Sensing range 20 ... 60 mm , optimal distance: 45 mm Transducer frequency 395 kHz
LED green indication: single sheet detected LED yellow Indication: No sheet detected (Air) LED red indication: double sheet detected
Electrical specifications
Model Number
UDC-18GM50-400-3E0
Features
• Ultrasonic system for reliable detection of no, one, or two overlapping sheet materials, preferably papers
• Short version
• No TEACH-IN required
• Function indicators visible from all directions
• Insensitive to printing, colors, and shining surfaces
2
• Material weight from 10 g/m over 2000 g/m
2
• Very wide material spectrum, finest papers up to thin sheet metals as well as plastic- and metal foils
• Perpendicular or inclined sensor mounting relative to the sheet plane possible
up to
Operating voltage U No-load supply current I Time delay before availability t
Input
Input type Function input
Pulse length 100 ms Impedance 4 k
Output
Output type 3 switch outputs NPN, NO Rated operating current I Voltage drop U Switch-on delay t Switch-off delay t Pulse extension min. 120 ms programmable
Ambient conditions
Ambient temperature 0 ... 60 °C (32 ... 140 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type cable PVC , 2 m Core cross-section 0.14 mm Degree of protection IP67 Material
Housing nickel plated brass; plastic components: PBT Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam
Mass 135 g
General information
Supplementary information Switch settings of the external programming adapter:
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007+A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose, Class 2 Power Source CSA approval cCSAus Listed, General Purpose, Class 2 Power Source CCC approval CCC approval / marking not required for products rated 36 V
B
0
v
e
d
on
off
18 ... 30 V DC , ripple 10 % < 50 mA < 500 ms
0-level: -U 1-level: +U
3 x 100 mA , short-circuit/overload protected 3 V approx. 15 ms (shorter response time on request) approx. 15 ms (shorter response time on request)
"output load": pull-up "output logic": inv
IEC 60947-5-2:2007 + A1:2012
... -UB + 1V
B
- 1 V ... +U
B
2
SS
B
Diagrams
Mounting/Adjustment
Recommended distances
a
= 5 ... 15 mm
b
10 mm
d
= 40 ... 45 mm
d
a
Release date: 2017-09-07 16:17 Date of issue: 2017-09-07 191326_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
b
1
Double sheet sensor UDC-18GM50-400-3E0
Dimensions
wires 70 mm with wire end ferrules
l = 2 m
l = 0.5 m
ø 15
70
LEDs
500
Additional Information
Mounting/Adjustment
Evaluation unit with receiver unit
4
24
M18 x 1
30
50
53
Emitter unit
24
M18 x 1
22
(for very thick papers)
b
β
a
Angular misalignment
< +/- 1°
α
Sensor offset
s < +/- 1 mm
β = 35˚
d
α
s
Electrical Connection
Standard symbol/Connection:
Double sheet control
(BN)
(PK)
(WH)
(BK)
U
(GY)
(BU)
Accessories
UC-PROG1-USB
Programming adapter
MH-UDB01
Mounting bracket for double sheet monitor
UDB-Cable-2M
+U
B
Function input
Output single sheet
Output double sheet
Output air
-U
B
UDB-Cable-1M
PACTware 4.1
FDT Framework
Ultraschall-Sensoren DTM
DTM devices for communication with cube style and UMC... sensors
V15S-G-0,3M-PUR-WAGO
Male cordset, M12, 5-pin, PUR cable with WAGO terminals
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Release date: 2017-09-07 16:17 Date of issue: 2017-09-07 191326_eng.xml