Drain Pump Kit for Undercounter Clear Ice Maker
For use with H50IM Series Clear Ice Makers
Check to ensure all parts are included:
Index
No. Description Qty.
1 Drain Pump Assembly 1
2 Vinyl Hose (drain hose) (5/8” ID x 6.5”) 1
3 Vinyl Hose (drain hose) (3/8” ID x 27.5”) 1
4 High Pressure Clear PVC Hose (discharge hose) (1/2” I.D.× 10’) 1
5 Small Clamp (vent hose to drain pump) 1
6 Medium Clamp (discharge hose to drain pump) 1
7 Large Clamp (drain hose/drain elbox to ice maker and drain pump) 2
8 Hose Clips (vent hose) 2
8a Truss Head Screw (4×8, SS) 2
Perlick Drain Pump
Catalog No. 63802A (Part No. HS-5061)
WARNING
• Only qualied service technicians should install and service this drain pump to reduce the risk of death, electric shock,
serious injury or re. A plumbing permit and the services of a licensed plumber may be required in some areas.
• No installation or service should be undertaken until the technician has thoroughly read these instructions. Failure to
install, prime, operate, and maintain this drain pump in accordance with these instructions will adversely aect safety,
performance, component life, and warranty coverage and may result in costly water damage.
• Proper installation is the repsonsibility of the installer. Product failure or property damage due to improper installation is
not covered under the warranty.
• See the instruction manual provided with the icemaker for icemaker installation. Failure to install the icemaker within
these guidelines many adversely aect safety, performance, component life, and warranty coverage.
• Clean, sanitize and maintain the icemaker per the instructions provided in the icemaker’s instruction manual. If the
instruction manual is not available, consult with your local distributor or call Perlick Technical Service Support at (800)
558-5592 in the USA.
• THE ICEMAKER MUST BE GROUNDED: The icemaker is equipped with a 3-prong grounding plug to reduce the risk of
potential shock hazards. It must be plugged into a properly grounded, independent 3-prong wall outlet. If the outlet
is a 2-prong outlet, it is your personal responsibility to have a qualied electrician replace it with a properly grounded,
independent 3-prong wall outlet. Do not remove the ground plug from the power cord and do not use an adapter plug.
• The icemaker and this kit must be installed in accordance with applicable national, state, and local codes and
regulations.
• Protect the oor when moving the icemaker to prevent damage to the oor.
• This drain pump is approved for use only with the models listed.
Form No. Z2334A, 02/25/2013
1
Drain Pump Kit for Undercounter Clear Ice Makers
For use with H50IMS, H50IMW and H50IMS-AD Clear Ice Makers
INSTALLATION INSTRUCTIONS
This drain pump is designed to remove drain water from an
undercounter icemaker in areas without direct drainage access.
The drain pump reservoir collects drain water and pumps it
through a 1/2” ID high pressure clear pvc hose (discharge hose).
The maximum discharge hose length is 20 feet. The maximum
lift height is 8 feet. There is a factory installed check valve on the
drain pump.
NOTICE! Do not install any additional check valves.
1. Move the control switch to the “OFF” position and unplug
the unit from the electrical outlet.
2. Remove the rear access panel and rear cover (see Fig. 1).
Disconnect the drain house and remove the rear drain
bracket and drain tting.
3. If the sheet metal tabs are present on your unit, remove
them (see Fig. 2).
Fig. 1
4. Remove the original drain hose and install the new drain
hose (5/8” ID×6.5”) provided in this kit (see Fig. 3). On -AD,
cut the new drain hose to a length of 5”. Secure the new
drain hose with one of the large clamps provided in this kit.
CAUTION! Do not over-tighten the clamp.
Fig. 2
Fig. 3
2
Form No. Z2334A
Drain Pump Kit for Undercounter Clear Ice Makers
For use with H50IMS, H50IMW and H50IMS-AD Clear Ice Makers
5. Carefully place the drain pump into the open space
provided at the rear of the icemaker. The drain pump will
overhang the base slightly. (See Fig. 4). If necessary, care-
fully bend or move the icemaker’s copper tubing so that
it does not make contact with the drain pump, hoses, or
other parts of the icemaker.. CAUTION! Drain pump MUST
be level.
6. Connect the drain hose/drain elbow to the drain pump as
illustrated (see Fig. 4). Secure the drain hose/drain elbow
with the remaining large clamp provided in this kit.
Fig. 4
CAUTION! Do not over-tighten the clamp.
7. Remove the jumper plug from the icemaker’s drain pump
connector. (See Fig. 5). The jumper plug is not needed when
a drain pump is installed.
8. Connect the drain pump plug to the icemaker’s drain
pump connector.
Continued on page 4
Form No. Z2334A
Fig. 5
3