Female connector V31-GM-BK10M-PUR-U
Dimensions
Model Number
V31-GM-BK10M-PUR-U
Female cordset, M8, 4-pin, PUR cable
Features
• Raw cable with cURus approval
• Knurled nut suitable for tool assembly
• Immunity to vibration, with mechanical latching
• Flame resistant cable
• Resistant to microbes and hydrolysis
• Halogen-free
• Suitable for 2-, 3- and 4-wire technology
•Gold plated contacts
• Suitable for drag chains
32.8
10
M8 x 1
L
Technical data
General specifications
Number of pins 4
UL File Number E231213
Electrical specifications
Operating voltage UBmax. 30 V DC
Operating current I
Volume resistance < 5 mΩ
Ambient conditions
Ambient temperature Body: -40 ... 90 °C (-40 ... 194 °F)
Pollution degree 3
Mechanical specifications
Contact elements spring-loaded contact socket
Pin diameter 1 mm
Degree of protection IP67
Material
Contacts CuSn / Au
Contact surface Au
Body TPU, black
Cable PUR
Slotted nut Diecast zinc
Core insolation PP
Cable extra-fine wire, flexible
Sheath diameter Ø 4.3 mm
Bending radius > 10 x cable diameter, moving
Color black
Number of cores 4
Core cross-section 0.34 mm
Conductor construction 42 x 0.1 mm Ø
Length L 10 m
Drag chain suitability
Drag chain cycles ≥ 5000000 (at max. 60 °C)
Motion velocity ≤ 3.3 m/s
Torsional stress ± 180 °/m
Flammability
Contact carrier 94 HB
Housing 94 V-2
Cable FT2
Compliance with standards and directives
Standard conformity
Degree of protection EN 60529:2000
max. 3 A
B
cable, fixed: -40 ... 80 °C (-40 ... 176 °F)
cable, flexing: -20 ... 80 °C (-4 ... 176 °F)
> 5 x cable diameter, fixed
2
Release date: 2016-11-29 10:02 Date of issue: 2016-11-29 217852_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Electrical connection
42
31
1
2
3
4
BN
WH
BU
BK
1

Sta nda rd s IEC 61076-2-104:2008
Flammability Body: UL 94
Halogen-free IEC 60754-1:1994/DIN VDE 0472-815
Approvals and certificates
UL approval cURus AWM 20549 AWM I/II A/B 80°C 300V FT2 (cable)
Maximum permissible operating voltage ≤ 30 V
Maximum permissible ambient tempera-
ture
Line: UL 1581 Section 1061; IEC 60332-1-2:2004
≤ 80 °C (≤ 176 °F)
V31-GM-BK10M-PUR-UFemale connector
Release date: 2016-11-29 10:02 Date of issue: 2016-11-29 217852_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2