Pepperl Fuchs VAA-2E1A-PM-S Data Sheet

AS-Interface EMERGENCY STOP button VAA-2E1A-PM-S
Dimensions
33.6
SAFETY AT WORK
Model number
VAA-2E1A-PM-S
AS-Interface EMERGENCY STOP but­ton
• 2-channel, compelled connected
• Overload-protected in accordance with IEC 60947-5-5
• Integrated illumination in the actuator
• TÜV-approval for system components is available
• Biased actuator for self-monitoring
• EMERGENCY STOP unlocking by turning or pulling
Function
This AS-Interface emergency shutoff button is a two-channel, positively driven contact, allowing the operation of personnel protection systems when used according to specifica­tion along with an AS-Interface safety moni­tor. It occupies one complete address in the AS-Interface strand. When the safety monitor is properly configu­red, up to EN 954-1 Category 4 and IEC 61508 SIL 3 can be achieved. For mounting, this AS-Interface emergency shutoff button can be screwed into the front plate of the machine or the switch panel. The button can be illuminated in red. A designation plate and suitable connection cable are included in the scope of delivery.
Release date: 2018-01-24 15:48 Date of issue: 2018-01-24 192439_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
17.4 20.1
32 54.2
Electrical connection
AS-Interface
-+
BU
BN
Technical data
General specifications
Slave type Safety-Slave AS-Interface specification V2.1 Required master specification V2.0 UL File Number E198304
Functional safety related parameters
MTTFd 200 a B
1 E+5
10d
Electrical specifications
Rated operating voltage Ue26.5 ... 31.6 V from AS-Interface Rated operating current I Protection class III Insulation resistance 100 M
Input
Number/Type 2 NC
Supply from AS-Interface
Output
Number/Type LED red Supply from AS-Interface
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 62026-2:2013
Stand ar d co nf or mit y
Electromagnetic compatibility EN 62026-2:2013 Degree of protection EN 60529:2000 Electrical safety EN 60947-5-5:1997+A1:2005 AS-Interface EN 62026-2:2013 Functional safety EN 62061:2005
Programming instructions
Profile S-7.B.E. IO code 7 ID code B ID1 code F
40 mA
e
Safety function by positive opening in accordance with IEC/EN 60947-5-1 Reset by pulling
EN 61508 Parts 1-7:2010 NFPA 79:2007 EN 60204-1:2006
ø 40
1
ID2 code E Data bits (function via AS-Interface) input output
D0 dyn. safety code 1 OUT 1 D1 dyn. safety code 1 ­D2 dyn. safety code 2 ­D3 dyn. safety code 2 -
Parameter bits (programmable via AS-i) function
P0 not used P1 not used P2 not used P3 not used
Ambient conditions
Ambient temperature -25 ... 55 °C (-13 ... 131 °F) (no freezing) Storage temperature -40 ... 70 °C (-40 ... 158 °F) Relative humidity 40 ... 85 % , noncondensing
Mechanical specifications
Operating force Push: 32 N
Operating distance for positive opening operation: min. 4 mm
Degree of protection IP65 Connection Crimp terminal sockets (JST)
Installation Installation in 22 mm hole Mass 105 g Life span > 250,000 switching operations
Pull: 21 N Turn: 0.27 Nm Minimum for positive opening operation: 60 Nm
maximal: 4.5 mm
1.5 m Connecting cable with crimp on 2 flexible leads supplied with delivery
VAA-2E1A-PM-SAS-Interface EMERGENCY STOP button
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Release date: 2018-01-24 15:48 Date of issue: 2018-01-24 192439_eng.xml