Female cordset, field attachable |
V1-G-Q2 |
|
|
|
|
<![endif]>Release date: 2018-03-22 11:19 Date of issue: 2018-03-22 198342_eng.xml
Model Number
V1-G-Q2
Field-attachable female QUICKONONE connector
Features
•Time-saving assembly with QUICKON-ONE technique
Function
It normally takes a lot of time to connect freely configurable M12 round connectors to the sensor cable. QUICKON can reduce this time to a minimum; the individual wire conductors do not have to be stripped anymore. For contacting, a blade contact cuts through the conductor insulation and applies contact to the wire strands. This contact is springloaded, vibration-proof and gas-tight.
The QUICKON M12 connector is available as a female or male 4-pin straight plug. In this way, individual sensor-actuator cables with several wires can be put together quickly and economically.
Dimensions
|
|
~ 52 |
|
<![if ! IE]> <![endif]>ø 14.8 |
<![if ! IE]> <![endif]>M12 x 1 |
<![if ! IE]> <![endif]>15 |
<![if ! IE]> <![endif]>ø 18.4 |
|
|
15 |
|
Technical data
General specifications
|
|
|
Number of pins |
|
4 |
Connection 1 |
|
socket |
Construction type 1 |
|
straight |
Threading 1 |
|
M12 |
UL File Number |
|
E191152 |
Electrical specifications |
|
|
Operating voltage |
UB |
max. 250 V |
Operating current |
IB |
max. 4 A |
Volume resistance |
|
< 5 mΩ |
Ambient conditions |
|
|
Ambient temperature |
|
-25 ... 80 °C (-13 ... 176 °F) |
Pollution degree |
|
3 |
Mechanical specifications |
|
|
Degree of protection |
|
IP65/IP67 |
Material |
|
|
Contacts |
|
CuSn |
Contact surface |
|
Ni/Au |
Body |
|
PA 66, black |
Slotted nut |
|
Zinc die-casting, nickel-plated |
Seal |
|
NBR |
Core insulation |
|
PVC/PE/PP |
Cable |
|
|
Sheath diameter |
|
4 ... 8 mm |
Cores |
|
Ø 1.3 ... 2.6 mm incl. insulation 2 |
|
|
Cross-section: 0.34 ... 0.75 mm |
|
|
Cable construction: Class 2-6 in accordance with VDE 0295 |
Mounting |
|
Max. tightening torque on the coupling nut: ≤ 1.2 Nm |
Flammability |
|
94 V-0 |
Note |
|
max. 10 connections possible to a cable of the same cross- |
|
|
section. After repeated cable connection it may be necessary to |
|
|
renew the seal and cap. |
Electrical connection
1
4 2
3
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. |
1 |
|