Perlick HC24RS, HC24WS, HC24FS Installation And Operation Instructions Manual

Installation and Operating Instructions
50” AREA IN WHICH ELECTRICAL
OUTLET MUST BE LOCATED
*41/4” MIN.
CLEARANCE
FROM A CORNER
TO ACHIEVE
REQUIRED
DOOR SWING
*VALUES MAY CHANGE DUE
TO CUSTOM PULL
WITH A WOOD
OVERLAY DOOR
*255/16
221/8
2315/16
2425/32” MIN.
CLEARANCE
FOR DOOR
SWING
237/8
34”
319/32
83/8
93/8
71/2
98° SWING
REQUIRED FOR
PULL-OUT SHELF
CLEARANCE
STANDARD LEVELERS
INCREASE CABINET
HEIGHT 1/4”
REF/FREEZ
Specifications - 24" Custom Series Refrigerator/Froster/Wine Reserve
7
8” (607) 237⁄8” (607) 237⁄8” (607)
15
/16” (608)
Cabinet Dimensions
Length - Inches (mm) 23 Depth - Inches (mm) 23 Height - Inches (mm) 34” (870) 34” (870) 34” (870)
15
23
/16” (608) 23
15
/16” (608)
INTERIOR VOLUME - CUBIC FOOT (m3) 5.3 (0.15) 5.3 (0.15) 5.3 (0.15) SHELVING 2 Full Extension Shelves 2 Full Extension Shelves 5 Full Extension Wine Racks CAPACITY* 5 cases 86 glasses 45 wine bottles TEMPERATURE RANGE 32°F to 42°F (0C to 6C) -10°F to +10°F (-23C to -12C) 45°F to 65°F (7C to 18C) RUNNING LOAD AMPS 2.3 2.3 2.3 CONDENSING UNIT H.P. 1/6 HP 1/6 HP 1/6 HP SHIP WT. L INTERIOR EXTERIOR
REFRIGERATION
bs. (kg.) 195 (89) 195 (89) 215 (98)
All stainless steel interior.
Stainless steel top, sides and grille, galvanized back and bottom. See door finishes under optional accessories.
R-134a capillary tube-type with hermetric compressor. Front access condenser. Froster equipped with
automatic 4 hour hot gas defrost cycle and manual 6 hour defrost with auto restart. ELECTRICAL 115V, 60Hz., 1 phase, furnished with 3-prong NEMA 5-15P plug, 6 foot long cord. PLUMBING None required. Moisture drains to self evaporating condensate pan. VENTILATION OPTIONAL
ACCESSORIES & MODIFICATIONS
Front vented.
• Leg set Customer choice of laminate
• Caster Set Powder coated (color options)**
• Door Lock Brass hardware (classic, 12" & full length) or pull tab
Door Finishes
Prepared for field lamination Glass door with black vinyl frame
Glass door with stainless steel frame Black vinyl coated Glass door with laminated frame Stainless steel Glass door with powder coated frame**
* Froster - glass size 3” diameter. Refrigerator - 12 oz. long neck bottles. Wine - 750ml wine bottles. ** Call Milwaukee or see our web site for standard or custom color options.
HC24RS Only
Form No. Z2288 Rev. 05.21.10
Top View Front View End View
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
2
Preparing the Cabinet
15/16”
22 1/32”
Cabinet must have at least 5/16” clearance from floor to accomodate brackets.
Shown with glide engaged in anti-tip bracket.
Surface mounts to floor.
Ø 3/8”
3/16”
Uncrating and Inspection
Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transport company. Perlick is not responsible for damage in transit.
Plumbing
No plumbing connections are required. Condensate from the cooling coil is automatically evaporated through a condensate pan located in the condensing unit section.
Electrical
The cabinet must be connected to a separately fused power source (see Electrical Specification Plate) and grounded in accordance with National and Local Electrical Codes.
Do not attempt to operate the equipment on
any other power source than that listed on the
Electrical Specification Plate.
CAUTION
:
Anti-tip (without Legs, Casters or Rollers)
To prevent the cabinet from tipping forward and to provide a stable installation, the cabinet must be secured in place with an anti-tip device.
A set of metal anti-tip brackets are supplied. These brackets should be attached to the floor, at the back of the cabinet; each bracket located to catch each rear glide when the cabinet is pushed back into position.
THE ANTI-TIP BRACKETS MUST CATCH EACH OF THE GLIDES TO HAVE A STABLE AND SAFE INSTALLATION.
Some installation sites might need to be modified to provide a secure surface for attaching the brack­et. Refer to the illustration below for anti-tip mount­ing bracket locations.
Installing Casters or Legs (optional)
Remove existing cabinet glides. Attach bracket assembly to the bottom of the cabinet base using the 1⁄4”–20 Phillips head machine screws provided. Attach casters or legs to the mounting bracket with
1
4”–20 Phillips head screws provided.
NOTE: To comply with NSF requirements, cabinet must be sealed to floor or on legs, casters or rollers.
Placing the Cabinet
To assure maximum performance, fresh air must be allowed to circulate through the machinery compartment. Do not place anything in front of the cabinet that would obstruct air flow at these grilles. Do not place the unit in an unventilated small room.
Cabinet should be leveled front to back and side to side.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
3
Form No. Z2288
Rev. 05.21.10
Preparing the Cabinet
BEAD SILICON SEALER (RTV)
FLOOR
CABINET
Sealing the Cabinet
For sanitation purposes, it may be necessary to seal the base of the cabinet to the floor. This can be accomplished by laying a bead of silicone seal­ant between the base of the cabinet and the floor as shown by the figure below.
When sealing the cabinet to the floor, make sure that the louvered front grille plate can still be removed for condenser maintenance and cleaning.
CAUTION
:
Finished flooring should be protected with
appropriate material to avoid damage from
moving the unit.
If unit has been laid on its back or sides, place unit upright and allow minimum of 24 hours before connecting power.
Plug the unit into the 15 amp grounded outlet located in the installation opening. With power applied to the unit, check that lighting and cooling function operate properly, then turn off power to wall outlet at the circuit breaker.
CAUTION
:
To prevent damage to the counter top and unit underneath, do not place heavy objects on the
counter top directly above the unit.
Check interior door openings inside unit and ensure unit is level.
Form No. Z2288 Rev. 05.21.10
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
4
Loading...
+ 8 hidden pages