Y connection cable V3-WM-BK0,6M-PUR-U-T-V1-G
Dimensions
L147.9
31.4
28
Model Number
V3-WM-BK0,6M-PUR-U-T-V1-G
Y connecting cable, M12 to 2 x M8, 3pin, PUR cable
Features
• Raw cable with cURus approval
• Simple assembling of 2 signals to one
M12 plug-in station
• Flame resistant cable
• Resistant to microbes and hydrolysis
• Immunity to vibration
• Suitable for drag chains
• Halogen-free
• Free from substances that impair
paint wetting
M12 x 1
31
1
Ø 4.2
2
3
L2
Technical data
General specifications
Number of pins 3
Connection 1 socket
Construction type 1 right angle
Threading 1 M8
Connection 2 socket
Construction type 2 right angle
Threading 2 M8
Connection 3 Male connector
Construction type 3 straight
Threading 3 M12
UL File Number E231213
Electrical specifications
Operating voltage UB48 V AC
Operating current I
Volume resistance < 5 mΩ
Ambient conditions
Ambient temperature -5 ... 80 °C (23 ... 176 °F) active
Pollution degree 3
Mechanical specifications
Degree of protection IP65 / IP68 / IP69K
Connection 1 x M12 connector, straight
Cable code Li 9Y 11Y 3 x 0.34
Material
Contacts CuSn
Contact surface Ni/Au
Connector TPU
Body TPU, black
Cable PUR
Slotted nut Zinc die-casting, nickel-plated
Sleeve connector Zinc die-casting, nickel-plated
Core insulation PP
Cable extra-fine wire, flexible
Sheath diameter Ø 4.3 mm
Bending radius > 10 x cable diameter, moving
Color black
Number of cores 3
Core cross-section 0.34 mm
Conductor construction 42 x 0.1 mm Ø
Length L 0.6 m
60 V DC
max. 4 A
B
-25 ... 80 °C (-13 ... 176 °F) static
2 x M8 socket, angled
> 5 x cable diameter, fixed
2
19.1
M8 x 1
10
Release date: 2019-01-22 09:17 Date of issue: 2019-05-23 299241_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Electrical connection
1
2
1
3
4
2
4
3
1
3
4
1
3
4
4
31
4
3S1S2 1
1
Drag chain suitability
Drag chain cycles ≥ 5000000
Motion velocity ≤ 3.3 m/s
Acceleration ≤ 5 m/s
Torsional stress ± 180 °/m
Flammability
Cable FT2
Compliance with standards and directives
Standard conformity
Flammability Body: UL 94
Halogen-free IEC 60754-1:1994
Approvals and certificates
UL approval UL Recognized General purpose
Maximum permissible operating voltage ≤ 60 V
Maximum permissible ambient tempera-
ture
2
Line: UL 1581 Section 1061; IEC 60332-1-2:2004
≤ 80 °C (≤ 176 °F)
V3-WM-BK0,6M-PUR-U-T-V1-GY connection cable
Release date: 2019-01-22 09:17 Date of issue: 2019-05-23 299241_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2