Perle Systems S-100MM-XXXXX User Manual

Page 1
Perle Fast Fiber to Fiber
Media Converters
Installation Guide
S-100MM-XXXXX
P/N 5500312-10
Page 2
Overview
This document contains instructions necessary for the installation and operation of the Perle Fast Fiber to Fiber Standalone Media Converters (S-100MM). These products allow dissimilar 100Base­X fiber interfaces to connect to one another.
These are the fiber to fiber conversion models:
Multimode to Multimode (MM)
Multimode to Single Mode ..(SM)
Multimode to Single Mode Single Strand (SM)
The first fiber port will be MM and the second fiber port can be either single mode (SM) or multimode (MM) depending on the model selected. They can operate over different wavelengths and distances. (See tables below).
Fiber port 1 – MM1
Model Connector Mode Distance All models SC/ST/LC MM. 2 km/1.2 mi 1310 nm
Fiber port 2 – MM2/SM2
Model Connector Mode Distance
S-100MM-M2xx2 SC/ST/LC MM 2 km/1.2 mi. 1310 nm S-100MM-S2xx20 SC/ST/LC SM. 20 km/12.4 mi. 1310 nm S-100MM-S2xx40 SC/ST/LC SM 40 km/24.9 mi. 1310 nm S-100MM-S2xx80 SC/ST/LC SM 80 km/49.7 mi. 1550 nm S-100MM-S2xx120 SC/ST/LC SM 120 km/74.6 mi 1550 nm S-100MM-S1SC20U SC SM 20 km/12.4 mi. 1310/1550 nm S-100MM-S1SC20D SC SM 20 km/12.4 mi. 1550/1310 nm S-100MM-S1SC40U SC SM 40 km/24.9 mi. 1310/1550 nm S-100MM-S1SC40D SC SM 40 km/24.9 mi. 1550/1310 nm
Wavelength (TX/RX)
Wavelength (TX/RX)
Note: Please refer to Perle’s web site for the most up to date Installation guides, models and specifications:
http://www.perle.com/
Page 3
Installation
The default switch settings (all switches in the UP position) will work for most installations.
These are the steps required to configure the Perle Fast Fiber to Fiber media converter:
1. Set the DIP switch settings (optional).
2. Install and connect the fiber cable to port MM1.
3. Install and connect the fiber cable to port MM2/SM2.
4. Power up the media converter.
DIP Switches
The DIP switches are accessible through the opening in the side of the enclosure
Note: All switch changes take effect immediately and will result in a link reset on both fiber ports.
Page 4
DIP Switch Settings
Link Mode (Switch 1)
Switch Position Mode
Up (default) Link Pass-Through Mode Down Standard Mode
Link Pass-Through: In this mode, the link state on one fiber connection is directly reflected through the media converter to the other fiber connection.
For example, if a Far End Fault (FEF) indication is received on port MM1, the media converter in turn sends a signal to turn off the transmitter on port MM2/SM2. When the Far-End Fault indication is cleared the transmitter is then turned back on.
Standard Mode: In this mode, the links on the fiber side can be brought up and down independently of each other. A loss of link on either fiber connection can occur without affecting the other fiber connection.
Far End Fault (Switch 2)
Switch Position
Up (default) Enabled
Mode
Down Disabled
Enabled: If the media converter detects a loss of fiber signal on the fiber receiver, the media converter will immediately send a FEF on the fiber link. This, in effect, notifies the fiber link partner that an error condition exists on the fiber connection.
If the remote media converter is set up for Far End Fault (FEF) and the local media converter is set up with Link Pass-Through, a loss of fiber link on either the transmit or receive link will be passed through to the end fiber connection.
Disabled: Far End Fault indications are not transmitted regardless of the condition of the receive signal on the 100BASE-FX fiber connection.
Page 5
Note: This switch needs to be set to either generate or detect the FEF signal.
Illustration of the FEF feature
Media Converter A Configuration
Link Mode–Standard Mode Far-End Fault–Enabled
Media Converter B Configuration
Link Mode–Link Pass Through Mode Far-End Fault–Enabled
Sequence of Events
1. Media Converter A loses fiber connection (RX) on MM2/SM2.
2. Media Converter A sends FEF on transmitter (TX) MM2/SM2.
3. Media Converter B detects loss of fiber link on receiver RX –
MM2/SM2.
4. Media Converter B turns off transmitter (TX) on MM1/SM1.
5. Media Converter A MM1 is not affected
Page 6
Remote Loopback Fiber 1 (Switch 3)
Switch Position
Up (default) Disabled Down Enabled
Disabled: The loopback feature is disabled. This is the normal position for regular operation. The switch must be set to this position in order for data to pass through the media converter.
Enabled: This is a test mode. All data received on the receive (RX) fiber connection on port MM1 is looped back to the transmit (TX) fiber connection.
Note: Only one fiber interface can be in loopback at a time.
Mode
Remote Loopback Fiber 2 (Switch 4)
Switch Position
Up (default) Disabled Down Enabled
Disabled: The loopback feature is disabled. This is the normal position for regular operation. The switch must be set to this position in order for data to pass through the media converter.
Mode
Enabled: This is a test mode. All data received on the receive
(RX) fiber connection on port MM2/SM21 is looped back to the transmit (TX) fiber connection.
Note: Only one fiber interface can be in loopback at a time.
Page 7
Installing the Duplex Fiber Cable
Locate a 100Base-X compliant duplex (2 strands) fiber cable with appropriate connectors.
Connect the fiber cables from one media converter to the other media converter/switch/fiber device ensuring that the RX and TX are reversed at the opposite end.
Installing the Simplex Fiber Cable
Locate a 100Base-X compliant simplex (1 strand) fiber cable with appropriate connectors.
Connect the fiber cable from one Media Converter Module to another Media Converter/switch/fiber device.
Powering up the Media Converter
1. Connect the Perle supplied power adapter to the media converter.
2. Turn on the power at source.
3. Check that the PWR LED light is lit and on solid.
Page 8
Operation
Status LED
The Perle Fast Fiber to Fiber Media converters have three single colored status LEDs located on the front panel of the unit.
PWR - Power/Test
On: Power is on and in normal operation.
Blinking slowly: the unit is in loopback mode.
Blinking quickly: the unit has a hardware error.
LK1 – MM1 (Fiber Link 1) Activity
On: Fiber link present.
Blinking quickly: Fiber link present and receiving data.
OFF: No fiber link present.
LK2 – MM2/SM2 (Fiber Link 2) Activity
On: Fiber link present.
Blinking quickly: Fiber link present and receiving data.
OFF: No fiber link present.
Page 9
Troubleshooting
General
Ensure power is supplied to the media converter – use of the
supplied power adapters is highly recommended.
Ensure both devices on either end of the fiber are compatible.
If using a simplex fiber connection, ensure that you have both an Upstream (U) and Downstream (D) media converter.
Ensure all cabling is of the correct type and is in good working
condition.
For duplex fiber connections, ensure the RX and TX has been
reversed between the two media converters.
No connectivity
If unable to get full connectivity with all DIP switches in the UP position, this procedure is recommended for troubleshooting.
Method 1
1) Set the Link mode to Standard (SW1 – Down) on both media converters. Leave all other switches in the Up position.
2) Connect the near end device to port MM1, the LK1 LED should be lit to indicate a good fiber connection. If the LK1 LED is not lit, then check the fiber cable and the attached device.
3) Repeat step 2 for port MM2/SM2.
4) Return units to desired configuration.
Method 2:
The fiber connection can also be verified by configuring the remote media converter for loopback mode. The link LEDs on both media converters should be lit. Data should pass through the local converter, over the fiber connection to the remote media converter. At the remote media converter, the data will be looped back and passed back through the fiber.
Page 10
Technical Specifications
The following applies to all S-100MM media converters:
Power Input/Consumption 12V DC /3.5 W Operating Temperature: 0°C to 50°C (32°F to 122°F) Storage Temperature: -25°C to 70°C (-13°F to 158°F) Operating Humidity: 5% to 90% non-condensing Storage Humidity: 5% to 95% non-condensing Operating Altitude: Up to 3,048 m (10,000 ft) MTBF: 432,138 hours MTBF (with power supply): 274,804 hours Weight: 0.3 kg (0.66 lbs) Dimensions: 80 mm x 120 mm x 26 mm
Fiber Optic Specifications:
Fiber port 1 – MM1
Model Mode
All models MM
Fiber port 2 – MM2/SM2
Model Mode
S-100MM-M2SC2 MM
S-100MM-M2ST2 MM
S-100MM-M2LC2 MM
S-100MM-S2SC20 SM
S-100MM-S2ST20 SM
S-100MM-S2LC20 SM
S-100MM-S2SC40 SM
S-100MM-S2ST40 SM
Wavelength
(nm)
TX: 1310 RX: 1310
Wavelength
(nm)
TX: 1310 RX: 1310
TX: 1310 RX: 1310
TX: 1310 RX: 1310
TX: 1310 RX: 1310
TX: 1310 RX: 1310
TX: 1310 RX :1310
TX: 1310 RX :1310
TX: 1310 RX :1310
TX Power
(dB)
Min: -20 Max: -12
TX Power
(dB)
Min: -20 Max: -12
Min: -20 Max: -12
Min: -20 Max: -12
Min: -18 Max: -7
Min: -15 Max: -8
Min: -15 Max: 0
Min: -5 Max: 0
Min: -5 Max: 0
RX Power
(dB)
Min: -31 Max: -14
RX Power
(dB)
Min: -31 Max: -14
Min: -31 Max: -14
Min: -30 Max: -14
Min: -32 Max: -3
Min: -32 Max: -3
Min: -34 Max: -5
Min: -34 Max: -3
Min: -34 Max: -3
Budget (dB)
11
Budget (dB)
11
11
10
14
17
19
29
29
Fast Fiber to Fiber Media Converter – Installation Guide 10
Page 11
Model Mode
S-100MM-S2LC40 SM
S-100MM-S2SC80 SM
S-100MM-S2ST80 SM
S-100MM-S2LC80 SM
S-100MM-S2SC120 SM
S-100MM-S2ST120 SM
S-100MM-S2LC120 SM
S-100MM-S1SC20U SM
S-100MM-S1SC20D SM
S-100MM-S1SC40U SM
S-100MM-S1SC40D SM
Wavelength
(nm)
TX: 1310 RX :1310
TX: 1550 RX: 1550
TX: 1550 RX: 1550
TX: 1550 RX: 1550
TX: 1550 RX: 1550
TX: 1550 RX: 1550
TX: 1550 RX: 1550
TX: 1310 RX: 1550
TX: 1550 RX:1310
TX: 1310 RX:1550
TX: 1550 RX:1310
TX Power
(dB)
Min: -5 Max: 0
Min: -5 Max: 0
Min: -5 Max: 5
Min: -5 Max: 0
Min: 0 Max: 5
Min: 0 Max: 5
Min: 0 Max: 5
Min: -14 Max: -8
Min: -14 Max: -8
Min: -8 Max: -3
Min: -8 Max: -3
RX Power
(dB)
Min: -34 Max: -3
Min: -34 Max: -3
Min: -34 Max: -3
Min: -34 Max: -3
Min: -35 Max: -3
Min: -35 Max: 0
Min: -35 Max: -3
Min: -32 Max: -3
Min: -32 Max: -3
Min: -33 Max: -3
Min: -33 Max: -3
Budget (dB)
29
29
29
29
35
35
35
18
18
25
25
Fiber Cabling Requirements:
MM: 50/125 microns
62.5/125 microns
SM: 9/125 microns
Note: Please refer the product page on the Perle website for the most up to date specifications.
http://www.perle.com/
Fast Fiber to Fiber Media Converter – Installation Guide 11
Page 12
Compliance Information
FCC
This product has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this Guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense.
EN 55022 Class B EN 55024 Class A
Note: When used with a power adapter providing low conducted emissions, the S-100 will comply with Class B requirements.
Laser Safety – IEC 60825-1:2007
This product meets Class I Laser safety requirements per IEC-60825-1:2007 standard and complies with FDA/CDRH 21 CFR1040.10 and 21 CFR1040.11. WARNING: Visible and invisible laser radiation may be present when cables are not connected. Do not stare into the beam or view the beam directly with optical instruments. Failure to observe this warning could result in an eye injury or blindness. WARNING: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.
Fast Fiber to Fiber Media Converter – Installation Guide 12
Page 13
Warranty / Registration
Perle’s standard Lifetime Warranty provides customers with return to factory repairs for Perle products that fail under the conditions of the warranty coverage. Details can be found at:
http://www.perle.com/support_services/warranty.shtml
Contacting Technical Support
Contact information for the Perle Technical Assistance Center (PTAC) can be found at the link below. A Technical Support Query may be made via this web page.
www.perle.com/support_services/support_request.shtml
Copyright
© 2011 Perle Systems Limited
All rights reserved. No part of this document may be reproduced or used in any form without written permission from Perle Systems.
Fast Fiber to Fiber Media Converter – Installation Guide 13
Loading...