Perfect Aire 3PAC6000, 3PAC8000, 3PAC12002, 3PAC12000, 3PAC10000 User Manual

0 (0)
6,000, 8,000, 10,000 & 12,000 BTU
WINDOW AIR CONDITIONER
USER MANUAL
Your Source for Home Comfort
FOR MODELS:
3PAC6000 3PAC8000 3PAC10000 3PAC12000 3PAC12002
Before using your window air conditioner, please read this manual carefully and keep it for future reference, along with your receipt.
CONTENTSCONTENTS
SAFETY PRECAUTIONS ................................................................................. 2–3
IMPORTANT SAFETY INSTRUCTIONS ...............................................................4
NORMAL SOUNDS .............................................................................................. 5
AIR CONDITIONER FEATURES......................................................................5–9
INSTALLATION INSTRUCTIONS .................................................................10–13
CARE AND CLEANING.......................................................................................14
TROUBLESHOOTING TIPS ............................................................................... 15
This manual provides the information needed for proper use and maintenance of this air conditioner. Basic preventative care can help extend the life of this unit. The “Troubleshooting Tips” section in this manual contains a chart with solutions to the most common problems. Referring to this section may save time and prevent the need for a service call in the event of a problem.
!
CAUTION
● Contact an authorized service technician for repair or maintenance of this unit.
● Contact an installer for installation of this unit if necessary.
The air conditioner is not intended for use by young children without supervision.
Young children should be supervised to ensure that they do not play with the air conditioner.
● Disabled persons may require assistance with set up.
● If the power cord is to be replaced, replacement work should be performed by authorized
personnel only.
● Installation and repair work must be performed in accordance with the national wiring standards by authorized personnel only.
● Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
NOTE: All the illustrations in this manual are for explanation purposes only. Unit purchased may be slightly different.
The design and specifications are subject to change without prior notice for product improvement. Contact customer service for details.
1
SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions
must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.
! !
!
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
Meanings of symbols used in this manual are as shown below.
!
!
!
!
Plug in power plug properly.
Failure to do so may cause
electric shock or fire due to
excess heat generation
Do not modify power cord length or share the outlet with other appliances.
Doing so may cause electric
!
shock or fire due to heat
generation.
Always ensure effective grounding.
Never do this.
Always do this.
! !
Do not operate or stop the unit by inserting or pulling out the power plug directly from the wall.
Doing so may cause electric shock or fire due to heat generation.
.
Do not operate with wet hands or in damp environment.
Doing so may cause electric shock.
Do not allow water to run into electric parts.
WARNIN
G
Do not use a damaged power cord.
Doing so may cause electric shock
or fire. If the power cord is
damaged, it must be replaced by the manufacturer or an authorized service center or a similarly qualified person in order to avoid a hazard.
Do not direct airflow directly at room occupants.
This could cause health issues.
!!
Always install circuit breaker and a dedicated power circuit.
Incorrect grounding may cause
!
electric shock.
!
Always unplug the unit if strange sounds, smell or smoke comes from the unit.
!
Failure to do so may cause fire
and electric shock.
Do not use firearms near unit.
Doing so may cause fire.
!
!
Ventilate room before operating air conditioner if there is a gas leak from another appliance such as a stove.
Failure to do so may cause explosion,
fire and burns.
Doing so may cause failure of machine or electric shock.
Do not use the socket if it is loose or damaged.
Doing so may cause fire and electric shock.
Do not use the power cord close to heating appliances.
Doing so may cause fire and electric shock.
Incorrect installation may cause fire
and electric shock.
Do not open the unit during operation.
Doing so may cause electric shock.
Do not disassemble, modify, or drill holes into the air conditioner.
Doing so may cause failure and electric shock.
Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.
Doing so may cause an explosion or fire.
2
SAFETY PRECAUTIONS (CONTINUED)
CAUTION
!
When removing air filter, do not touch metal parts of the unit.
Doing so may cause an injury.
!
Unit and circuit breaker/fuse must be switched OFF when cleaning.
Cleaning unit when power is ON
may cause fire and electric shock
and may cause an injury.
Stop operation and close the window in severe storms or hurricanes.
Operation with windows open may cause moisture to enter the room.
Do not place obstacles around air-inlets or inside of air-outlet.
Obstacles may cause appliance failure or accident.
.
Do not clean with water.
Water may enter the unit and degrade the insulation causing an
electric shock.
Do not put a pet or house plant where it will be exposed to direct air flow.
This could injure the pet or plant.
!! !
Hold the plug by the head of the power plug when taking it out.
Failure to do so may cause electric
shock and damage.
!
Periodically check installation bracket for damage.
.
Prolonged exposure to outdoor elements may cause damage to
installation bracket causing unit to
fall.
!
Ensure proper ventilation especially in rooms with a stove or other appliances.
Failure to do so may result in an oxygen shortage.
!
Use only as intended.
This unit is NOT intended to
preserve precision devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc.
If unit will not be used for a long period of time, turn OFF main power switch.
Leaving power on may cause unit failure or fire.
!
Always insert the filters securely. Clean filter AT LEAST once every two weeks.
Operation without secured filters may cause failure. A dirty filter can cause the unit to not run
efficiently.
!
Use only a soft cloth to clean the unit.
Cleaners or detergents may change the color or scratch the surface of the unit.
Do not place heavy objects on the power cord and always ensure that the cord is not compressed.
There is danger of fire or electric shock.
!
Use caution when unpacking and installing.
Sharp edges could cause injury.
NEVER drink water drained from air conditioner.
Water from unit contains contaminants and could cause illness.
!
If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified serviced technician.
There is danger of electric shock.
3
IMPORTANT SAFETY INSTRUCTIONS
NOTE
this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section "Operation
of Current Device" (below) for details.
In the event that the power supply cord is damaged, it MUST be replaced by
an authorized repairman.
Power supply cord with 3-prong grounding plug and current detection device
The power supply cord with
DO NOT, under any circumstances, cut, remove, or bypass grounding prong.
WARNING!
DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
Avoid fire hazard or electric shock. DO NOT use an extension cord or an adaptor plug. DO NOT remove any prong from the power cord.
WARNING!
Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the
side of the cabinet and behind the grille.
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If
the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician
install the proper receptacle. Ensure the receptacle is accessible after the unit installation.
Do not run air conditioner without side protective cover in place. This could
result in mechanical damage within the air conditioner.
Do not use an extension cord or an adaptor plug.
For Your Safety
Electrical Information
r.
WARNING!
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions,
including the following:
If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first. If the window is a triple-track type with a screen panel included, remove the screen completely before installation.
Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual. Save this manual for possible future use in removing or installing this unit.
When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
Prevent Accidents
Operation of Current Device
The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following:
1. Plug in the air conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST
button. The RESET button will click as it pops out.
3. Press the RESET button; again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit.
(On some products this is also indicated by a light on the plug head.)
NOTES:
Do not use this device to turn the unit on or off. Always make sure the RESET button is pushed in for correct operation.
The power supply must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset. If power supply cord is damaged, it cannot be repaired. Please call customer service to assist with replacement.
NOTE: This air conditioner is designed to be operated under conditions as follows:
Plug in & press RESET
TEST
RESET
NOTE: Some plugs have buttons on the top.
Cooling operation
Performance may be reduced outside of these operating temperatures.
Outdoor temp: 18-43°C/64-109°F (18-52°C/64-125°F for special tropical models)
Indoor temp: 17-32°C/62-90°F
4
NORMAL SOUNDS
High Pitched Chatter
High efficiency compressors may have a high pitched chatter during the cooling cycle.
Vibration
Unit may vibrate and make noise because of poor wall or window construction or incorrect installation.
This DOES NOT indicate a
defective unit.
Sound of Rushing Air
At the front of the unit, the sound of rushing air being moved by the fan may be heard.
Pinging or Switching
Droplets of water hitting condenser
during normal operation may cause “pinging” or “switching” sounds.
Gurgle/Hiss
“Gurgling” or “hissing” noise may be heard due to refrigerant passing through evaporator during normal operation.
NOTE: All of the pictures in this manual are for explanatory purposes only. The actual shape/look of the air conditioner purchased may be slightly different, but the operations and functions are similar.
AIR CONDITIONER FEATURES
ELECTRONIC CONTROL OPERATING INSTRUCTIONS
Thoroughly familiarize yourself with the control panel as shown below and all of its functions. Afterwards,
follow the symbol for the functions you desire BEFORE operating the unit. This unit can be controlled by the unit control or with the remote control.
DISPLAYS TEMPERATURE OR TIME OR ERROR CODES
ADJUSTS TEMPERATURE OR TIME
FOLLOW ME INDICATOR
SETS MODE
SLEEP MODE
ACTIVATES TIMER
TURNS UNIT ON OR OFF
ADJUSTS TEMPERATURE OR TIME
SETS FAN SPEED
ENERGY SAVER MODE
CHECK FILTER RESET BUTTON
REMOTE SIGNAL RECEPTOR
Auto
Low
Med
High
Energy Saver
Check Filter
TEMP/TIMER
Follow Me
Fan
On
Timer
Auto
Cool
Dry
Fan
Mode
O
Sleep
UNIT CONTROL
5