Ultrasonic sensor UCC1000-30GM-E6R2-V15
Technical data
General specifications
Sensing range 80 ... 1000 mm
Adjustment range 120 ... 1000 mm
Dead band 0 ... 80 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 175 kHz
Model Number
UCC1000-30GM-E6R2-V15
Single head system
Features
• High chemical resistance through
PTFE coated transducer surface
• Parameterization interface for the
application-specific adjustment of
the sensor setting via the service
program ULTRA 3000
• 2 programmable switch outputs
• Hysteresis mode selectable
• Window mode selectable
• Synchronization options
• Adjustable acoustic power and
sensitivity
• Temperature compensation
Diagrams
Characteristic response curves
1
Angle [degrees]
30
20
10
0
-10
-20
-30
90 80 70 60 50 40
0.0
0.5
1.0
1.5
Distance [m]
Curve 1: flat plate 100 mm x 100 mm
Curve 2: round bar, Ø 25 mm
2
2.0 2.5 3.0
Response delay 65 ms minimum
Indicators/operating means
LED green solid: Power-on
LED yellow 1 solid: switching state switch output 1
LED yellow 2 solid: switching state switch output 2
LED red solid: temperature/program plug not connected
Temperature/TEACH-IN connector Temperature compensation , Switch points programming ,
Electrical specifications
Operating voltage U
No-load supply current I
Interface
Interface type RS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit
Input/Output
Synchronization bi-directional
Synchronization frequency
Common mode operation ≤ 30 Hz
Multiplex operation ≤ 30 Hz / n , n = number of sensors , n ≤ 5
Output
Output type 2 switch outputs PNP, NO/NC, programmable
Rated operating current I
Voltage drop U
Repeat accuracy ≤ 0.1 % of full-scale value
Switching frequency f ≤ 2.5 Hz
Range hysteresis H 1 % of the adjusted operating range (default settings),
Temperature influence ≤ 2 % from full-scale value (with temperature compensation)
Ambient conditions
Ambient temperature 0 ... 70 °C (32 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 5-pin
Degree of protection IP65
Material
Housing Stainless steel 1.4305 / AISI 303
Transducer PTFE (diaphragm surface)
Mass 140 g
Factory settings
Output 1 Switching point: 120 mm
Output 2 Switching point: 1000 mm
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
B
0
e
d
195 ms factory setting
flashing: Standby mode or program function object detected
flashing: program function
flashing: program function
flashing: fault or program function object not detected
output function setting
10 ... 30 V DC , ripple 10 %
≤ 50 mA
0 level -U
1 level: +4 V...+U
input impedance: > 12 KOhm
synchronization pulse: ≥ 100 µs, synchronization interpulse
period: ≥ 2 ms
200 mA , short-circuit/overload protected
≤ 2.5 V
programmable
≤ 0.2 %/K (without temperature compensation)
O-ring for cover seal: Viton
output function: Switch point operation mode
output behavior: NO contact
output function: Switch point operation mode
output behavior: NO contact
IEC 60947-5-2:2007 + A1:2012
...+1 V
B
SS
B
Release date: 2016-04-25 09:38 Date of issue: 2016-04-25 120334_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1

Ultrasonic sensor UCC1000-30GM-E6R2-V15
Dimensions
Additional Information
ø32
13.5
5
36
M30x1.5
96
LED
Temperature probe
Coded plug
Possible operating modes
1. Switch point mode
When A1 < A2, both switch outputs are activated as
N. O. co ntac ts.
Switch point 1
A 1 (N.O.)
Switch output 1
A 2 (N.O.)
Switch output 2
When A1 > A2, both switch outputs are activated as
N.C. contacts.
A 1 (N.C.)
Switch output 1
A2 (N.C.)
Switch output 2
2. Window mode
To exchange the switching distances is of no effect.
A 1 (N.O.)
Switch output 1
A2 (N.C.)
Switch output 2
3. Latching mode
To exchange the switching distances is of no effect.
A 1 (N.O.)
Switch output 1
A2 (N.C.)
Switch output 2
Switch point 2
Electrical Connection
Standard symbol/Connection:
(version E6, pnp)
Core colors in accordance with EN 60947-5-2.
(BN)
1
(GY)
5
(WH)
2
(BK)
4
(BU)
3
+ UB
Sync.
Switch output 1
Switch output 2
- UB
Pinout
Connector V15
2
1
3
5
4
Accessories
BF 30
Mounting flange, 30 mm
BF 5-30
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm
UC-30GM-PROG
ULTRA3000
Software for ultrasonic sensors, comfort line
UC-30GM-R2
V15-G-2M-PVC
Female cordset, M12, 5-pin, PVC cable
Description of Sensor Functions
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Release date: 2016-04-25 09:38 Date of issue: 2016-04-25 120334_eng.xml