Fan Motors Permanently Lubricated: All units
have two fan motors for quiet operation and maximum
operating efficiency.
Motors are permanently lubricated to reduce
maintenance and completely enclosed to keep dirt
and water out of the motor windings.
Indoor Fan Speed Selections LOW/HIGH: Unit may
be operated in low fan speed or high fan speed. Some
speeds may not be available based on unit capacities.
Rotary Compressor: Smoother operation for quiet,
dependable service and high efficiency.
Indoor Coil Frost Control: Prevents indoor coil from
freezing. Frost can form on the indoor coil when the unit
is operated in cooling when the outdoor temperature
is low. The unit automatically shuts the compressor off
until the indoor coil temperature warms to the point.
UNIT ACCESSORIES
This unit is designed for through-the-wall installation in
new or existing buildings. To complete the installation
of this PTAC, an insulated wall sleeve and an outdoor
grille (either the stamped aluminum grille, or the
architectural grille ) are required.
The chassis and the cabinet front are shipped in one
carton. Optional accessories to complete a particular
installation are the following:
OPTIONAL ACCESSORIES
• Power switch Kit
• Wall Sleeve Kit
• Key Lock Kit • Drain Kit
•
Filter Kit • Hard Wire Kit
• Wire Harness Kit • Architectural Grille Kit
• Stamped Louver
Kit • LCDI Power Cord
• Wireless IR
Antenna • Wireless IR
Thermostat
• Electric
And Non Electric Sub Base Kit
• IR REMOTE CONTROLLER
NOTE: Consu lt sales litera ture f or the app ropri ate
voltage and amperage selections, if appl icabl e.
-3-
R LS GH B Y W GL C
WALL MOUNTED THERMOSTAT INTERFACE
DIP
Switches
Function Description
ON - When the unit is connected to the power supply, and
the room temperature is lower
than 10°C/50°F for 3 min., the
unit will start heating automatically no matter the mode. Only
when the room temperature
reaches 13°C/55°F will heating stop. (Only for units with
heat pump)
5 Auto Heating
6
Electric Power
ON - Once the power is On
the unit will run the pervious
settings.
off Memory
Fan for Heating ON - Enables the fan to run
continuously when heating.
Default setting is cycling fan in
heating mode.
7
Continuosuly
(CON)/ Cycle
(CYC)
Fan for Cooling ON - Enables the fan to cycle
when cooling. Default setting
is continuous fan in cooling
mode.
8
Cycle (CYC)/
Continuosuly
(CON)
DIP
Switches
Function Description
1 Reserved
2 Reserved
3 Reserved
4
Heating ON - Heat pump to be priority
OFF - Electric Heat to be priorityPriority
Special Control Functions for DIP Switches:
Fig.9
WARNING
Before service, you must disconnect the power cord to
avoid electric shock! Forbid to reprogram DIP switches
NO.1 and No. 3, otherwise the unit will fall into wrong
control or even cause fire! After changing the DIP switch,
power the unit on again; the new function will be activated.
WARNING
HIGH VOLTAGE
DISC ONNE CT A LL P OWER BE FORE SER VI CING O R
INSTALLING THIS UNIT. M ULTIPLE POWER SOURCES MAY
BE PRESENT, FAILURE TO DO SO MAY CAUSE PROPERTY
DAMAGE, PERSONAL INJURY OR DEATH.
: