Pepperl Fuchs VLM350-F280-2E2-1000 Data Sheet

Laser light sensor VLM350-F280-2E2-1000
READY
MATCH 1/2
MATCH 3/4
RESULT
DIAGNOSE
TRIGGER
POWER
TEACH
Function
The SmartRunner Matcher compares current height profiles with a previously taught-in height profile. The Matcher is based on innovative SmartRunner technology and combines the light section method for detecting height profiles with a 2-D vision sensor. The light section method involves projecting a laser line onto an object. This is then detected by a camera at a specific angle. A height profile is then created using the triangulation principle. This innovative laser technology provides reliable measurements on different surfaces.
Indicating / Operating means
Model Number
VLM350-F280-2E2-1000
Laser light sensor for profile matching
Features
• Laser class 1, eyesafe
• Data Matrix control codes for parame­terization
Laserlabel
1
2
3
READY
MATCH 3/4
RESULT
MATCH 1/2
4
Electrical connection
5
6
7
1
Pin Signal
1 IN Trigger 2 +UB 3 Data+ RS-485 4 Data- RS-485 5 Teach 6 Good 7 GND 8 Bad
8
1 Ready 2 Match 3/4 3 Result 4 Match 1/2 5 Diagnose 6 Power 7 Teach
DIAGNOSE
POWER
TEACH
TRIGGER
5
6
7
8
8 Trigger
4
3
2
green/red green/yellow green/red green/yellow red green yellow yellow
Release date: 2017-10-05 14:01 Date of issue: 2018-03-06 284586-100001_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Technical data
General specifications
Measurement range X = 40 ... 160 mm ; Z = 60 ... 350 mm Light source laser diode Light type red laser + Integrated LED lightning red 650 nm Laser nominal ratings
Note VISIBLE LASER RADIATION , DO NOT STARE INTO BEAM
Laser class 1 Wave len gth Measurement laser: 660 nm Pulse length Measurement laser: 0.5 ms Maximum optical power output Measurement laser: 15 mW Laser monitoring The safety system switches off the laser when the laser current
Scan rate 10 s Resolution X > 0.44 mm ; Z > 0.4 mm
Functional safety related parameters
MTTFd 20 a Mission Time (TM) 10 a Diagnostic Coverage (DC) 0 %
Indicators/operating means
Operation indicator LED green Diagnostics indicator LED yellow / red Function indicator Trigger: LED yellow ; object detected : LED red / green Control elements 2 push-buttons
Electrical specifications
Operating voltage UB24 V ± 20 % , PELV No-load supply current I Power consumption P0max. 6 W , Outputs without load
DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS
is too high
-1
at 60 mm read distance
max. 250 mA
0
1
VLM350-F280-2E2-1000Laser light sensor
Interface
Interface type RS 485 interface Physical Switchable terminal resistor Protocol binary code Transfer rate 38400 ... 230400 Bit/s
Input
Input voltage 24 V Number/Type External triggering + 1 Input Switching threshold low: < 2.5 V, high: > 8 V
Output
Number/Type 2 digital outputs Switching type PNP Switching voltage 24 V Switching current 150 mA each output
Ambient conditions
Operating temperature -20 ... 45 °C (-4 ... 113 °F) , (noncondensing; prevent icing on
Storage temperature -20 ... 70 °C (-4 ... 158 °F)
Mechanical specifications
Degree of protection IP67 Connection 8-pin, M12 x 1 connector ( supply + RS485 + Inputs/Outputs ) ;
Material
Housing PC/ABS
Optical face Plastic pane Mass approx. 125 g Tightening torque, fastening screws 2 Nm
General information
Note Security Instructions:
Compliance with standards and directi­ves
Standard conformity
Noise immunity EN 61000-6-2:2005
Emitted interference EN 61000-6-4:2007/A1:2011
Degree of protection EN 60529
Shock and impact resistance EN 60068-2-27:2009
Laser class IEC 60825-1:2007
the lens!)
can be rotated 90° ; Grounding : Grounding clip for PCV system
- Read the operating instructions before attempting commissio­ning
- Installation, connection and adjustments should only be under­taken by specialist personnel
- Not a safety component in accordance with the EU Machinery Directive
Accessories
V19-G-5M-PUR-ABG
Female cordset, M12, 8-pin, shielded, PUR cable
VLX-MB2
Mounting bracket
VLX-MB1
Mounting bracket
PCV-USB-RS485-Converter Set
USB to RS 485 interface converter
ries can be found at
Approvals and certificates
CCC approval CCC approval / marking not required for products rated 36 V
Approvals CE
Notes
Measuring range
Start
measuring range
min
X
Measuring
range Z
Sensing range
max
X
-/+
Release date: 2017-10-05 14:01 Date of issue: 2018-03-06 284586-100001_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Loading...
+ 1 hidden pages