Perfect Aire 1PAMSHH series, 2PAMSH series, 2PAMSHQC series, 2PAMSDH series, 2PAMSCH series User Manual

FOR SERIES:
2PAMSH
2PAMSCH
2PAMSDH
2PAMSHQC
USER MANUAL
REMOTE CONTROL
DUCTLESS MINI-SPLIT SYSTEM
Before using your air conditioner, please read this manual carefully and keep it for future reference, along with your receipt.
CONTENTS
Remote Control Specications.................................... 1
Operation of Buttons ................................................... 1
Indicators on the LCD ................................................. 3
How to Use the Buttons .............................................. 4
Auto Operation .......................................... 4
Cooling/Heating/Fan Operation ................4
Dehumidifying Operation ..........................5
Timer Operation ........................................5
Handling the Remote Control ...................................... 9
NOTE:
• Button design is based on standard model. Your remote may dier slightly based on actual model purchased.
• All functions described herein are accomplished with the indoor unit. If your unit does not have a certain feature or option there will be no corresponding function when that specic button is pressed.
• If there are dierences between the Remote Control Manual and Indoor/Outdoor User Manual on function descriptions, the description in the Indoor/Outdoor User Manual shall prevail.
1
REMOTE CONTROL SPECIFICATIONS
OPERATION OF BUTTONS
PERFECT AIRE MODELS
• Hyper Heat High Wall Ductless Mini-Split Units 1PAMSHH Series (Single-Zone)
• High Wall Ductless Mini-Split Units 2PAMSH Series (Single-Zone & Multi-Zone)
• Cassette Indoor Units 2PAMSCH Series (Multi-Zone)
• Ducted Indoor Units 2PAMSDH Series (Multi-Zone)
• Quick Connect Ductless Mini-Split Units 2PAMSHQC Series (Single-Zone)
RATED VOLTAGE: 30.V (AAA Dry batteries R03/LR03 x 2)
SIGNAL RECEIVING RANGE: 26 ft (8m)
ENVIRONMENT: 2 3 ° F – 14 0 ° F
1. ON/OFF Button
This button turns the air conditioner ON and OFF.
2. MODE Button
Press this button to select the air conditioner mode in the following sequence:
AUTO COOL DRY HEAT FAN
3. FAN Button
Used to select the fan speed as shown:
AUTO LOW MED HIGH
4. SLEEP Button
Activate/Disable Sleep function. Maintains a comfortable temperature and saves energy. This function is available on COOL, HEAT, or AUTO mode only. For more information, see “Sleep Operation” in the Indoor/Outdoor User Manual. NOTE: While the unit is running in SLEEP mode, if MODE, FAN SPEED, or ON/OFF button is pressed, the SLEEP function will be canceled.
5. TURBO Button
Activate/Disable Turbo function. Turbo function allows for the unit to reach the preset temperature for cooling or heating operation in the shortest time. (If the indoor unit does not support this function, there is no corresponding operation when this button is pressed.)
1
7
8
9
10 11 12 13 14
2
3
4
5 6
2
6. SELF CLEAN Button
Activate/Disable Self Clean function. Under SELF CLEAN mode, the air conditioner will automatically clan and dry the Evaporator and keep it fresh for the next operation.
7. UP Button (
)
Push this button to increase the indoor temperature setting in 1°F increments to 86°F.
DOWN Button ( )
Push this button to decrease the indoor temperature setting in 1°F increments to 62°F.
NOTE: Temperature control is not available in FAN mode.
NOTE: Press and hold UP and DOWN
buttons together for 3 seconds to alternate the temperature display between the °F and °C scale.
8. SILENCE/FP Button
• Activate/Disable Silence function: Press button for more than 2 seconds and the FP button will be activated. Pressing again for 2 seconds disables the FP function.
• When the Silence function is activated, the compressor will operate at low frequency and the indoor unit will blow at a faint breeze, which will reduce noise to the lowest level, creating a quiet and comfortable room. Due to low frequency operation of compressor, it may result in insucient cooling and heating output.
• The FP function can only be activated during the heating operation (only when the setting mode is HEAT). The unit will operate at a setting temperature of 46°F. The display window of indoor unit will display ‘FP’. Pressing the ON/OFF, SLEEP, FP, MODE, FAN SPEED, UP or DOWN while operating will cancel the FP function.
9. TIMER ON Button
Press the button to initiate the auto-on time sequence. Each press of the button will increase the auto-time setting in 30 minute increments. When the setting time displays 10.0, each press of the button will increase the auto-time setting in 60 minute increments. To cancel the auto­time program, simply adjust the auto-on
time to 0.0.
10. TIMER OFF Button
Press the button to initiate the auto-o time sequence. Each press of the button
will
increase the auto-time setting in 30 minute increments. When the setting time displays 10.0, each press of the button will increase the auto-time setting in 60 minute increments. To cancel the auto­time program, simply adjust the auto-on
time to 0.0.
11. SWING Button
Used to stop or start horizontal louver auto swing feature.
12. DIRECT Button
Used to change the louver movement and set the desired up/down air ow direction. The louver changes 6° in angle with each press of the button.
13. FOLLOW ME Button
Push this button to initiate the Follow Me feature. The remote will display actual temperature at its location. The remote control will send this signal to the air conditioner in 3 minute intervals until the FOLLOW ME button is pressed again. The air conditioner will cancel the Follow Me feature automatically if it does not receive the signal during any 7 minute interval.
14. LED Button
Disable/Activate indoor screen display. When pushing this button, the indoor unit screen display is cleared. Press the button again to light the display.