1. Introduction
To all residents of the European Union Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, do not install or use it and contact your dealer.
2. Safety Instructions
Warning! Visible laser radiation. Do not stare into the beam as
eye damage may occur. This device contains a
class 2 laser.
Output power does not exceed 1 mW, wavelength 650 nm.
Never point the laser beam at a person or animal. Never point the laser beam at reflective surfaces. Never look at the laser beam using an optical instrument, such as binoculars or a microscope.
Keep this device away from children and unauthorized users.
Keep this device away from rain, moisture, splashing and dripping liquids. Never put objects filled with liquids on top of or close to the device.
3. General Guidelines
Refer to the Velleman® Service and Quality Warranty on the last pages of this manual.
· Keep this device away from dust and extreme temperatures.
· Protect this device from shocks and abuse. Avoid brute force when
operating the device.
· Familiarise yourself with the functions of the device before actually using it.
· All modifications of the device are forbidden for safety reasons. Damage caused by user modifications to the device is not covered by the warranty.
Page 4
EEM100
V. 01 – 07/05/2015 4 ©Velleman nv
· Only use the device for its intended purpose. Using the device in an unauthorised way will void the warranty.
· Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems.
· Do not switch the device on immediately after it has been exposed to changes in temperature. Protect the device against damage by leaving it switched off until it has reached room temperature.
· Readings may be affected if the unit is operated within a radio frequency electromagnetic field, but the performance of the instrument will not be permanently affected.
· Use the original packaging if the device is to be transported.
· Keep this manual for future reference.
4. Features
· laser sight technology
· temperature readout in °C or °F
· large LCD display with white backlight
· display hold
· auto power-off function (20 seconds)
5. Overview
Refer to the illustrations on page 2 of this manual.
A
laser beam
D measurement trigger
B
IR sensor
E battery compartment
C
LCD display
F °C/°F mode button
Display
1
emissivity
5 temperature unit
2
backlight
6 current reading
3
laser
7 measurement
4
battery
8
data hold
6. Battery
This device is battery-operated, using 1x 9 V battery. Replace it when the battery-low icon appears.
To replace the battery, proceed as follows:
1. Wait until the device powers off automatically (about 7 s).
A malfunction may occur if you replace the batteries while the device is on.
2. Open the battery compartment [E].
Page 5
EEM100
V. 01 – 07/05/2015 5 ©Velleman nv
3. Replace the battery with a new 9 V battery.
4. Close the battery compartment.
Warning: Do not puncture batteries or throw them in fire as they
may explode. Do not attempt to recharge non
-rechargeable batteries (alkaline). Dispose of batteries in accordance with local regulations. Keep batteries away from children.
7. Operation
1. Aim the IR sensor [B] at the target and press the measurement
trigger [D] to display the target’s surface temperature. A red laser spot appears on the target during measurement.
2. The distance-to-target ratio is 12:1. This means that, for example, at
12 cm, the target must be larger than 1 cm to get a proper measurement. Make sure the target area is within this field of view.
3. The device can measure temperatures in °C or °F. Press the mode key [F] while the device is on to switch between measurement units. The corresponding symbol (°C or °F) appears on the display.
4. When you release the measurement trigger [D], the hold mode is automatically activated: the last measurement value remains on the display until you press the measurement key again, or until the device shuts off automatically (after approx. 7 seconds).
5. Note that the display is always on, while the laser is only on during measurement.
Remarks: The temperature
·
of a shiny or polished metal surface
·
through a transparent surface such as glass
·
of an object covered with frost, grime, oil
cannot be measured.
8. Cleaning and Maintenance
· The IR sensor [B] is the most delicate part of the device and it shall be
kept clean at all times. To do this, only use a soft cloth or cotton bud with a little water or medical alcohol.
· Allow the lens to fully dry before using the device.
· Wipe the other parts of the device regularly with a moist, lint-free cloth.
Do not use alcohol or solvents.
· Do not submerge the device in water or any other liquid.
· There are no user-serviceable parts. Contact your dealer for spare parts
if necessary.
· The device shall be stored between –20° C and +65° C (4° F to
+149° F).
Page 6
EEM100
V. 01 – 07/05/2015 6 ©Velleman nv
9. Technical Specifications
measurement range
-50° C to 330° C (-58° F to 626° F)
target ratio
12:1
emissivity
0.95 fixed
operating temperature
0-50° C (32-122° F)
storage temperature
-20° C to 60° C (-4° F to 140° F)
accuracy
-50° C~0° C / -58° F~32° F
± 4° C / 7° F
0° C~330° C / 32° F ~ 626° F
± 2% ± 2° C / 4° F
resolution
0.1° C / 0.1° F
response time
< 500 ms
power supply
1 x 9 V (included)
dimensions
134 x 88.5 x 36 mm
weight (with battery)
± 130 g
Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulting from (incorrect) use of this device. For more info concerning this product and the latest version of this manual, please visit our website www.velleman.eu. The information in this manual is subject to change without prior notice.