General specifications
Sensing range 200 ... 3000 mm Adjustment range 240 ... 3000 mm Dead band 0 ... 200 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 100 kHz Response delay 200 ms
Indicators/operating means
LED green Operating display LED yellow object in evaluation range LED red error
Electrical specifications
Model Number
UMC3000-30H-I-5M-FA
Single head system
Features
• Front of transducer and housing manufactured entirely from stainless steel
• Hygienic design, easy to clean
• Degree of protection IP68 / IP69K
• Programmable via DTM with PACTWARE
• Mounting bracket MH-30H-01-FA included in delivery
Description
Functional description
The enclosure and transducer of this ultrasonic sensor form a hermetically sealed unit. Due to its special design, this sensor is EHEDG compliant, and together with an appropriate fixture are especially suitable for applications where there are increased hygiene requirements, such as in the manufacture and handling of food. For reliable operation, due to the special design of this sensor, solely the enclosed mounting accessories must be used, even in applications without special hygiene requirements.
Diagrams
Characteristic response curve
Distance Y [m]
2.0
1.5
1.0
0.5
0.0
-0.5
-1.0
-1.5
-2.0 0 1 2 3 4 5
Y
flat surface 100 mm x 100 mm
X
round bar, Ø 25 mm
Distance X [m]
Operating voltage U No-load supply current I Time delay before availability t
Input/Output
Input/output type 1 synchronization connection, bidirectional
0 Level 0 ... 1 V 1 Level 4 V ... U Input impedance > 12 k Output rated operating current < 12 mA Pulse length 200 µs Pulse interval 2 ms
Synchronization frequency
Common mode operation 20 Hz Multiplex operation ≤ 20/n Hz, n = number of sensors n ≤ 10 (factory setting: 5 )
Input
Input type 1 program input Level (evaluation limit 1) 0 ... 1 V Level (evaluation limit 2) 3 V ... U Input impedance > 12 k Pulse length 2 ... 5 s
Output
Output type 1 analog output 4 ... 20 mA Resolution Evaluation range [mm]/3200, however 0.4 mm Deviation of the characteristic curve 0.2 % of full-scale value Repeat accuracy 0.1 % of full-scale value Load impedance 500 at UB 14V
Temperature influence 1.5 % of full-scale value
Ambient conditions
Ambient temperature -25 ... 60 °C (-13 ... 140 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type cable PUR , 5 m , With FDA approval Core cross-section 5 x 0.5 mm Degree of protection IP68 / IP69K Material
Housing stainless steel 1.4404 / AISI 316L
Transducer Stainless steel 1.4435 / AISI 316L
Mass 425 g
Factory settings
Output evaluation limit A1: 240 mm
General information
Supplementary information Switch settings of the external programming adapter:
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007+A1:2012
Approvals and certificates
CCC approval CCC approval / marking not required for products rated 36 V EHEDG Type EL Class I AUX ECOLAB yes
B
0
v
10 ... 30 V DC
50 mA 400 ms
B
B
300 at U
LED window: VMQ Elastosil LR 3003/Shore 50 A
evaluation limit A2: 3000 mm output function: rising ramp
"output load": pull-down "output logic": noninv
FDA: All materials used for the sensor comply with CFR, title 21, §177.2600 (FDA)
IEC 60947-5-2:2007 + A1:2012 EN 60947-5-7:2003 IEC 60947-5-7:2003
B
2
< 14V
Release date: 2016-03-01 11:55 Date of issue: 2017-03-21 217779_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Ultrasonic sensor UMC3000-30H-I-5M-FA
Dimensions
ø 28
ø 30
11 3.5
Electrical Connection
100
BN
WH
GY
BK
BU
3.5 11
+U
B
Program input
Syncronization
Output
-U
B
ø 6.3
Additional Information
Programming the evaluation limits
Rising ramp A1 < A2:
A1
Falling ramp A2 < A1:
A2
Zero line
Blind area
A1 = 0 mm
Object distance
A2
A1
A2
Accessories
UC-PROG1-USB
Programming adapter
V15S-G-0,3M-PUR-WAGO
Male cordset, M12, 5-pin, PUR cable with WAGO terminals
MH-30H-01-FA
Mounting aid, 30 mm acc. to EHEDG
Mounting
Comply with the minimum permissible bending radius of 70 mm, if you install the connecting cable!
For reliable operation, you must use the included sensor mounting aid. This also applies for ap­plications without special hygiene requirements.
Cleaning the Sensor in Areas with Hygiene Requirements
The sensor may only be used with the mounting aid included in the scope of delivery as the fixture. Please note the information in the enclosed package insert for the mounting aid with regard to the correct position of the seals and the correct process for tightening the screw connections.
If the sensor as a whole is located in an area subject to hygiene requirements, the sensor must be accessible from all sides for cleaning purposes. If the sensor is fitted with only the front in an area subject to hygiene requirements, the front must be ac­cessible from all sides accordingly.
The sensor and corresponding fixture are certified by ECOLAB. The components were subjected to the cleaning agents listed in the certificate and are resistant to the­se agents. Use of other cleaning agents and chemicals is also possible. However, to ensure the sensor and fixture offer resistance to these substances, corresponding tests must be performed by the user.
For cleaning purposes, as a general rule you can completely cover the sensor inclu­ding the fixture with foam and clean using a water jet. Cleaning at elevated tempera­tures of up to 85 °C is possible. It is not permitted to use high-pressure cleaning equipment for cleaning purposes in areas subject to hygiene requirements.
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.