Pepperl Fuchs V19-G-2M-PUR-ABG-V19-G Data Sheet

Pepperl Fuchs V19-G-2M-PUR-ABG-V19-G Data Sheet

 

 

 

 

 

 

Connection cable

V19-G-2M-PUR-ABG-V19-G

 

 

 

 

<![if ! IE]>

<![endif]>Release date: 2018-03-15 11:24 Date of issue: 2018-03-15 242906_eng.xml

Dimensions

45

L

47.9

<![if ! IE]>

<![endif]>14.8

<![if ! IE]>

<![endif]>M12 x 1

<![if ! IE]>

<![endif]>M12 x 1

<![if ! IE]>

<![endif]>14.2

 

 

 

Technical data

 

 

 

 

 

General specifications

 

 

 

 

 

Number of pins

 

8 + shield

 

 

 

Connection 1

 

socket

Model Number

 

 

Construction type 1

 

straight

V19-G-2M-PUR-ABG-V19-G

 

Threading 1

 

M12

 

Connection 2

 

Male connector

Connecting cable, M12 to M12, PUR ca-

 

Construction type 2

 

straight

ble 8-pin, shielded

 

 

 

 

 

Threading 2

 

M12

 

 

 

Electrical specifications

 

 

Features

 

 

 

 

 

Operating voltage

UB

max. 30 V AC/DC

 

 

 

Operating current

IB

max. 2 A

• Knurled nut suitable for tool assembly

 

Characteristic impedance

 

100 Ω ± 15 Ω (> 1 MHz)

• Immunity to vibration, with mechani-

 

Ambient conditions

 

 

 

cal latching

 

Ambient temperature

 

-25 ... 70 °C (-13 ... 158 °F)

• Shield attached to coupling nut

 

 

 

 

 

Mechanical specifications

 

 

Gold plated contacts

 

Contact elements

 

spring-loaded contact socket

• Degree of protection IP67 / IP68 /

 

Pin diameter

 

1 mm

 

Degree of protection

 

IP67 / IP68 / IP69k

 

IP69K

 

Material

 

 

Halogen-free

 

Contacts

 

CuZn

 

Contact surface

 

Au

• Suitable for 2-, 3- and 4-wire technol-

 

 

 

Body

 

TPU, black

 

ogy

 

Cable

 

PUR

 

 

 

Slotted nut

 

Diecast zinc

 

 

 

Core insulation

 

Polyolefin

 

 

 

Cable

 

extra-fine wire, flexible

 

 

 

Sheath diameter

 

Ø 6.8 mm

 

 

 

Bending radius

 

> 7.5 x cable diameter

 

 

 

Color

 

grey

 

 

 

Cores

 

8 x 0.25 mm2

 

 

 

Conductor construction

 

19 x 0.127 mm Ø

 

 

 

Shield

 

grid

 

 

 

Length

L

2 m

 

 

 

Flammability

 

 

 

 

 

Contact carrier

 

94 HB

 

 

 

Housing

 

94 V-2

 

 

 

Cable

 

IEC 60332-1-2:2005

Electrical connection

 

 

 

 

 

 

 

1

1

 

 

 

 

1

2

2

8

1

 

7

3

3

7

6

8

4

4

2

 

6

2

5

5

 

5

3

6

6

3

 

5

7

7

4

 

4

8

8

 

 

 

 

 

 

 

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

 

 

 

 

 

1

 

 

 

 

 

 

Loading...