Pepperl Fuchs V1-W-OR1M-POC-V1-W Data Sheet

Connection cable V1-W-OR1M-POC-V1-W
Dimensions
Model Number
V1-W-OR1M-POC-V1-W
Connection cable, M12 to M12, 4-pin, TPE cable, welding-bead resistant
Features
• Resistant to welding bead formation
• Suitable for robotic applications / tor­sion resistant
• Does not give off silicone
• Ozone resistant
• Knurled nut suitable for tool assembly
• Immunity to vibration, with mechani­cal latching
• Gold-plated and machined contacts
• Protection degree IP67 / IP68 / IP69K
35.1
18.1
27.8
14.8
35.1
L
15.4
Technical data
General specifications
Number of pins 4 Connection 1 socket Construction type 1 right angle Threading 1 M12 Connection 2 Male connector Construction type 2 right angle Threading 2 M12
Electrical specifications
Operating voltage UBmax. 250 V AC/DC Operating current max. 4 A Contact resistance < 10 m
Ambient conditions
Ambient temperature Body: -40 ... 90 °C (-40 ... 194 °F)
Pollution Degree 3
Mechanical specifications
Contact elements spring-loaded contact socket Pin diameter 1 mm Protection degree IP67 / IP68 / IP69k Material
Contacts CuSn / Au Contact surface Au Body TPU, green Cable TPE resistant to welding bead formation Slotted nut Diecast zinc Sleeve connector Diecast zinc Core insolation ETFE
Cable fine-strand, flexible
Sheath diameter Ø 4.8 mm Bending radius > 10 x cable diameter, moving Color orange Cores 4 x 0.34 mm Conductor construction 19 x 0.16 mm Ø Length L 1 m
Flammability
Contact material 94 HB Housing 94 V-2 Cable flame-resistant
Cable, flexing:
-15 ... 120 °C (5 ... 248 °F) for 20000 h
-15 ... 150 °C (5 ... 302 °F) for 3000 h cable, fixed:
-40 ... 120 °C (-40 – 248°F) for 20000 h
-40 ... 150 °C (-40 ... 302 °F) for 3000 h
2
30.45
14.8
Release date: 2013-08-13 18:37 Date of issue: 2013-08-13 216709_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Electrical connection
1
4
2
3
1 2 3 4
1 2 3 4
1
2
4
3
1
Compliance with standards and direc­tives
Standard conformity
Protection degree EN 60529:2000 Sta nda rd s IEC 61076-2-101:2008 Flammability Body: UL 94
Line: UL 1581 Section 1061; IEC 60332-1-2:2004
V1-W-OR1M-POC-V1-WConnection cable
Release date: 2013-08-13 18:37 Date of issue: 2013-08-13 216709_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2