INSTALLATION AND OPERATION INSTRUCTIONS
4400QC SERIES POWER PAKS
4400QC Series
MODELS
4410QC
4414QC
4420QC
IMPORTANT INFORMATION
To register your product, visit our web site at www.
perlick.com. Click on Commercial, then Service.
You will see the link to Warranty Registration Form.
You must complete and submit this form or the
installation date will revert back to the ship date.
Permanently mount the enclosed Warning/Safety
Instruction label in a visible location near the CO2
regulator.
This manual has been prepared to assist you in the
installation of your 4400QC Series Power Pak and to
acquaint you with its operation and maintenance.
We dedicate considerable time to ensure that our
products provide the highest level of customer
satisfaction. If service is required, your dealer can
provide you with a list of qualified service agents. For
your own protection, never return merchandise for
credit without our approval.
C
US
Table of Contents
Sizes & Specications ............................................ 2-3
General Information .......................................... 3
Installation ..................................................... 3-4
Connecting Power Pak to Trunk Housing ........... 4-5
Power Pak Start-Up ................................................ 5-6
LEDS ...................................................................... 6-7
Preventative Maintenance ...................................... 6-7
Replacement Parts .................................................... 7
Wiring Diagrams ........................................................ 8
We thank you for selecting a Quck Chill product and
assure you of our continuing interest in your
satisfaction.
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414.353.7060 • Fax 414.353.7069
Toll Free 800.558.5592 • E-Mail perlick@perlick.com • www.perlick.com
Form No. Z0507QC
Rev. 12.14.2016
INSTALLATION AND OPERATING INSTRUCTIONS
4400QC SERIES POWER PAKS AIR COOLED
MODEL NOS. 4410QC 4414QC 4420QC
DIMENSIONS:
EXTERIOR (mm)
ELECTRICAL Voltage 120 V 120 V 208/230 V**
SINGLE PUMP RLA (Rated Load Amps) 12.5 15.4 16.5
DUAL PUMPS
(add -2 to model #)
TRIPLE PUMPS
(add -3 to model #)
COMPRESSOR 1/2 HP 3/4 HP 1.5 HP
EVAPORATOR RATING
@ 20°F (BTUH)
HEAT REJECTION (MAX) 6080 9600 19200
REFRIGERANT R-134a R-134a R-134a
SHIPPING WEIGHT LBS (kg) 153 (69) 180 (82) 255 (116)
MAXIMUM FOOTAGE IN SYSTEM* 250 ft. 300 ft. (1 pump)
CABINET Stainless Steel
CIRCULATING PUMP 70 GPH / 80 PSIG
RESERVOIR CAPACITY 1.75 gal 1.75 gal 1.75 gal
REFRIGERATION Constant Pressure Expansion Valve, Condensing Unit with Service Valves
REFRIGERANT CHARGE (grams) 8.0 oz/227 g 9.5 oz/269 g 16.0 oz/453 g
GLYCOL CONCENTRATION 33% 33% 33%
Length “A” 24
Width “B” 17
Height “C” 25
A minimum of six inches of clearance should be allowed around the entire unit for proper performance.
Additional clearance should be considered for above the unit and in front of the unit for servicability.
Frequency 60 Hz 60 Hz 60 Hz
Phase 1 Ø 1 Ø 1 Ø
MCA (Min. Circuit Ampacity) 17.7 19.6 23.9
RLA (Rated Load Amps) 18.6 21.0 19.3
MCA (Min. Circuit Ampacity) 23.8 25.2 26.7
RLA (Rated Load Amps) N/A N/A 22.1
MCA (Min. Circuit Ampacity) N/A N/A 29.5
1/4
” (616) 24
1/4
” (438) 17
1/2
” (648) 25
3800 6000 12000
1/4
” (616) 26
1/4
” (438) 20
1/2
” (648) 31” (782)
400 ft. (2 pumps)
3/4
” (679)
1/4
” (519)
300 ft. (1 pump)
600 ft. (2 pumps)
850 ft. (3 pumps)
*Based on 75° Ambient
C
US
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice
2
GENERAL INFORMATION 4400QC SERIES POWER PAKS
Accessories
Power Cord Kit
C22296A-20--12/3 Cord, 20A, Nema Plug 5-20P,
Dedicated Circuit Models—See electrical specifications
Power Pak Racks
61790, 61790+1, 61790+2—All Models
Power Pak Wall Mounting Brackets
4408 - For Models 4404 & 4410 only
Coolant Solution-63299-1
One gallon Quick Chill Coolant solution, 33% DowFrost
HD/67% Distilled Water
Coolant Connector Kit
C23015—All Models
Leg Set - All Models
57782 . . . Set of four, 5
Pump Kits
4430QC—Pump kit, 115V, 6.1 A, 70 gph, 80 psig
Models 4410, 4410W
4431QC—Pump Kit, 115V, 5.6 A, 70 gph, 80 psig
Models 4414, 4414W
4432QC—Pump Kit, 230V, 2.8 A, 70 gph, 80 psig
Models 4414-230, 4420
3
/4”-71/2” adjustable legs
PRODUCT DESCRIPTION
Power Paks have always been an integral part of a
Beer System. The 4400QC Series Power Pak
product line has been expanded to satisfy longer beer
runs. A Power Pak circulates coolant solution (food
grade propylene glycol with distilled water)
from the walk-in cooler to the dispensing station(s)
and back, maintaining the desired dispensing
temperature at the faucet. The 4400QC Series Power
Paks incorporate a 1/3 hp ball bearing, maintenance
free motor with a 70 gallon per hour 80 psig positive
displacement pump for optimum performance. The
4400QC series Power Pak product line employs a
direct expansion form of refrigeration increasing the
units’ efficiency as well as making the units more
compact. These units also employ an electronic
temperature control with digital readout. This state of
the art control, controls the performance of the unit as
well as giving the user a visual indication of how the
unit is working as well as early indication if
something may be going wrong through the use of
internal alarms.
INSTALLATION - 4400QC Series Power Paks
IMPORTANT SAFETY WARNINGS!
• Follow all National and Regional Codes.
• Read Installation and Operating Instructions carefully before attempting to install, operate or maintain the
product.
• Protect yourself and others by observing all safety information.
• Electrical hazards exist and can cause injuries if not serviced by properly trained personnel.
• Failure to comply with instructions could result in personal injury and/or property damage!
• Retain instructions for future reference.
• Never operate the circulating pump without coolant in the reservoir.
NOTE: Air-cooled Power Paks must be installed in areas with adequate ventilation to maintain ambient
temperatures of less than 105°F to achieve optimum performance and satisfy warranty requirements.
INSTALLING THE POWER PAK
Prior to installing a 4400QC Series Power Pak, it is imperative that the method of connecting it to the electrical
service has been determined. Ensure that the electrical service to power the Power Pak will handle the load
requirements. Perlick has a Power Cord specifically designed for a Power Pak, which has a RLA of 16 amps
or less, and a MCA of 20 amps or less. All units with RLA greater than 16 amps and a MCA of greater than
20 amps should have the Power Pak hard-wired to electrical service.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice
3
Form No. Z0507QC
Rev. 12.14.2016