Y connection cable V1-W-E2-BK1M-PUR-A-T-V1-G
Dimensions
31.4
35.1
Model Number
V1-W-E2-BK1M-PUR-A-T-V1-G
Y connecting cable, M12 to 2xM12, 4­pin, PUR cable
Features
• Simple assembling of 2 signals to one M12 plug-in station
• Built-in LED, as operating and func­tion indicator
• Immunity to vibration, with mechani­cal latching
• Flame resistant cable
• Suitable for drag chains
• Improved resistance to weld slag
• Suitable for robotic applications / tor­sion resistant
• Halogen-free
• Resistant to microbes and hydrolysis
• Free of paint coating substances
M12 x 1
31
1
2
3
L2
Technical data
General specifications
Number of pins 4
Indicators/operating means
LED green Operating display LED yellow Functional display NO
Electrical specifications
Operating voltage UBmax. 24 V DC ± 15% Operating current I Contact resistance < 10 m Surge protection overvoltage category III
Ambient conditions
Ambient temperature Body: -40 ... 90 °C (-40 ... 194 °F)
Pollution Degree 3
Mechanical specifications
Contact elements spring-loaded contact socket Pin diameter 1 mm Degree of protection IP67 Connection 1 x M12 connector, straight
Material
Contacts CuSn / Au Contact surface Au Body TPU Cable PUR Slotted nut Diecast zinc Sleeve connector Diecast zinc Core insolation PP
Cable extra-fine wire, flexible
Sheath diameter Ø 4.3 mm Bending radius > 10 x cable diameter, moving
Color black Cores 4 x 0.34 mm Conductor construction 42 x 0.1 mm Ø Length L L1 = 0.3 m
Drag chain suitability
Drag chain cycles 5000000 (at max. 60 °C) Motion velocity 3.3 m/s Traverse distance 5 m horizontal Acceleration 5 m/s Torsion cycles 1000000 (at max. 60 °C)
max. 4 A
B
cable, fixed: -40 ... 80 °C (-40 ... 176 °F) cable, flexing: -25 ... 80 °C (-13 ... 176 °F)
2 x M12 right-angled sockets
> 5 x cable diameter, fixed
2
L2 = 0.3 m
2
27.8
M12 x 1
14.8
14.2
Release date: 2015-06-24 12:03 Date of issue: 2015-06-24 260171_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Electrical connection
1
2
4
3
1 2 3 4
1 2
13
3 4
1 2
2
3 4
1
42
3 1
42
3
1
Torsional stress ± 180 °/m
Flammability
Contact material 94 HB Housing 94 V-2 Cable FT2
Compliance with standards and direc­tives
Standard conformity
Degree of protection EN 60529:2000 Sta nda rd s IEC 61076-2-101:2008 Flammability Grip: UL 94
Halogen-free IEC 60754-1:1994/DIN VDE 0472-815
Cable: UL 758 / UL 1581