secure door to unit with tape to hold the door closed.
WARNING
A minimum of two people should lift the cabinet off the base to prevent possible personal injury.
4. Carefully move unit to installation site and place in front of opening.
ANTI-TIP BRACKETS
WARNING
Unit may tip forward if loaded racks/shelves are all pulled out at the same time. To prevent tipping and provide a stable installation, the unit must be secured in place with the anti­tip brackets provided with the unit.
A set of metal anti-tip brackets and #10 x 3/4" screws are supplied with the unit. The anti-tip brackets, when properly installed, should secure the rear legs and prevent the unit from tipping forward.
Some installation sites may require modification to provide a secure sur­face for attaching the brackets. Refer to Figure 2 for mounting bracket locations.
IIMMPPOORRTTAANNTT::
If installing on a concrete floor, concrete fasteners are
required and are not included in the Anti-Tip kit.
15
/16
22
1
/32
3
/16
0
3
/8
Anti-Tip Bracket Part #63740
Front of Unit
Top Vie w
Figure 2. Anti-Tip-Over Bracket Mounting
Loading...