Perle Systems S-1000MM-XXXXXX User Manual

Page 1
Perle Gigabit
Fiber to Fiber
Media Converters
Installation Guide
S-1000MM-XXXXXX
P/N 5500314-11
Page 2
Overview
(TX/RX)
(TX/RX)
This document contains instructions necessary for the installation and operation of the Perle Gigabit Standalone Fiber to Fiber Media Converters (S-1000MM). These products allow dissimilar 1000Base-X fiber interfaces to connect to one another.
These are the fiber to fiber conversion models:
Multimode to Multimode (MM)
Multimode to Single Mode (SM)
Multimode to Single Mode Single Strand (SM)
The first fiber connection will be multimode (MM) and the second fiber port can be either single mode (SM) or multimode (MM) depending on the model selected. They can operate over different wavelengths and distances. (see tables below).
Fiber port 1 – MM1
Model Connector Mode Distance
All models SC/ST/LC MM. 550 m/1804 ft. 850 nm
Fiber port 2 – MM2/SM2
Model Connector Mode Distance
S-1000MM-M2xx05 SC/ST/LC MM 550 m/1804 ft. 850 nm S-1000MM-M2xx2 SC/ST/LC MM 2 km/1.2mi. 1310 nm S-1000MM-S2xx10 SC/ST/LC SM 10 km/6.2 mi 1310 nm S-1000MM-S2xx40 SC/ST/LC SM 40 km/24.9 mi 1310 nm S-1000MM-S2xx70 SC/ST/LC SM 70 km/43.5 mi 1550 nm S-1000MM-S2xx120 SC/ST/LC SM 120 km/74.6mi 1550 nm S-1000MM-S2xx160 SC/ST/LC SM 160 km/100 1550 nm S-1000MM-S1SC10U SC SM 10 km/6.2 mi. 1310/1490 nm S-1000MM-S1SC10D SC SM 10 km/6.2 mi. 1490/1310 nm S-1000MM-S1SC20U SC SM 20 km/12.4 mi. 1310/1490 nm S-1000MM-S1SC20D SC SM 20 km/12.4 mi. 1490/1310 nm S-1000MM-S1SC40U SC SM 40 km/25 mi. 1310/1490 nm S-1000MM-S1SC40D SC SM 40 km/25 mi. 1490/1310 nm S-1000MM-S1SC80U SC SM 80 km/50 mi. 1510/1590 nm S-1000MM-S1SC80D SC SM 80 km/50 mi. 1590/1510 nm
Wavelength
Wavelength
Perle Gigabit Fiber to Fiber Media Installation Guide
2
Page 3
Fiber port 2 – MM2/SM2
(TX/RX)
Model Connector Mode Distance
S-1000MM-S1SC120U SC SM 120 km/74.6 mi. 1510/1590 nm S-1000MM-S1SC120D SC SM 120 km/74.6 mi. 1590/1510 nm
Visit Perle’s web site for the most up to date Installation guides, models and specifications:
Wavelength
http://www.perle.com/
Installation
The default switch setting (all switches in the UP position) will work for most installations. These are the steps required to configure the Perle Gigabit Fiber to Fiber media converter:
1. Set the DIP switch settings.(optional)
2. Install and connect fiber cable to MM1 port.
3. Install and connect fiber cable to MM2/SM2 port.
4. Power up the media converter.
DIP Switch Settings
The DIP switches are accessible through the opening in the side of the enclosure.
Note: Switch changes made when the product is powered up take effect immediately and will result in a link reset on both ports.
Perle Gigabit Fiber to Fiber Media Installation Guide
3
Page 4
Fiber Negotiation (Switch 1)
Switch Position Mode
Up (default) Auto Down Off
Auto: In this mode of operation the media converter will negotiate fiber parameters on both MM1 and MM2/SM2 (fiber ports). This will ensure the most optimal connection parameters will be in effect. If connecting to another Perle Media Converter, this parameter should be set to Auto.
Off: Fiber negotiation on both fiber ports will be disabled. Fiber Negotiation should only be turned off, if the fiber link partner does not support fiber link negotiations.
Link Mode (Switch 2)
Switch Position Mode
Up (default) Smart Link Pass-Through Mode Down Standard Mode
Smart Link Pass-Through: In this mode, the link state on one connection is directly reflected through the media converter to the other connection. If fiber link is lost on one of the connections, then the other fiber link will be brought down by the media converter.
Standard Mode: In this mode, the links can be brought up and down independently of each other. A loss of link on either fiber connection can occur without affecting the other fiber connection
Perle Gigabit Fiber to Fiber Media Installation Guide
4
Page 5
Fiber Fault Alert (Switch 3)
Switch Position Mode Up (default) Enabled Down Disabled
Enabled: If the media converter detects a loss of fiber signal on the fiber receiver, it will immediately disable its fiber transmitter signal on this port. This, in effect, notifies the fiber link partner that an error condition exists on the fiber connection.
If the remote media converter is set up for Fiber Fault Alert(FFA) Enabled and the local media converter is set up with Smart Link Pass-Through, a loss of fiber link on either the transmit or receive line will be passed through to the other fiber connection.
Disabled: The media converter will not monitor for fiber fault. Note: This feature is not required; if Fiber negotiation has been
enabled since link negotiation accomplishes the same thing. When Fiber Negotiation is enabled this switch is ignored.
Illustration of the FFA feature
Media Converter A Configuration
Link Mode–Standard Mode Fiber Fault Alert
Media Converter B Configuration
Link Mode–Smart Link Pass Through Mode Fiber Fault Alert
Perle Gigabit Fiber to Fiber Media Installation Guide
5
Page 6
Sequence of Events
1. Media Converter A loses fiber connection (RX) on MM2/SM2.
2. Media Converter A disables the transmitter (TX) MM2/SM2.
3. Media Converter B detects loss of fiber link on receiver RX – MM2/SM2.
4. Media Converter B turns off transmitter (TX) on MM1.
5. Media Converter A MM1 is not affected
Remote Loopback Fiber 1 (Switch 4)
Switch Position Mode Up (default) Disabled Down Enabled
Disabled: The loopback feature is disabled. This is the normal position for regular operation. The switch must be set to this position in order for data to pass through the media converter.
Enabled: This is a test mode. All data received on the receive (RX) fiber connection on port MM1 is looped back to the transmit (TX) fiber connection.
Note: Only one fiber interface can be in loopback at a time.
Remote Loopback Fiber 2 (Switch 5)
Switch Position Mode Up (default) Disabled Down Enabled
Disabled: The loopback feature is disabled. This is the normal position for regular operation. The switch must be set to this position in order for data to pass through the media converter.
Enabled: This is a test mode. All data received on the receive (RX) fiber connection on port MM/SM2 is looped back to the transmit (TX) fiber connection.
Note: Only one fiber interface can be in loopback at a time.
Perle Gigabit Fiber to Fiber Media Installation Guide
6
Page 7
Installing the Duplex Fiber Cable
1. Locate a 1000Base-X compliant duplex (2 strands) fiber cable with male connections.
2. Connect the fiber cables from one media converter to the other media converter/switch/fiber device ensuring that the RX and TX are reversed at the opposite end.
Installing the Simplex Fiber Cable
1. Locate a 1000Base-X compliant simplex (1 strand) fiber cable with male connections.
2. Connect the fiber cable from one media converter to the other media converter/switch/fiber device.
Powering up the Perle Media Converter
1. Connect the Perle supplied power adapter to the media converter.
2. Turn on the power at source.
3. Check that the PWR LED light is lit.
Perle Gigabit Fiber to Fiber Media Installation Guide
7
Page 8
Operation
Status LED
The Perle Gigabit Fiber to Fiber Media converters have three single colored status LEDs located on the front panel of the unit.
PWR - Power/Test
On: Power is on and the unit is in normal operation mode.
Blinking slowly: the unit is in loopback mode.
Blinking quickly: the unit has a hardware error.
LK1 – MM1 (Fiber Link) Activity
On: Fiber link present.
Blinking slowly: The fiber link has been taken down as a
result of Smart Link Pass-Through.
Blinking quickly: Fiber link present and receiving data.
Off: No fiber link present.
LK2 – MM2/SM2 (Fiber Link 2) Activity
On: Fiber link is present.
Blinking slowly: The fiber link has been taken down as a
result of Smart Link Pass-Through.
Blinking quickly: Fiber link present and receiving data.
Off: No fiber link present.
Perle Gigabit Fiber to Fiber Media Installation Guide
8
Page 9
Troubleshooting
General
Ensure power is supplied to the media converter – use of the Perle supplied power adapter is highly recommended.
Ensure both devices on either end of the fiber are compatible. If using a single fiber connection, ensure that you have both an Upstream (U) and Downstream (D) media converter.
Ensure all cabling is of the correct type and is in good operating condition.
For dual-stranded fiber connections, ensure the RX and TX has been reversed between the 2 media converters.
No connectivity
If unable to get full connectivity with all DIP switches in the UP position, this procedure is recommended for troubleshooting.
Method 1
1. Turn off Fiber Negotiation (SW1 Down) on both media converters. Set Link Mode to Standard. Leave all other switches in the UP position.
2. Connect the near end device to port MM1, the LK1 LED on each media converter should be lit to indicate good fiber connections. If the LK1 LED is not lit, then check the fiber cable and the attached device.
3. Repeat step 2 for port MM2/SM2.
4. Return units to desired configuration.
Method 2
Each fiber connection can also be verified by configuring the remote media converter for loopback mode. The link LEDs between the local and remote media converter should be lit. Data should pass through the local converter then over the fiber connection to the remote media converter.
Perle Gigabit Fiber to Fiber Media Installation Guide
9
Page 10
Technical Specifications
The following applies to all S-1000MM media converters:
Power Input/Consumption 12V DC /2.5 W Operating Temperature: 0°C - 50°C (32°F - 122°F) Storage Temperature: -25°C - 70°C (-13°F - 158°F) Operating Humidity: 5% to 90% non-condensing Storage Humidity: 5% to 95% non-condensing Operating Altitude: Up to 3,048 m (10,000 ft) Weight: 0.3 kg (0.66 lbs) MTBF: 432,138 hours (with power supply) 274,804 hours
Fiber Optic Specifications
Fiber port 1 – MM1
Model Mode
All models MM
Fiber port 2 – MM2/SM2
Model Mode
S-1000MM-M2xx05
S-1000MM-M2xx2
S-1000MM-S2xx10
S-1000MM-S2xx40
S-1000MM-S2xx70 SM
S-1000MM-S2xx120 SM
S-1000MM-S2xx160 SM
MM
MM
SM
SM
Wavelength
(nm)
TX: 850 RX: 850
Wavelength
(nm)
TX: 850 RX: 850
TX: 1310 RX: 1310
TX: 1310 RX:1310
TX: 1310 RX:1310
TX: 1550 RX:1550
TX: 1550 RX: 1550
TX: 1550 RX: 1550
TX Power
(dB)
Min: -9.5 Max: -4
TX Power (dB)
Min: -9.5 Max: -4
Min: -6 Max: -0
Min: -9.5 Max: -3
Min: -3 Max: 5
Min: -2 Max: 5
Min: 0 Max: 5
Min: 2 Max: 5
RX Power
(dB)
Min: -17 Max: -3
RX Power (dB)
Min: -17 Max: -3
Min: -17 Max: -0
Min: -20 Max: -3
Min: -23 Max: -3
Min: -23 Max: -3
Min: -32 Max: -9
Min: -34 Max: -9
Budget (dB)
7.5
Budget (dB)
7.5
11
10.5
20
21
32
32
Perle Gigabit Fiber to Fiber Media Installation Guide
10
Page 11
Model Mode
S-1000MM-S1SC10U SM
S-1000MM-S1SC10D SM
S-1000MM-S1SC20U SM
S-1000MM-S1SC20D SM
S-1000MM-S1SC40U SM
S-1000MM-S1SC40D SM
S-1000MM-S1SC80U SM
S-1000MM-S1SC80D SM
S-1000MM-S1SC120U SM
S-1000MM-S1SC120D SM
Wavelength
(nm)
TX: 1310 RX:1490
TX:1490 RX:1310
TX: 1310 RX:1490
TX:1490 RX:1310
TX: 1310 RX:1490
TX:1490 RX:1310
TX: 1510 RX:1590
TX:1590 RX:1510
TX: 1510 RX:1590
TX:1590 RX:1510
Fiber Cabling Requirements
TX Power (dB)
Min: -9 Max: -3
Min: -9 Max: -3
Min: -8 Max: -3
Min: -8 Max: -3
Min: -3 Max: 2
Min: -3 Max: 2
Min: -2 Max: 3
Min: -2 Max: 3
Min: -3 Max: 2
Min: -3 Max: 2
RX Power (dB)
Min: -20 Max: -3
Min: -20 Max: -3
Min: -22 Max: -3
Min: -22 Max: -3
Min: -23 Max: -3
Min: -23 Max: -3
Min: -26 Max: -3
Min: -26 Max: -3
Min: -34 Max: -9
Min: -34 Max: -9
Budget (dB)
11
11
14
14
20
20
24
24
31
31
MM: 50/125 microns
62.5/125 microns
SM: 9/125 microns Note: Please refer the product page on the Perle website for the
most up to date specifications.
http://www.perle.com/
Warranty / Registration
Perle’s standard Lifetime Warranty provides customers with return to factory repairs for Perle products that fail under the conditions of the warranty coverage. Details can be found at:
http://www.perle.com/support_services/warranty.shtml
Perle Gigabit Fiber to Fiber Media Installation Guide
11
Page 12
Compliance Information
FCC
This product has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this Guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense.
EN 55022 Class A
WARNING This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate measures.
EN 55024 Class A
Laser Safety – IEC 60825-1:2007
This product meets Class I Laser safety requirements per IEC-60825-1:2007 standard and complies with FDA/CDRH 21 CFR1040.10 and 21 CFR1040.11. WARNING: Visible and invisible laser radiation may be present when cables are not connected. Do not stare into the beam or view the beam directly with optical instruments. Failure to observe this warning could result in an eye injury or blindness. WARNING: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.
Contacting Technical Support
Contact information for the Perle Technical Assistance Center (PTAC) can be found at the link below. A Technical Support Query may be made via this web page.
www.perle.com/support_services/support_request.shtml
Copyright
© 2012 Perle Systems Limited All rights reserved. No part of this document may be reproduced or used in any form
without written permission from Perle Systems.
Perle Gigabit Fiber to Fiber Media Installation Guide