2 TECHNICAL SPECIFICATIONS
Rated operating voltage
1
Operating voltage limits .................................................................................. 10.8–14VDC
......................................................................................... 12VDC
Consumption current ...................................................................................... max. 150 mA
Power consumption .............................................................................................. max. 2 W
Card reading distance at the rated operating voltage for different card types:
HID ProxCard II cards ................................................................................. min. 6 cm
EM-Marin cards ........................................................................................... min. 7 cm
Controller connection interface
2
Distance between reader and controller ............................................................. max. 40 m
............................................................... RS-485, Wiegand
Reader post weight .............................................................................................. max. 5 kg
Reader post dimensions (see Fig. 1) .................................................... 1025×107×107 mm
Mean lifetime ........................................................................................................... 8 years
Electric shock protection class ........................................... III under GOST R IEC 335-1-94
3 DELIVERY SET
Reader post ....................................................................................................................... 1
Mounting base ................................................................................................................... 1
S2 allen key ....................................................................................................................... 1
Package ............................................................................................................................. 1
Certificate and Operation Manual ...................................................................................... 1
Additional mounting tools:
The following equipment can be supplied optionally on request:
PFG IR 8-20 anchor («SORMAT», Finland) ...................................................................... 4
1
As a power supply it is recommended to use DC source with linear voltage stabilization and
output pulsation amplitude max. 50 mV.
2
Depends on position of switch №1 SA1.