General specifications
Sensing range 45 ... 500 mm Adjustment range 50 ... 500 mm Dead band 0 ... 45 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 300 kHz Response delay 60 ms
Nominal ratings
Temperature drift ± 1.5 % of full-scale value
Model Number
UC500-30GM70S-IE2R2-V15
Ultrasonic diffuse sensor with pivoting transducer
Features
• Analog output 4 ... 20 mA
•1 switch output
• Synchronization options
• Temperature compensation
• Can be parameterized via the ULT­RA-PROG-IR software and inter­face (accessories)
Diagrams
Characteristic response curve
Distance Y [mm]
200
100
0
-100
-200 0 100 200 300 400 500 600 700 800 900
Y
Curve 1: flat surface 100 mm x 100 mm Curve 2: round bar, Ø 25 mm
2
X
1
Distance X [mm]
Time delay before availability t
Limit data
Permissible cable length max. 300 m
Indicators/operating means
LED yellow switching state switch output LED green/yellow yellow: object in evaluation range
Potentiometer switch output adjustable
Electrical specifications
Rated operating voltage U Operating voltage U Ripple 10 % No-load supply current I
Interface
Interface type Infrared Mode point-to-point connection
Input/Output
Input/output type 1 synchronization connection, bidirectional ( Factory setting:
0 Level 3 V 1 Level 15 V Input impedance typ. 900 Number of sensors max. 10
Switching output
Output type 1 switch output PNP, NO ( NC contact programmable ) Default setting 50 ... 500 mm ( adjustable via potentiometer ) Repeat accuracy R ± 0.5 mm Operating current I Switching frequency 5 Hz Switching hysteresis 5 mm ( programmable ) Voltage drop 3 V Off-state current 10 µA
Analog output
Output type 1 current output 4 ... 20 mA , ascending/descending
Default setting rising ramp ; evaluation limit A1: 50 mm ; evaluation limit A2:
Load resistor 500
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F) Shock resistance 30 g , 11 ms period Vibration resistance 10 ... 55 Hz , Amplitude ± 1 mm
Mechanical specifications
Connection type Connector M12 x 1 , 5-pin Degree of protection IP65 Material
Housing brass, nickel-plated
Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam Installation position any position Mass 170 g Construction type Cylindrical
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
B
L
v
e
0
85 ms
green: Teach-In
24 V DC 20 ... 30 V DC (including ripple)
50 mA
synchronized mode ) / Teach-In input
300 mA , short-circuit/overload protected
programmable
500 mm
IEC 60947-5-2:2007 + A1:2012 EN 60947-5-7:2003 IEC 60947-5-7:2003
Release date: 2016-02-12 15:23 Date of issue: 2016-02-12 238395_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated
36 V
1
Ultrasonic sensor UC500-30GM70S-IE2R2-V15
Dimensions
M30 x 1.5
M12 x 1
10.5 88.5
126
74.4
Additional Information
Analog output operating mode
Rising ramp
Evaluation limit A1
Blind zone
2818
61
Evaluation range
Evaluation limit A2
Switching output operating mode
Window operation mode
Blind zone
switching
point 1
switching
point 2
h2h1
Electrical Connection
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK 5 GY
1
2
4
5
3
2
1
3
(brown) (white) (blue) (black) (gray)
L+
XI
Switch output
Analog output
L-
5
4
Release date: 2016-02-12 15:23 Date of issue: 2016-02-12 238395_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Loading...
+ 2 hidden pages