Perfect Aire 1PAMSH22-15 User Manual

This manual carefully and keep it for future reference along with your receipt.
INVERTER SINGLE ZONE SPLIT-TYPE AIR CONDITIONER
Read ThisManual
This manual provides the information needed for proper use and maintenance of this air conditioner. Basic preventive care can help extend the life of this unit. The “Troubleshooting Tips” contains a chart with solutions to the most common problems. Referring to this section may save time and prevent the need for a service call in the event of a problem.
CONTENTS
SAFETY PRECAUTIONS
Warning ..................................................................................................................................2
Caution ...................................................................................................................................3
OPERATINGINSTRUCTIONS
Parts names ...........................................................................................................................4
Special functions .....................................................................................................................5
Operating temperature.............................................................................................................6
Manual operation ....................................................................................................................6
Airflow direction control ..........................................................................................................7
How the air conditioner works ...............................................................................................8
CARE AND MAINTENANCE
Care and maintenance ..........................................................................................................9
OPERATION TIPS
Operation tips .......................................................................................................................11
TROUBLESHOOTING TIPS
Troubleshooting tips .............................................................................................................13
CAUTION
Contact the authorized installer for installation of this unit. Contact an authorized service technician for repair or maintenance of this unit. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by persons responsible for their safety. Young children should be supervised to ensure that they do not play with the air conditioner.
Installation work must be performed in accordance with national or local wiring standards by authorized personnel only.
1
SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The seriousness is classifiedbythe following indications.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
Meanings of symbols used in this manual are as shown below.
Never do this.
Always do this.
WARNING
!
Always ensure effective grounding.
No grounding may cause electric shock.
!
Disconnect the power if strange sounds, smell, or smoke comes from it.
It may cause fire and electric shock.
!
Use the correctly rated breaker or fuse.
Do not operate or stop the unit by switching on or off the power.
It may cause electric shock or fire due to heat generation.
Do not operate with wet hands or in damp environment.
It may cause electric shock.
Do not allow water to run into electric parts.
Do not direct airflow direc­tly at room occupants .
This could cause health issues.
!
Always install circuit breaker and a dedicated power circuit.
No installation may cause
fire and electric shock.
Do not open the unit during operation.
There is risk of fire or electric shock.
!
Ventilate room before operating air conditioner if there is a gas leakage from anotherappliance.
It may cause explosion, fire and burns.
It may cause failure of machine or electric shock.
Never drink water drained from air conditioner.
It contains contaminants and could make you sick.
2
It may cause electric shock.
Do not disassemble or modify unit.
It may cause failure and electric shock.
SAFETY PRECAUTIONS
When the air filter is to be removed, do not touch the metal parts of the unit.
CAUTION
Do not put objects like thin rods into the panel of blower and suction side.
!
Ensure proper ventalation, especially in rooms with a stove or other appliance
It may cause an injury.
!
Unit and circuit breaker/fuse must be switched off when cleaning.
Do not clean unit when power is on as it may cause fire, electric shock or injury.
Use only a soft cloth to clean the unit.
Cleaners or detergents may change the color or scratch the surface of the unit.
Do not clean the indoor unit with water. Use only soft cloth or slightly damp cloth.
.
Water may enter the unit and degrade the insulation. It may cause an electric shock.
The high-speed fan inside may cause danger.
Do not put a pet or house plant where it will be exposed to direct air flow.
This could injure the pet or plant.
Do not place obstacles around air-inlets or inside of air-outlet.
It may cause failure of appliance or accident.
!
Periodically check the outdoor installation bracket for damage as necessary.
Prolonged exposure to outdoor elements may cause damage to installation bracket causing unit to fall.
An oxygen shortage may occur.
Use only as intended.
Do not use this air cond­itioner to preserve preci­sion devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc.
!
Turn off the main power switch when not using the unit for a long time.
Not doing this may cause failure of product or fire.
!
Always insert the filters securely. Clean filter once every two weeks.
Operation without filters may cause failure.
!
Use caution when unpacking and installing. Sharp edges could cause injury.
3
If water enters the
!
unit, turn the unit off and disconnect the power , contact a
qualified service
technician.
OPERATINGINSTRUCTIONS
4
2
5
Air inlet
Air outlet
1
(side)
3
7
6
Airinlet(
rear)
Signal receiver
Indoor unit
1. Front panel
2. Air inlet
3. Airfilter
4. Air outlet
5. Horizontal air flowgrill
6. Vertical air flow louver (inside)
8
7. Display panel
NOTE: Theactual shape of the indoor unit you purchased maybeslightly different on front panel and display window.
Outdoor unit
8. Connecting pipe
9. Connecting cable
9
10
10. Stop valve
NOTE:
Allthe pictures in this manual are for explanation purposes only. Your air conditioner may be slightlydifferent. The actual shape shall prevail.
A
Signal receiver
B
ModelNameAnd Dimensions
MODEL
9000 Btu
12000 Btu
WIDTH (mm)
26.8" (680 mm)
30.2" (770 mm)
VLED Display Window
OPERATION indication lamp
This lamp illuminates when the air conditioner is in operation.
TIMERindicationlamp
Lightsup during Timer operation.
DEFROST i
ndication lamp
(Enabled on cooling & heating models only):
Lightsup when the air conditioner starts
defrosting automatically or when the warm air controlfeatureisactivated in heating operation.
Temperatureindicator
Displaysthe temperaturesettings when the air conditioner is operational. Displaysthe malfunction code.
HEIGHT (mm) DEPTH (mm)
10.1" (255 mm)
10.1" (255 mm)
7.1" (180 mm)
7.5" (188 mm)
18000 Btu
22000 Btu
35.7" (905 mm)
40.6" (1030 mm)
10.8" (275 mm)
12.5" (315 mm)
4
7.8" (198 mm)
8.7" (220 mm)
Loading...