Pepperl Fuchs V3-WM-BK0.6M-PUR-U-T-V1-G Data Sheet

Y connection cable V3-WM-BK0,6M-PUR-U-T-V1-G
Dimensions
31.4
28
Model Number
V3-WM-BK0,6M-PUR-U-T-V1-G
Y connecting cable, M12 to 2 x M8, 3­pin, PUR cable
Features
• Raw cable with cURus approval
• Simple assembling of 2 signals to one M12 plug-in station
• Flame resistant cable
• Resistant to microbes and hydrolysis
• Immunity to vibration
• Suitable for drag chains
• Halogen-free
• Free from substances that impair paint wetting
M12 x 1
31
1
Ø 4.2
2
3
L2
Technical data
General specifications
Number of pins 3 Connection 1 socket Construction type 1 right angle Threading 1 M8 Connection 2 socket Construction type 2 right angle Threading 2 M8 Connection 3 Male connector Construction type 3 straight Threading 3 M12 UL File Number E231213
Electrical specifications
Operating voltage UB48 V AC
Operating current I Volume resistance < 5 m
Ambient conditions
Ambient temperature -5 ... 80 °C (23 ... 176 °F) active
Pollution degree 3
Mechanical specifications
Degree of protection IP65 / IP68 / IP69K Connection 1 x M12 connector, straight
Cable code Li 9Y 11Y 3 x 0.34 Material
Contacts CuSn Contact surface Ni/Au Connector TPU Body TPU, black Cable PUR Slotted nut Zinc die-casting, nickel-plated Sleeve connector Zinc die-casting, nickel-plated Core insulation PP
Cable extra-fine wire, flexible
Sheath diameter Ø 4.3 mm Bending radius > 10 x cable diameter, moving
Color black Number of cores 3 Core cross-section 0.34 mm Conductor construction 42 x 0.1 mm Ø Length L 0.6 m
60 V DC max. 4 A
B
-25 ... 80 °C (-13 ... 176 °F) static
2 x M8 socket, angled
> 5 x cable diameter, fixed
2
19.1
M8 x 1
10
Release date: 2019-01-22 09:17 Date of issue: 2019-05-23 299241_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Electrical connection
1
2
1
3
4
2
4
3
1
3
4
1
3
4
4
31
4
3S1S2 1
1
Drag chain suitability
Drag chain cycles 5000000 Motion velocity 3.3 m/s Acceleration 5 m/s Torsional stress ± 180 °/m
Flammability
Cable FT2
Compliance with standards and direc­tives
Standard conformity
Flammability Body: UL 94
Halogen-free IEC 60754-1:1994
Approvals and certificates
UL approval UL Recognized General purpose
Maximum permissible operating voltage 60 V Maximum permissible ambient tempera-
ture
2
Line: UL 1581 Section 1061; IEC 60332-1-2:2004
80 °C ( 176 °F)
V3-WM-BK0,6M-PUR-U-T-V1-GY connection cable
Release date: 2019-01-22 09:17 Date of issue: 2019-05-23 299241_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.