Air quality detector Instruction of AQ9600
www.perfect-prime.com
cs@perfect-prime.com
Please register product warranty on our website

IV. Function setting operation
VI. New air quality level
VIII. Product specification

AQ9600 has the function of measuring PM2.5, PM10, counting of dust particles,
temperature and humidity. The product is provided with high measurement
precision, stable performance and simple operation and convenient to carry. It is
suitable for indoor environment of family, office, inside of cars and natural
environment, etc.
1. The electronic sensors and microprocessors used on the product belong to
precision electronic device. The product must be kept away from water, fire,
inflammable oil and gas or sites with strong electromagnetic interference to
prevent influence on/damage to the device.
2. Don’t block; or avoid strong air or hot air blowing to the air inlet for air
sampling.
3. Please use dry cloth to wipe the instrument case. Don’t use damp cloth or
corrosive detergents.
4. Don’t dismantle and remodel the product without authorization.
1. Product structure and appearance description
Temperature and humidity
detection port
9V/500mA power supply and
charging interface
USB power supply interface

2. LCD display description
Schematic diagram of concentration grade
Display area of particle counting
Display area of particle weight calculation
3. Key function description

Key name and brief function
Power key [ ]: press to power on/off.
Operating measurement key [RUN]
(1) At the main interface, press to start data sampling.
(2) During the sampling period of 50s, other keys are disabled and cannot
operate. Only power key can function.
(1)
At the mode of historical record, press--confirm the page number of
(2)
At the mode of functional parameters, press—confirm to enter
(3)
At the mode of functional parameters, press—confirm the saved items
(1)
At the mode of historical record, press—select the unit’s place, ten's
place and hundred’s place of page number.
(2)
At the mode of functional parameters, press—select the functional
parameter items to be changed.
(1)
At the mode of historical record, used to increase by 1 (+1) and page
(2)
At the mode of functional parameters and at the change state: used to
increase by 1 (+1); switching unit and select “yes” or “No”.
(1) At the main interface, press in order to enter the historical record→
the functional parameter.
(2) At the mode of historical record, used to decrease by 1 (-1) and page
down by one page.
At the mode of functional parameters and at the change state: used to
decrease by1 ( -1); switching unit and select “yes” or “No”.
(1) At the mode of historical record and functional parameters,
press—back to the main interface.
(2) At the mode of historical record, when to change a parameter,
press—exit from the change.

IV. Function setting operation
Function setting operation
Page
number:
Unit’s
place/ten’s
place/hund
red’s place
Check historical record: at the main interface, press [▼]
key to enter historical record mode; press [ENTER] key and
the current page is selected. At the moment, press [▲] key
or [▼] key to go through the data. If you want to skip to
certain page directly, input the page number directly. Press
[SHIFT] key to select the unit’s place, ten’s place and
hundred’s place of the page number. Press [▲] key to
increase the value by 1 (+1) and press [▼] key to decrease
the value by 1 (-1).
Particle
unit:
piece/L,
ug/m
3
Change the particle unit: at the main interface, press [▼]
key twice to enter the functional parameter mode, press
[ENTER] key to enter the change state. Press [SHIFT] key to
select piece/L or ug/m3. At the moment, press [▲] key or
[▼] key to select your desirable unit and press [ENTER]
key to confirm. Press [BACK] key to return to the main
interface.
At the main interface, press [▼] key twice to enter the
functional parameter mode, press [ENTER] key to enter the
change state. Press [SHIFT] three times to select “No” in
the item of “changing time”. Press [▲] key or [▼] key to
select “Yes”. Press [ENTER] key to enter time change
interface. Press [SHIFT] key to select the items to be
changed. Press [▲] key to increase the value by 1 (+1) and
press [▼] key to decrease the value by 1 (-1). Press
[ENTER] to confirm. Press [BACK] key to return to the
main interface.
At the main interface, press [▼] key twice to enter the
functional parameter mode, and press [ENTER] key to enter
the change state. Press [SHIFT] key six times to select the
items to be changed in “temperature unit”. Press [▲] key
or [▼] key to select “degree centigrade” or “Fahrenheit
degree”. Press [ENTER] key to confirm. Press [BACK] key
to return to the main interface.
Restore
factory-set
value
At the main interface, press [▼] key twice to enter the
functional parameter mode, and press [ENTER] key to enter
the change state. Press [SHIFT] key seven times to select
the items to be changed in “Restore factory-set value”.
Press [▲] key or [▼] key to select “Yes”. Press [ENTER]
key to confirm. The screen displays “restoring factory set
value…”. After completion, press [BACK] key to return to
the main interface. (Users may also use the method to
delete data record).

The instrument should be placed in an open space before measurement to avoid blocking
VI. New air quality standard
Schematic diagram of
concentration grade
PM2.5 average standard
value in 24 hours.
1. The device is provided with the function of display of battery level. When the battery
2. When the adapter is inserted to charge the device, this should be done after
3. Charging should be made in a cool and ventilated room. If the surrounding
4.
Charging may also be made by connecting with a computer through USB. But such
of the sensors. Press the power key to switch on. Press [RUN] key at the main interface
and the instrument will enter the sampling state of 50 seconds. At the moment, do not
operate the instrument first. After completion of sampling, the measurement result will be
displayed on the display screen finally. Users may enter “functional parameter" interface
to set the particle unit so as to realize the switching of measurement mode (counting
mode/weighing mode).
Note: don’t carry out measurement at the time of charging in order to achieve a more
accurate measurement result.
level symbol is displayed as or , please charge in time.
powering off. It takes 2 to 3 hours to charge from empty battery to a full battery.
When it is fully charged, the battery symbol is . The charging should be stopped at
the moment.
temperature is too high, this may cause abnormal heat of the battery and circuit board
or even explosion.
method is not good for the instrument’s service life and suggested to be used seldom.

VIII. Product specification
Principle of PM2.5 Sensors
2 minutes(no key operation)
Technical specification of adapter
Input: AC100〜240V -50/60Hz;
output: 9VDC, 500mA
7.4V chargeable lithium battery
May provide power (unable to
download data)
LCD value display. Color backlight