Perfect Aire PMP50 User Manual

(50 PINT)
With Ejector Pump
USER MANUAL
Your Source for Home Comfort
FOR MODEL:
PMP50
Before using your dehumidifier, please read this manual carefully and keep it for future reference, along with your receipt.
CONTENTS
SAFETY PRECAUTIONS ..................................................................................... 2
IDENTIFICATION OF PARTS............................................................................... 3
DEHUMIDIFIER FEATURES ................................................................................ 4
OPERATING INSTRUCTIONS ............................................................................. 6
CARE AND MAINTENANCE .............................................................................. 10
TROUBLESHOOTING TIPS ............................................................................... 11
This manual provides the information needed for proper use and maintenance of this air conditioner. Basic preventative care can help extend the life of this unit. The “Troubleshooting Tips” section in this manual contains a chart with solutions to the most common problems. Referring to this section may save time and prevent the need for a service call in the event of a problem.
!
CAUTION
● Contact an authorized service technician for repair or maintenance of this unit.
● Contact an installer for installation of this unit if necessary.
The dehumidifier is not intended for use by young children without supervision. Young children should
be supervised to ensure that they do not play with the air conditioner.
● Disabled persons may require assistance with set up and usage.
● If the power cord is to be replaced, replacement work should be performed by authorized personnel only.
● Installation and repair work must be performed in accordance with the national wiring standards by authorized
personnel only.
NOTE: All the illustrations in this manual are for explanation purposes only. Unit purchased may be slightly different.
The design and specifications are subject to change without prior notice for product improvement. Contact
customer service for details.
ELECTRICAL INFORMATION
● The manufacturers nameplate is located on the rear panel of the unit and contains electrical and other technical
data specific to this unit.
● Be sure the unit is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
● Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the
proper receptacle.
● Ensure the receptacle is accessible after the unit installation.
● Do not use extension cords or an adaptor plugs with this unit. However, if it is necessary to use an extension cord, use an approved dehumidifier extension cord only (available at most local hardware stores).
● To avoid the possibility of personal injury, always disconnect the power supply to the unit before installing
and/or servicing.
1
SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by
the following indications:
! !
WARNING
CAUTION
!
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
Meanings of symbols used in this manual are:
Do not exceed the rating of the power outlet or connection device.
Otherwise, it may cause
electric shock or fire due to excess heat generation.
Do not modify power cord length or share the outlet with other appliances
It may cause electric shock or
fire due to heat generation.
!
Disconnect the power if strange sounds, smell, or
smoke comes from it.
It may cause fire and electric shock.
Do not operate or stop the unit by inserting or pulling plug directly from the wall.
It may cause electric shock or
fire due to heat generation.
Do not insert or pull out plug with wet hands.
It may cause electric shock.
You should never try to take apart or repair the unit by yourself.
It may cause failure of machine or electric shock.
WARNING
Do not damage or use an unspecified power cord.
It may cause electric shock
or fire.
Do not place the unit near a heat source.
Plastic parts may melt and cause a fire.
!
Before cleaning, turn off the power and unplug the unit.
It may cause electrical shock
or injury.
Always do this.Never do this.
!
Do not use the machine near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.
It may cause an explosion
or fire.
Do not drink or use the water drained from the unit.
It contains contaminants and could make you sick.
Do not take the water bucket out during operation.
It will cause bucket full code
to appear and can possibly
cause electric shock.
CAUTION
Do not cover the intake or exhaust openings with cloths or towels.
A lack of air flow can lead to
overheating and fire.
Never insert your finger or other foreign objects into grilles or openings. Take special care to warn children of these dangers.
It may cause electric shock or
failure of appliance.
!
Always insert the filters securely. Clean filter once every two weeks.
Operation without filters may cause failure.
!
Care should be taken when using the unit in a room with the following persons:
Infants, children, elderly people, and people not
sensitive to humidity.
Do not place heavy objects on the power cord; make sure that the cord is not compressed.
There is danger of fire or
electric shock.
!
If water enters the unit, turn the unit off and disconnect the power; contact a qualified service technician.
It may cause failure of
appliance or accident.
Do not use in areas where chemicals are handled.
This will cause deterioration of the unit due to the dissolving of chemicals and solvents in the air.
Do not climb up on or sit on the unit.
You may be injured if you fall or if the unit falls over.
Do not place flower vases or other water containers on top of the unit.
Water may spill inside the
unit, causing insulation failure and electrical shock or fire.
Do not use the unit in small spaces.
Lack of ventilation can
cause overheating and fire.
Do not put in places where water may splash onto the unit.
Water may enter the unit and
degrade the insulation. It may cause an electric shock or fire.
!
Place the unit on a level, sturdy section of the floor.
If the unit falls over, it may
cause water to spill and
damage belongings, or cause electrical shock or fire.
2
IDENTIFICATION OF PARTS
Front
Control panel
Air intake grille
Air outlet grille
Air filter (behind the grille)
Water bucket
Handle (both sides)
1
2
4
5
6
3
Fig. 1a - Front
Rear
Continuous drain hose outlet
Caster
Power cord and plug
Band (used only when storing the unit)
Pump drain hose outlet
4
1
2
3
Fig. 1b - Rear
5
NOTE:
Inside the bucket, on the left side, is an “arm”
mechanism that wobbles. This piece is called the “float.” DO NOT remove the foam piece that is
found in the cube-like part of the float. See Fig. 2. If the piece is removed, the bucket will overflow.
Accessories:
Drain Hose Adaptor A with Short Hose (1 pc ea)
for continous drainage operation
Located inside the bucket. Packaged on the side of the unit. Located in the upper corner of the
NOTE: For continuous drainage operation, a hose no longer than 6 ft is recommended. See page 12 for setup instructions and hose specifications if selecting continuous drainage option.
16 ft long Drain Hose (1 pc)
for pump drainage operation
Screw (2 pcs, 4x5/8”)
for drain hose adaptor, continuous drainage operation
packaging of this user manual.
Fig. 2 - Foam piece inside float mechanism.
DO NOT REMOVE
the foam.
NOTE: All the illustrations in this manual are for explanation purposes only. Unit purchased may be slightly different, but the operations and functions are the same.
3
DEHUMIDIFIER FEATURES
NOTE: The control panel of the unit you purchased may be slightly different based on the model.
Filter
Bucket full indicator light
Pump
Fig.3
Pump operation on indicator light
CONTROL PADS
When you push the button to change operation
modes, the unit will make a beep sound to indicate
that it is changing modes.
PUMP Pad
Press to activate the pump operation.
NOTE: Make sure the pump drain hose is
installed into the unit and the continuous drain hose is removed from the unit before the pump
operation is activated. When the bucket is full, the pump starts to work. Refer to the next pages for removing the collected water. Do not use this operation when the outdoor temperature is equal to or less than 32°F (0°C).
FILTER Pad
The check filter feature is a reminder to clean the
air filter for more efficient operation. The Filter
light (Clean Filter light) will illuminate after 250
hours of operation. To reset after cleaning the
filter, press the Filter pad and the light will go off.
FAN Pad
Controls the fan speed. Press to select either Turbo (High) or Normal fan speed. Set the fan
control to Turbo for maximum moisture removal.
When the humidity has been reduced and quiet operation is preferred, take the fan off of Turbo so the unit runs on Normal.
POWER Pad
Press to turn the dehumidifier on and off.
Filter
Full
Pump
Timer on/off indicator light
Clean filter indicator light
On Off
Timer
High fan indicator light
Turbo
Cont.
Fan
Continuous operation on indicator light
Auto defrost
Auto defrost operation on indicator light
DOWN – & UP + Pads
Humidity Set Control Pads
The humidity level can be set within a range of
35% RH (Relative Humidity) to 85% RH in 5% increments. For drier air, press the – pad and set to a lower percent value (%). For damper air, press
the + pad and set to a higher percent value (%).
Timer Set Control Pads
Use the Up/Down pads to set the Auto start and Auto stop time from 0.0 to 24 hours.
Continuous Operation
To run the unit in continuous mode, press the – pad until the display reads 35% RH. Then press
the – pad again until the display reads “CO” for continuous operation. To stop continuous
operation, press the + and set the desired % RH
set point level to resume normal operation.
NOTE: You cannot set a desired humidity while in continuous mode. Continuous mode means
the dehumidifier will run all the time and does not need a humidity setting.
TIMER Pad
Press to initiate the auto start and auto stop feature in conjunction with the + and – pads.
Display
Shows the set % humidity level from 35% to 85% or auto start/stop time (0−24) while setting, then shows the actual (5% accuracy) room % humidity level in a range of 30% RH to 90% RH.
4
Loading...
+ 9 hidden pages