Laser light sensor VLD700-F280-2E2-1000
Function
The SmartRunner Detector performs high-precision area monitoring and switches as soon as
the smallest objects enter the field of detection. The detector is based on innovative SmartRunner technology and combines the light section method for detecting height profiles with a
2-D vision sensor. The light section method involves projecting a laser line onto an object. This
laser line is then detected by a camera at a specific angle. A height profile is then created
using the triangulation principle. This innovative laser technology provides reliable measurements on different surfaces.
Indicating / Operating means
Model Number
VLD700-F280-2E2-1000
Laser light sensor for field monitoring
Features
• Intelligent exposure time control
• Laser class 1, eyesafe
• Data Matrix control codes for parameterization
Laserlabel
1
2
3
READY
TEACH
RESULT
TRIGGER
4
Electrical connection
5
6
7
1
Pin Signal
1 IN Trigger
2 +UB
3 Data+ RS-485
4 Data- RS-485
5 Teach
6 Background
7 GND
8 Object
8
1 Ready
5
DIAGNOSE
POWER
BACKGROUND
OBJECT
6
7
8
2 Teach
3 Result
4 Trigger
5 Diagnose
6 Power
7 Background
8 Object
4
3
2
green/red
green/yellow
green/red
green/yellow
red
green
green
yellow
Release date: 2017-10-05 14:01 Date of issue: 2017-10-05 284586-100002_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Technical data
General specifications
Measurement range X = 40 ... 310 mm ; Z = 60 ... 700 mm
Light source laser diode
Light type red laser + Integrated LED lightning red 650 nm
Laser nominal ratings
Note VISIBLE LASER RADIATION , DO NOT STARE INTO BEAM
Laser class 1
Wave length Measurement laser: 660 nm
Pulse length Measurement laser: 2 ms
Maximum optical power output Measurement laser: 15 mW
Laser monitoring The safety system switches off the laser when the laser current
Object size > 0.1 mm at min. read distance
Scan rate 10 s
Functional safety related parameters
MTTFd 20 a
Mission Time (TM) 10 a
Diagnostic Coverage (DC) 0 %
Indicators/operating means
Operation indicator LED green
Diagnostics indicator LED yellow / red
Function indicator Trigger: LED yellow ; object in evaluation range : LED red / green
Control elements 2 push-buttons
Electrical specifications
Operating voltage UB24 V ± 20 % , PELV
No-load supply current I
Power consumption P0max. 6 W , Outputs without load
DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS
is too high
-1
max. 250 mA
0
1

VLD700-F280-2E2-1000Laser light sensor
Interface
Interface type RS 485 interface
Physical Switchable terminal resistor
Protocol binary code
Transfer rate 38400 ... 230400 Bit/s
Input
Input voltage 24 V
Number/Type External triggering + 1 Input
Switching threshold low: < 2.5 V, high: > 8 V
Output
Number/Type 2 digital outputs
Switching type PNP
Switching voltage 24 V
Switching current 150 mA each output
Ambient conditions
Operating temperature -20 ... 45 °C (-4 ... 113 °F) , (noncondensing; prevent icing on
Storage temperature -20 ... 70 °C (-4 ... 158 °F)
Mechanical specifications
Degree of protection IP67
Connection 8-pin, M12 x 1 connector ( supply + RS485 + Inputs/Outputs ) ;
Material
Housing PC/ABS
Optical face Plastic pane
Mass approx. 125 g
Tightening torque, fastening screws ≤ 2 Nm
General information
Note Security Instructions:
Compliance with standards and directives
Standard conformity
Noise immunity EN 61000-6-2:2005
Emitted inter ference EN 61000-6-4:2007/A1:2011
Degree of protection EN 60529
Shock and impact resistance EN 60068-2-27:2009
Laser class IEC 60825-1:2007
the lens!)
can be rotated 90° ; Grounding : Grounding clip for PCV system
- Read the operating instructions before attempting commissioning
- Installation, connection and adjustments should only be undertaken by specialist personnel
- Not a safety component in accordance with the EU Machinery
Directive
Accessories
V19-G-5M-PUR-ABG
Female cordset, M12, 8-pin, shielded,
PUR cable
VLX-MB1
Mounting bracket
VLX-MB2
Mounting bracket
PCV-USB-RS485-Converter Set
USB to RS 485 interface converter
ries can be found at
Approvals and certificates
CCC approval CCC approval / marking not required for products rated ≤36 V
Approvals CE
Notes
Measuring range
Start
measuring range
min
X
Measuring
range Z
Sensing range
max
X
-/+
Release date: 2017-10-05 14:01 Date of issue: 2017-10-05 284586-100002_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.